QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R
Square D

Square D QO24L70RB QO Circuit Breaker Loadcentre 240V 70A 1 Phase 2 Spaces NEMA 3R

  • MPN: QO24L70RB
  • UPC: 785901785132
  • PPN: SCH-QO24L70RB

CAD

$308.57

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 1 phase load center has 2 spaces and 4 circuits. This system provides 70A fixed main lugs in a NEMA 3R enclosure. This product is UL rated.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Mexico

Complementary Attributes

Line Rated Current
70 A
Rated Current70 A

Important Information Attributes

Persona Type Ids
EU, LC, OM
Tightening Torque
main lugs 35 lb.in, 14 AWG...10 AWG, aluminium/coppermain lugs 45 lb.in, 3 AWG, aluminium/coppermain lugs 40 lb.in, 8 AWG...4 AWG, aluminium/copper, main lugs 35 lb.in, 12 AWG...10 AWG, aluminium/copper
Carbon Footprint Of The End-of-life Phase [C1 To C4]
0.1 kg CO2 eq., 0.14009
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
10 kg CO2 eq., 9.917
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Use Carbon Footprint
4.0395
Weee Product Category
5
Eoli Availability Display
No need of specific recycling operations
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
2532
China Rohs In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Market Segmentation
Residential
Awg Gauge
12 AWG...3 AWG aluminium14 AWG...4 AWG copper
Cover Type
surface cover
Electrical Connection
lugs
Energy Efficiency Optimized
False
Material
tin plated aluminium: busbar
Number Of Circuits
4
Number Of Tandem Circuit Breakers
2
Product Availability
Stock - Normally stocked in distribution facility
Range Of Product
QO
Software Version
EIME v5.9.4
Sustainable Packaging
No
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Database Version
2022-01
Pcr Version
PCR-ed3-EN-2015 04 02
Type Of Verification For The Pep
Independent external review
Functional-unit Description
Protect persons during 20 years against direct contact with live parts and allow grouping monitoring, control and protection devices in a single enclosure or a cabinet having the following dimensions 952.5mm x1219.2mm x 101.6mm, comply with UL 67 and CSA22.2 with an available offer:& 10-suitable for use on 120/240 Vac and 48 Vdc systems& 10-rated 30–125 A& 10-supplies from two to sixteen circuits& 10-surface or flush-mounted cover& 10-Types 1 & 3R& 10-main lugs only
Functional-unit Unit
unit
Energy Model - Manufacturing [A1-a3]
Energy model used: Tlaxcala Mexico
Energy Model - Use [B6]
Electricity mix; AC; consumption mix, at consumer; 120V; US
Recyclability Potential In %
90
Width Nominal
124 mm
[Ue] Rated Operational Voltage
120/240 V AC
Carbon Footprint (Kg Co2 Eq Total Life Cycle)
14.921
Package Weight(Lbs)
2.295 kg
Warranty (In Months)
18
Air Pollution (M3) Manufacturing [A1-a3]
2633.2
Air Pollution (M3) Installation [A5]
2.0981
Air Pollution (M3) End Of Life [C1-c4]
14.371
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3]
89.214
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6]
49.182
Global Warming (Kg.Equivalent.Co2) Total Life Cycle
14.921
Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6]
4.0395
Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3]
137.44
Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4]
1.5518
Materials For Recycling (Kg) End Of Life [C1-c4]
1.2552
Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3]
32.333
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3]
165.38
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6]
51.116
Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle
242.9
Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4]
10.947
Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4]
2.032
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3]
9.5022
Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
2.8125
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle
227.3
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4]
10.932
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4]
2.0297
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]
18.083
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]
-8.5808
Water Pollution (M3) Total Life Cycle
1264.8
Water Pollution (M3) Distribution [A4]
127.32
Water Pollution (M3) Operational Energy Use [B6]
199.15
Customs Code
8537109150
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer
Carbon Footprint Of The Distribution Phase [A4]0.77411, 0.8 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.050582, 0.1 kg CO2 eq.
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]4 kg CO2 eq., 4.0395
Local Publishable Date2026-07-14
Stocking FlagN
Manufacturing Carbon Footprint9.917
Weee ScopeIn
Scope PerimeterAt least in Europe
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticNo
Tier Id1
Function Option IdSTANDARD
Market Segmentation IdRESIDENTIAL
Product Kit IdentifierN
Box Number1R
Device Compositiongrounding bar (ordered separately)
Enclosure Materialwelded galvannealed steel
Load Center TypeFixed Mains (lugs)
Mounting Modevertical
Number Of Spaces2
Phase1 phase 3 wires
Product Or Component TypeLoad Center
ReturnabilityYes
Surface Finishbaked enamel Gray
Total Lifecycle Carbon Footprint15 kg CO2 eq.
Pep CodeENVPEP2212002EN
Pep Verification Date2023-08-01
Psr VersionPSR-0005-ed2-EN-2016 03 29
Data Sourcereferent product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Installation [A5]Electricity mix; AC; consumption mix, at consumer; 120V; US
Energy Model - End Of Life [C1-c4]Electricity mix; AC; consumption mix, at consumer; 120V; US
Height Nominal238 mm
Certificate AgencyUL Listed
Short-circuit Current65 kA
Nbr. Of Units In Pkg.1
Take-backNo
Air Pollution (M3) Total Life Cycle3024.9
Air Pollution (M3) Distribution [A4]32.193
Air Pollution (M3) Operational Energy Use [B6]343.04
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle151.56
Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4]10.877
Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4]1.6306
Global Warming (Kg.Equivalent.Co2) Manufacturing [A1-a3]9.917
Hazardous Waste Disposed Of (Kg) Total Life Cycle139.1
Hazardous Waste Disposed Of (Kg) Operational Energy Use [B6]0.108
Materials For Recycling (Kg) Total Life Cycle2.3991
Non-hazardous Waste Disposed Of (Kg) Total Life Cycle33.001
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle230.11
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Distribution [A4]10.932
Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4]2.0297
Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3]174.88
Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6]54.382
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle12.786
Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6]3.266
Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]2.8125
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3]162.57
Use Of Non-renewable Primary Energy Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6]51.116
Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle18.083
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle-5.2966
Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6]3.266
Water Pollution (M3) Manufacturing [A1-a3]915.15
Water Pollution (M3) Installation [A5]7.6335
Water Pollution (M3) End Of Life [C1-c4]15.568

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take Back
No
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Environmental Disclosure
ENVPEP2212002EN
Nema Degree Of Protection
NEMA 3R weatherproof enclosure
Packaging Without Single Use Plastic
No
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2023-08-01
Psr Version
PSR-0005-ed2-EN-2016 03 29
Ambient Air Temperature For Operation-5 °C, -5 °C, 40 °C
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint14.921
Eu Rohs DirectiveCompliant
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP2212002EN
Pcr VersionPCR-ed3-EN-2015 04 02
Type Of Verification For The PepIndependent external review

General Attributes

Phase
1 phase 3 wires
Range Of Product
QO
Product Or Component TypeLoad Center

ETIM

ETIM 8
EC000214
ETIM 9EC000214

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months