Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets
Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets
Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets
Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets
Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets
Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets
Tripp Lite

Tripp Lite IS300HGDV Medical-Grade Isolation Transformer 300W 115/230V with 4 C13 Outlets

  • MPN: IS300HGDV
  • UPC: 037332199980
  • PPN: TRP-IS300HGDV

CAD

$1516.31

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

Isolator Series Dual-Voltage 115/230V 300W 60601-1 Medical-Grade Isolation Transformer, C14 Inlet, 4 C13 Outlets, TAA

Features

  • (2) Fuse sets included for 115V and 230V operation
  • Input/output cable selector data sheet included
  • Owner's manual included

Documentation & Downloads

Specifications

Additional

Output (VA)
300 VA
Nominal Input Voltage
115/230 VAC (100-125VAC or 200-250VAC range selectable by fuse)
Input Current
3.15 A @ 115 V, 1.6 A @ 230 V
AC Suppression Joule Rating
240 J
Output Voltage Regulation (Line Mode)
5.2%
Operating Elevation
0-3000 m (0-10,000 ft)
Unit Weight
12.35 lbs (5.60 kg)
Cooling Method
Convection
Leakage Current
Max AC Leakage Current less than 50 A
Storage Temperature Range
-15 to 50 C (5 to 122 F)
Power Input Receptacle
IEC-320-C14
Certifications
ANSI/AAMI ES60601-1:2005+A2+A1, IEC60601-1 3rd Edition +A1, cAN/CSA-C22.2 NO. 60601-1:14, CE, NOM
Noise Suppression Rating
35-65 dB
Color
White
UPC Code
037332199980
Output (Watts)300 W
Nominal Input Frequency50/60 Hz
Maximum Surge Amps70 A
Output Nominal Voltage115V/230V selectable (step-up, step-down, or pass-through)
THDiLess than 1%
Unit Dimensions4.33 x 5.91 x 7.87 in
Material of ConstructionSheet Metal Cabinet
Transformer TypeMedical Grade, Low Impedance Toroid - Line Isolation (Pass Through, Step Up or Step Down)
Operating Temperature Range0 to 40 C (32 to 104 F)
Operating Humidity Range5% to 95% RH (non-condensing)
Output Receptacles4 x C13
IEEE587 Cat. A Ringwave Let-ThroughReduced to 0.5 V Common Mode
Over Current Protection2x 3.15 A @ 115 V and 2x 1.6 A @ 230 V fuses included
Operating Elevation0-3000 m (0-10,000 ft)
Warranty2-year limited warranty