Schneider Electric LC1D115G7 TeSys Deca Contactor, 3P, 115A, 120V AC Coil, 120 mm Width
- MPN: LC1D115G7
- PPN: SCH-LC1D115G7
CAD
$1054.02
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Features
- Rated for 115A (AC-3) and up to 200A (AC-1), the LC1D115G7 is engineered for high-cycle motor control in demanding industrial environments. This high amperage capacity ensures reliable switching for motors up to 60 hp at 480V, preventing contact welding and extending the operational life of your automated systems.
- Featuring a "G7" voltage code, this contactor operates on a universal 120V AC control signal, making it a drop-in replacement for most industrial control panels and PLC outputs. This eliminates the need for additional control transformers or complex rewiring, simplifying your maintenance routine and reducing inventory overhead.
- The LC1D115G7 comes standard with 1 NO (Normally Open) and 1 NC (Normally Closed) built-in auxiliary contacts. These integrated contacts allow for immediate "seal-in" circuits or status feedback to your controller without the added cost and footprint of snap-on modules, though it remains fully expandable for more complex logic.
- This contactor is fully UL Listed, CSA Certified, and carries the CE mark, ensuring it meets the rigorous safety and performance standards required for international export and local inspections. You can specify this part with confidence for global applications, knowing it will pass strict regulatory audits and provide consistent arc suppression.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, Czechia, France, United States |
|---|
| Depth | 136 mm |
|---|
Complementary Attributes
| Control Circuit Type | AC 50/60 Hz |
|---|---|
| Irms Rated Making Capacity | 1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Maximum Operating Rate | 2400 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Control Circuit Voltage Limits | 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz1...1.15 Uc (55-70 °C):operational AC 50/60 Hz |
|---|---|
| Maximum Horse Power Rating | 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors40 hp at 230/240 V AC 50/60 Hz for 3 phase motors75 hp at 460/480 V AC 50/60 Hz for 3 phase motors100 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
Important Information Attributes
| Persona Type Ids | EU, OM, OM8, PB |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Contactor Application | resistive load, motor control |
| Inrush Power In Va | 280-350 VA 60 Hz cos phi 0.8 (at 20 °C), 280-350 VA 50 Hz cos phi 0.8 (at 20 °C) |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 6 Gn for 11 ms) |
| Mounting Support | rail, plate |
| Tightening Torque | control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2 |
| Certificate Agency | UL, CSA, CCC, UKCA, CE, EAC, Marine |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1 |
| Hold-in Power Consumption In Va | 2-18 VA 60 Hz cos phi 0.3 (at 20 °C), 2-18 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Carbon Footprint Of The Distribution Phase [A4] | 0.7508929239734572, 0.8 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0.3 kg CO2 eq., 0.2654427709841767 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 82 kg CO2 eq., 81.50132194244603 |
| Local Publishable Date | 2026-07-07 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant By Exemption |
| Rohs Eur Full Compliance Status | Compliant By Exemption |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Associated Fuse Rating | 250 A gG at <= 690 V coordination type 1 for power circuit200 A gG at <= 690 V coordination type 2 for power circuit10 A gG for signalling circuit |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Contact Compatibility | M13 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Heat Dissipation | 3-8 W at 50/60 Hz |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v5.9.4 |
| Total Lifecycle Carbon Footprint | 109 kg CO2 eq. |
| Control Circuit Voltage 18 Control Circuit Voltage | 120 V |
| Database Version | 2022-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3NO, a control circuit voltage 230V AC, a power circuit voltage 1000V and a rated operational current 150 A. |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 1219.83 |
| Energy Model - Installation [A5] | Electricity Mix; Production mix; Low voltage; FR |
| Energy Model - End Of Life [C1-c4] | Electricity Mix; Production mix; Low voltage; FR |
| Height Nominal | 158 mm |
| [Icw] Rated Short-time Withstand Current | 250 A 40 °C - 10 min for power circuit550 A 40 °C - 1 min for power circuit950 A 40 °C - 10 s for power circuit1100 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Uc] Control Circuit Voltage | 120 V AC 50/60 Hz |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
| Package Weight(Lbs) | 2.500 kg |
| Warranty (In Months) | 18 |
| Persona Type Names | End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Electrical Durability | 0.8 Mcycles 200 A AC-1 <= 440 V, 0.95 Mcycles 115 A AC-3 <= 440 V, 0.95 Mcycles 115 A AC-3e <= 440 V |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 55 kW at 380/400 V AC 50/60 Hz (AC-3e), 59 kW at 415/440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 660/690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e), 30 kW at 220/230 V AC 50/60 Hz (AC-3)55 kW at 380/400 V AC 50/60 Hz (AC-3)59 kW at 415/440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660/690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 220/230 V AC 50/60 Hz (AC-3e), 18.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 24 W AC-17.9 W AC-3, 7.9 W AC-3e |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| [Ie] Rated Operational Current | 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Connections - Terminals | control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable endpower circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable endpower circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable endpower circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable endpower circuit: connector 1 10-120 mm² - cable stiffness: solid without cable endpower circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 4.425806016866926, 4 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 22 kg CO2 eq., 22.22881266064238 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI100405EN |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 1904 |
| China Rohs In Scope | No |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Durability | 8 Mcycles |
| Operating Time | 6...20 ms opening20...50 ms closing |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range | TeSys |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Pep Code | ENVPEP0603001EN |
| Pep Verification Date | 2025-08-05 |
| Psr Version | PSR-0005-ed2-2016 03 29 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Production mix; Low voltage; CN |
| Energy Model - Use [B6] | Electricity Mix; Production mix; Low voltage; FR |
| Recyclability Potential In % | 54 |
| Width Nominal | 120 mm |
| [Ith] Conventional Free Air Thermal Current | 200 A (at 60 °C) for power circuit |
| [Ue] Rated Operational Voltage | power circuit <= 1000 V AC 25...400 Hzpower circuit <= 300 V DC |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536490065 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information. |
|---|---|
| Take Back | No |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI100405EN |
| Eu Rohs Directive | Compliant By Exemption |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Verification Date | 2025-08-05 |
| Psr Version | PSR-0005-ed2-2016 03 29 |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Recycled Metal Content At Cr Level | 0 % |
| Carbon Footprint | 109.17227631491296 |
| Environmental Disclosure | ENVPEP0603001EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Pep Code | ENVPEP0603001EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|


Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$1054.02
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$1054.02/ EA
Loading add to cart quantity...