Schneider Electric LC1F185X7 contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A, coil 600V AC


Schneider Electric LC1F185X7 contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A, coil 600V AC
- MPN: LC1F185X7
- PPN: SCH-LC1F185X7
- UNSPSC: 39121529
Spec sheet
Loading compare button...
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To view product inventory
CAD$2071.02/ EA
Description
contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A, coil 600V AC
Specifications
Complementary
- Product Certifications
- LROS (Lloyds register of shipping) || RMRoS || UL || BV || RINA || CSA || DNV || ABS || CB
- Average Impedance
- 0.33 mOhm - Ith 275 A 50 Hz
- Control Circuit Voltage Limits
- operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.2...0.55 Uc 40...400 Hz 55 °C)
- Mounting Support
- plate
- Contactor Coil Voltage
- 600 V AC standard
- Power Range
- 30-50 kW 200-240 V 3 phase || 55-100 kW 200-240 V 3 phase || 55-100 kW 380-440 V 3 phase || 55-100 kW 480-500 V 3 phase || 110-220 kW 480-500 V 3 phase
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Connections - Terminals
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bar 2 25 x 3 mm || power circuit lugs-ring terminals 1 150-150 mm² || power circuit connector 1 150-150 mm² || power circuit bolted connection
- Motor Starter Type
- direct on-line contactor
- Maximum Operating Rate
- 1200 cyc/h 55 °C
- Tightening Torque
- control circuit 1.2 N.m || power circuit 18 N.m
- Hold-In Power Consumption In Va
- 8.9-10.9 VA, 40...400 Hz 0.9 20 °C)
- Motor Power Kw
- 90 kW at 380...400 V AC 50/60 Hz (AC-3) || 100 kW at 415 V AC 50/60 Hz (AC-3) || 100 kW at 440 V AC 50/60 Hz (AC-3) || 110 kW at 500 V AC 50/60 Hz (AC-3) || 110 kW at 660...690 V AC 50/60 Hz (AC-3) || 55 kW at 220...230 V AC 50/60 Hz (AC-3) || 33 kW at 400 V AC 50/60 Hz (AC-4)
- [Icw] Rated Short-Time Withstand Current
- 1500 A 40 °C - 10 s || 920 A 40 °C - 30 s || 740 A 40 °C - 1 min || 500 A 40 °C - 3 min || 400 A 40 °C - 10 min
Power Dissipation Per Pole12 W AC-3 || 25 W AC-1
[Ith] Conventional Free Air Thermal Current275 A (at 40 °C)
StandardsIEC 60947-4-1 || JIS C8201-4-1 || EN 60947-4-1 || IEC 60947-1 || EN 60947-1
Control Circuit TypeAC 40...400 Hz
Rated Breaking Capacity1480 A conforming to IEC 60947-4-1
Associated Fuse Rating200 A aM at <= 440 V || 315 A gG at <= 440 V
Inrush Power In Va950-1180 VA, 40...400 Hz 0.9 20 °C)
Pole Contact Composition3 NO
Operating Time35 ms closing at Uc) || 130 ms opening at Uc)
Mechanical Durability10 Mcycles
Compatibility CodeLC1F
Overvoltage CategoryIII
[Ui] Rated Insulation Voltage1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
Heat Dissipation8-9.8 W
Environment
- Ambient Air Temperature For Operation
- -5-55 °C
- Net Weight
- 4.65 kg
- Protective Treatment
- TH
- Operating Altitude
- 9842.52 ft (3000 m) without derating
- Depth
- 181 mm
Height174 mm
Ambient Air Temperature For Storage-60-80 °C
Ip Degree Of ProtectionIP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Width168.5 mm
Permissible Ambient Air Temperature Around The Device-40-70 °C
Specifications
- [Uc] Control Circuit Voltage
- 600 V AC 40...400 Hz
- [Ue] Rated Operational Voltage
- <= 460 V DC || <= 690 V AC 50/60 Hz
- Product Or Component Type
- contactor
- Utilisation Category
- AC-3 || AC-4 || AC-1
- Poles Description
- 3P
Range Of ProductTeSys F
Contactor Applicationmotor control || resistive load
RangeTeSys
[Ie] Rated Operational Current275 A (at <40 °C) at <= 440 V AC-1 || 185 A (at <55 °C) at <= 440 V AC-3
Device Short NameLC1F
Offer Sustainability
- Rohs Exemption Information
- Yes
- Environmental Disclosure
- ENVPEP080208EN
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile
- ENVEOLI100418
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Eu Rohs DirectiveCompliant with Exemptions
Downloads
Similar Products
CAD$2071.02/ EA
Loading add to cart quantity...