Schneider Electric ATS480C66Y Altistart 480 Soft Starter, 660A, 208-690V AC, 51.4kg

  • MPN: ATS480C66Y
  • PPN: SCH-ATS480C66Y
Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 660A in normal duty, it supplies motor from 160kW to 630kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 400mm (width) x 314mm (depth) x 670mm (height) and it weighs 51,4kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, China, France, Indonesia, United States
Depth314.0 mm

Communications & Management Attributes

Communication Data Link
serial
Communication Port ProtocolModbus serial

Complementary Attributes

Maximum Horse Power Rating
500.0 hp 575 V heavy duty200.0 hp 208 V normal duty250.0 hp 230 V normal duty, 200.0 hp 230 V heavy duty500.0 hp 460 V normal duty, 400.0 hp 460 V heavy duty600.0 hp 575 V normal duty
Integrated Motor Overload Protection
true
Minimum Switching Current
100 mA 12 V DC relay outputs
Maximum Switching Currentrelay outputs, relay outputs 2 A 250 V ACrelay outputs 2 A 30 V DC
Maximum Permanent Current590.0 A at 40 °C heavy duty

Important Information Attributes

Persona Type Ids
EU, OM, OM8
Device Connection
in the motor supply line, to the motor delta terminals
Function Available
external bypass control, pre-heating, smoke extraction, multi-motor cascade, second motor set, user management, ports and services hardening, security event logging, cybersecure firmware update, single direction
Motor Power Kw
355.0 kW 440 V in the motor supply line heavy duty560.0 kW 690 V in the motor supply line heavy duty400.0 kW 400 V to the motor delta terminals heavy duty, 160.0 kW 230 V in the motor supply line heavy duty, 355.0 kW 400 V in the motor supply line normal duty, 315.0 kW 400 V in the motor supply line heavy duty400.0 kW 440 V in the motor supply line normal duty, 400.0 kW 500 V in the motor supply line heavy duty, 400.0 kW 525 V in the motor supply line heavy duty630.0 kW 660 V in the motor supply line normal duty, 560.0 kW 660 V in the motor supply line heavy duty, 630.0 kW 690 V in the motor supply line normal duty, 315.0 kW 230 V to the motor delta terminals normal duty, 500.0 kW 400 V to the motor delta terminals normal duty
Protection Type
line supply phase loss motorthermal protection motor, phase failure lineintegrated thermal protection motorthermal protection starter, current overload motor, underload motor, excessive starting time, locked rotor motor, motor phase loss motor, line supply phase loss line
Certificate Agency
CE, cULus, CCC, UKCA, RCM, EAC, DNV, ABS, BV, CCS
Environmental Class (During Operation)
class 3C3 according to IEC 60721-3-3, class 3S2 according to IEC 60721-3-3
Maximum Acceleration Under Vibratory Load (During Transport)
15 m/s² at 200...500 Hz, 10 m/s² at 9...200 Hz
Carbon Footprint Of The End-of-life Phase [C1 To C4]
6.7739, 7 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
496 kg CO2 eq., 495.73
Local Data Status
Publishable
Pre Comm Date
2021-12-20
Stocking Flag
N
Device Type
Soft starter - Soft starter
Traceability
Yes
Average Life Duration
10 year(s)
Distribution Carbon Footprint
7.7413
Use Carbon Footprint
46269
Weee Applicability
Finished product
Weee Product Category
4
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant By Exemption
Rohs Eur Full Compliance Status
Compliant By Exemption
China Rohs Label
5
Without Single Use Plastic
No
Dangerous Goods Code
LITHIUM METAL BATTERIES IN EQUIP. BUTTON CELL-BAT EXEMPT
Tier
1
Function Option
Standard
Market Segmentation
Industrial
Apparent Power
0.125 kVA
Data Format
8 bits, configurable odd, even or no parity
Display Screen Available
true
Network Frequency
50/60 Hz
Number Of Addresses
0-227 Modbus serial
Phase
3 phase
Power Loss Static Current Independent
25.0 W
Product Destination
asynchronous motors
Product Specific Application
process and infrastructures
Returnability
Yes
Supply Frequency
50...60 Hz - 20...20 %
Total Lifecycle Carbon Footprint
46 787 kg CO2 eq.
Transmission Rate
1200...256000 bit/s
Updatability
Upgradeable through digital modules
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Torque Control
true
Database Version
2020-12
Pcr Version
PCR-ed3-EN-2015 04 02
Data Source
referent product
Functional-unit Quantity
1
Reference Lifetime In Y
10
Energy Model - Manufacturing [A1-a3]
Energy model used: China
Energy Model - Use [B6]
Electricity Mix; AC; < 1kV; EU-27
Recyclability Potential In %
87
Width Nominal
400.0 mm
[Uc] Control Circuit Voltage
24 V DC110...230 V AC 50/60 Hz - 15...10 %
[Uimp] Rated Impulse Withstand Voltage
6 kV
Maximum Acceleration Under Shock Impact (During Operation)
150 m/s² at 11 ms
Maximum Acceleration Under Shock Load (During Transport)
100 m/s² at 11 ms
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load (During Transport)
1.75 mm at 2...9 Hz
With Safety Function Safe Direction (Sdi)
false
With Safety Function Safe Position (Sp)
false
With Safety Function Safe Stop 1 (Ss1)
false
With Safety Function Safely Limited Position (Slp)
false
With Sft Fct Safe Stop 2 (Ss2)
false
Nbr. Of Units In Pkg.
1
Take-back
No
Acidification Of Soil And Water (Kg.Equivalent.So2) Total Life Cycle
351.77
Acidification Of Soil And Water (Kg.Equivalent.So2) Operational Energy Use [B6]
349.9
Air Pollution (M3) Manufacturing [A1-a3]
76874
Air Pollution (M3) Installation [A5]
194.65
Air Pollution (M3) End Of Life [C1-c4]
502.07
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3]
5738.2
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Installation [A5]
11.049
Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4]
56.919
Exported Energy (Mj By Energy Vector) Installation [A5]
4.4505
Global Warming (Kg.Equivalent.Co2) Manufacturing [A1-a3]
495.73
Global Warming (Kg.Equivalent.Co2) Installation [A5]
7.8839
Global Warming (Kg.Equivalent.Co2) End Of Life [C1-c4]
6.7739
Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3]
1637.4
Materials For Recycling (Kg) Total Life Cycle
51.452
Materials For Recycling (Kg) Installation [A5]
6.4741
Net Use Of Fresh Water (M3) Total Life Cycle
134.47
Net Use Of Fresh Water (M3) Operational Energy Use [B6]
120.68
Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3]
283.05
Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6]
173070
Photochemical Ozone Formation (Kg.Equivalent.C2h4) Operational Energy Use [B6]
16.538
Radioactive Waste Disposed Of (Kg) Operational Energy Use [B6]
141.08
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3]
9657
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Installation [A5]
11.668
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4]
71.221
Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3]
10061
Total Use Of Primary Energy During The Life Cycle (Mj) Installation [A5]
11.857
Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4]
71.299
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3]
403.96
Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
160.23
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
880000
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4]
109.31
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6]
870310
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
235.33
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
67242
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6]
67073
Use Of Secondary Materials (Kg) Manufacturing [A1-a3]
14.586
Water Eutrophication (Kg.Equivalent.P04 3-) Operational Energy Use [B6]
13.116
Water Pollution (M3) Manufacturing [A1-a3]
49562
Water Pollution (M3) Installation [A5]
123.38
Water Pollution (M3) End Of Life [C1-c4]
959
Customs Code
8537109170
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder
Electromagnetic Compatibilityconducted and radiated emissions level A conforming to IEC 60947-4-2conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2, damped oscillating waves level 3 conforming to IEC 61000-4-12electrostatic discharge level 3 conforming to IEC 61000-4-11, immunity to electrical transients level 4 conforming to IEC 61000-4-4immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3voltage/current impulse level 3 conforming to IEC 61000-4-5
MarkingCE, CCC, UKCA, EAC, RCM, cULus
Option Cardcommunication module Profibus DP V1, communication module Modbus TCP/EtherNet/IP, communication module CANopen daisy chain, communication module CANopen Sub-D, communication module CANopen open style, communication module PROFINET
Utilisation CategoryAC-3A, AC-53A
[Ue] Rated Operational Voltage440 V 355.0 kW in the motor supply line heavy duty690 V 560.0 kW in the motor supply line heavy duty, 230 V 200.0 hp heavy duty575 V 500.0 hp heavy duty, 230 V 160.0 kW in the motor supply line heavy duty, 400 V 355.0 kW in the motor supply line normal duty, 400 V 315.0 kW in the motor supply line heavy duty440 V 400.0 kW in the motor supply line normal duty, 500 V 400.0 kW in the motor supply line heavy duty, 525 V 400.0 kW in the motor supply line heavy duty660 V 630.0 kW in the motor supply line normal duty, 660 V 560.0 kW in the motor supply line heavy duty, 690 V 630.0 kW in the motor supply line normal duty208 V 200.0 hp normal duty, 230 V 250.0 hp normal duty460 V 500.0 hp normal duty, 460 V 400.0 hp heavy duty575 V 600.0 hp normal duty
Maximum Acceleration Under Vibratory Load (During Storage)15 m/s² at 200...500 Hz, 10 m/s² at 9...200 Hz
Carbon Footprint Of The Distribution Phase [A4]7.7413, 8 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]8 kg CO2 eq., 7.8839
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]46 269 kg CO2 eq., 46269
Local Publishable Date2026-01-12
Return IndicatorY
Stock Policy2
ServiceabilityYes
Field Service DivisionIDIBS
Manufacturing Carbon Footprint495.73
Installation Carbon Footprint7.8839
End Of Life Carbon Footprint6.7739
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI2102013EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeNo
Rohs Eur Conformity Date2149
China Rohs In ScopeYes
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier Id1
Function Option IdSTANDARD
Market Segmentation IdINDUSTRIAL
Product Kit IdentifierN
Connector Type1 RJ45
Device Short NameATS480
Method Of Accessslave Modbus serial
Noise Level55.0 dB
Operating Positionvertical +/- 10 degree
Power Loss Per Device Current Dependent1938.0 W
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typesoft starter
Range Of ProductAltivar Soft Starter ATS480
Software VersionEIME v5.9.1
Sustainable PackagingNo
Transmission FrameRTU
Type Of Polarizationno impedance Modbus serial
Volume Of Cooling Air600.0 m3/h
With Safety Function Safe Programmable Logicfalse
Pep CodeENVPEP2102013EN
Pep Verification Date2021-11-01
Type Of Verification For The PepIndependent external review
Functional-unit DescriptionThe aim of soft starter is to drive an asynchronous motor (squirrel cage) by limitation of the current during acceleration and deceleration phase with a torque control. It’s based on three phases dimmer with Silicon controlled rectifier (thyristor). The rating of softstarter is given by nominal current 660 A in the case study which lead to drive several power motor depending of power network ie 230V power motor of 110kW and 690V power motor of 355kW. Calculation of the environmental impacts is based on 10 years of product service lifetime. The usage profile taken into account is 45% uptime in use phase, 45% uptime in stand by phase and 10% uptime in off phase.
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh78366.96
Energy Model - Installation [A5]Electricity Mix; AC; < 1kV; EU-27
Energy Model - End Of Life [C1-c4]Electricity Mix; AC; < 1kV; EU-27
Height Nominal670.0 mm
[Ie] Rated Operational Currentnormal duty 660.0 A 40 °C)
[Ui] Rated Insulation Voltage690 V
[Us] Rated Supply Voltage208...690 V - 15...10 %
Maximum Acceleration Under Shock Load (During Storage)100 m/s² at 11 ms
Maximum Acceleration Under Vibrational Stress (During Operation)10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load (During Storage)1.75 mm at 2...9 Hz
With Safety Function Safe Brake Management (Sbc/Sbt)false
With Safety Function Safe Operating Stop (Sos)false
With Safety Function Safe Speed Monitor (Ssm)false
With Safety Function Safe Torque Off (Sto)false
With Safety Function Safely Limited Speed (Sls)false
Carbon Footprint (Kg Co2 Eq Total Life Cycle)46787
Package Weight(Lbs)63.0 kg
Warranty (In Months)18
Acidification Of Soil And Water (Kg.Equivalent.So2) Manufacturing [A1-a3]1.816
Air Pollution (M3) Total Life Cycle2062200
Air Pollution (M3) Distribution [A4]329.31
Air Pollution (M3) Operational Energy Use [B6]1984300
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle482540
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4]108.76
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6]476630
Exported Energy (Mj By Energy Vector) Total Life Cycle5.0388
Global Warming (Kg.Equivalent.Co2) Total Life Cycle46787
Global Warming (Kg.Equivalent.Co2) Distribution [A4]7.7413
Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6]46269
Hazardous Waste Disposed Of (Kg) Total Life Cycle1692.1
Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4]54.733
Materials For Recycling (Kg) Manufacturing [A1-a3]4.2416
Materials For Recycling (Kg) End Of Life [C1-c4]40.736
Net Use Of Fresh Water (M3) Manufacturing [A1-a3]13.78
Non-hazardous Waste Disposed Of (Kg) Total Life Cycle173360
Non-hazardous Waste Disposed Of (Kg) Installation [A5]6.2603
Photochemical Ozone Formation (Kg.Equivalent.C2h4) Total Life Cycle16.685
Radioactive Waste Disposed Of (Kg) Total Life Cycle141.29
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle880160
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Distribution [A4]109.31
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6]870310
Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle947630
Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4]109.46
Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6]937380
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle67477
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6]67073
Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]160.23
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]9496.8
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Installation [A5]11.668
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4]71.221
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]235.33
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]168.63
Use Of Secondary Materials (Kg) Total Life Cycle14.586
Water Eutrophication (Kg.Equivalent.P04 3-) Total Life Cycle13.462
Water Pollution (M3) Total Life Cycle1993400
Water Pollution (M3) Distribution [A4]1273
Water Pollution (M3) Operational Energy Use [B6]1941500
[In] Rated Current Pwr Loss Specifctn2660.0 A

Environment Attributes Main

Ambient Air Temperature For Operation
-15-40 °C (without derating), -15-40 °C (without derating), 40-60 °C (with current derating of 2 % per °C), -15-40 °C (without derating), -15-40 °C (without derating)
Operating Altitude
<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m, > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m<= 3280.84 ft (1000 m) without derating, <= 3280.84 ft (1000 m) without derating, > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m, > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Circularity Profile
ENVEOLI2102013EN
Eu Rohs Directive
Compliant By Exemption
Packaging Made With Recycled Cardboard
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Code
ENVPEP2102013EN
Pcr Version
PCR-ed3-EN-2015 04 02
Ambient Air Temperature For Storage-25-70 °C, -25-70 °C
Take BackNo
China Rohs RegulationX
Carbon Footprint46787
Environmental DisclosureENVPEP2102013EN
Ip Degree Of ProtectionIP00
Packaging Without Single Use PlasticNo
Relative Humidity0-95 % without condensation or dripping water IEC 60068-2-3
Pep Verification Date2021-11-01
Type Of Verification For The PepIndependent external review

General Attributes

Phase
3 phase
Range Of Product
Altivar Soft Starter ATS480
Product Or Component Typesoft starter

ETIM

ETIM 8
EC000640
ETIM 9EC000640

Output Attributes

Discrete Output Type
DQ1) programmable digital output <= 30 V, DQ2) programmable digital output <= 30 V
Analogue Output Number
1
Discrete Output Number
2
Output Current Drift
150-700 %
Relay Output Typerelay outputs R1A 1 NO, relay outputs R1B 1 NOrelay outputs RIC NO/NC programmable
Analogue Output Typecurrent output AQ1 0...20 mA or 0...10 V 500 Ohm
Output Compatibilityopen collector level 1 PLC IEC 65A-68
Relay Output Number3

Input Attributes

Analogue Input Type
AI1/PTC PTC/Pt 100 temperature probe, PTC2 PTC/Pt 100 temperature probe, PTC3 PTC/Pt 100 temperature probe
Input Compatibility
STOP discrete input level 1 PLC IEC 61131-2, RUN discrete input level 1 PLC IEC 61131-2, DI3 discrete input level 1 PLC IEC 61131-2, DI4 discrete input level 1 PLC IEC 61131-2
Discrete Input Logic
programmable digital input < 5 V
Discrete Input TypeSTOP) logic inputs, 3500 Ohm, RUN) logic inputs, 3500 OhmDI3) programmable as logic input, 3500 Ohm, DI4) programmable as logic input, 3500 Ohm
Analogue Input Number1
Discrete Input Number4

Batteries & Runtime Attributes

Removable Battery
Yes