TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V DC control circuit with no inrush consumption, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, China, France, Indonesia, Mexico, United States
Depth57 mm

Complementary Attributes

Control Circuit Type
DC standard
Irms Rated Making Capacity
110 A IEC 60947
Minimum Switching Current
5 mA
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at <50 °C)drop-out: 0.1...0.75 Uc (at <50 °C)
Maximum Operating Rate10000 cyc/h
Minimum Switching Voltage17 V

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG conforming to IEC 60947, 10 A gG conforming to VDE 0660
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, shocks contactor open10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
Utilisation Category
AC-15, DC-13
[Ue] Rated Operational Voltage
<= 690 V <= 400 Hz, <= 690 V <= 400 Hz<= 690 V <= 400 Hz, <= 690 V <= 400 Hz
Connections - Terminals
screw clamp terminals 2 0.34-1.5 mm²flexible without cable end, screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 2 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible with cable end, screw clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-1.5 mm²flexible with cable end
Carbon Footprint Of The End-of-life Phase [C1 To C4]
0.3180571443438615, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
1 kg CO2 eq., 1.1348165272383228
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Serviceability
No
Service Catalog Item
Finished good
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Free of Substances of Very High Concern above the threshold
Reach Compliance Directive
Free of Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant
Rohs Eur Full Compliance Status
Compliant
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Compatibility Code
CA3K
Device Short Name
CA3K
Immunity To Microbreaks
2 ms
Insulation Resistance
> 10 MOhm> 10 MOhm
Non Overlap Distance
0.5 mm
Pole Contact Composition
2 NO + 2 NC
Product Name
TeSys CAK
Protective Treatment
TC IEC 60068
Range Of Product
TeSys K control relay
Software Version
v6.2.4
Tightening Torque
1.3 N.m screw clamp terminals flat Ø 6 mm1.3 N.m screw clamp terminals Philips No 2 6 mm
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage 21
24 V
Connections Terminals 55 Connections Terminals
screw clamp terminals
Database Version
2024-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unit
unit
Energy Consumption On Product Lifetime In Kwh
140.16
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
58 mm
[Ith] Conventional Free Air Thermal Current
10 A (at 50 °C)
Hold-in Power Consumption In W
3-3 W 20 °C
Package Weight(Lbs)
221.000 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Flame RetardanceV1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mounting Supportrail, plate
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
[Ui] Rated Insulation Voltage690 V IEC 60947750 V VDE 0110 group C, 690 V BS 5424600 V CSA C22.2 No 14
Carbon Footprint Of The Distribution Phase [A4]0.4379807907104773, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.030109360466276436
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]57 kg CO2 eq., 56.65241524409139
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503003
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2448
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Contactor Applicationcontrol circuit
Heat Dissipation3-3 W
Inrush Power In W3-3 W 20 °C)
Mechanical Durability20 Mcycles
Operating Time10 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing15 ms coil de-energisation and NC closing25...35 ms coil energisation and NC opening
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typecontrol relay
RangeTeSys
ReturnabilityYes
Sustainable PackagingYes
Total Lifecycle Carbon Footprint59 kg CO2 eq.
Pole Contact Comp2 NO + 2 NC
Control Circuit Voltage 21 Control Circuit Voltage24 V
Pep CodeENVPEP1503003EN
Pep Verification Date2026-03-23
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; Europe, EU-27
Recyclability Potential In %63
Width Nominal45 mm
[Uc] Control Circuit Voltage24 V DC
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536410050

Environment Attributes Main

Ambient Air Temperature For Operation
-25-50 °C, -25-50 °C
Take Back
No
Recycled Metal Content At Cr Level
0 %
Toxic Heavy Metal Free
Yes
Carbon Footprint
58.57337906685032
Environmental Disclosure
ENVPEP1503003EN
Ip Degree Of Protection
IP2X
Packaging Made With Recycled Cardboard
Yes
Reach Free Of Svhc
Yes
Pep Code
ENVPEP1503003EN
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Ambient Air Temperature For Storage-50-80 °C, -50-80 °C
Reach Free ShvcYes
China Rohs RegulationX
Mercury FreeYes
Circularity ProfileENVEOLI1503003
Eu Rohs DirectiveCompliant
Operating Altitude6561.68 ft (2000 m) without derating
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-23
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Type
control relay
Range Of ProductTeSys K control relay

ETIM

ETIM 8
EC000196
ETIM 9EC000196

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months