TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20
TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20
Schneider Electric

Schneider Electric LC1D115B7 TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20

  • MPN: LC1D115B7
  • PPN: SCH-LC1D115B7
  • If you can't find the product or are unsure which one you need, please use the Product Selector tool below
  • CAD

    $1054.02

    / EA

    Available to Order

    Lead times may vary. For an accurate estimate please contact us.

    Available To Ship Immediately:0

    Loading dialog...

    Looking to buy a large quantity?

    To View Branch Inventory And Your Custom Pricing

    Spec sheet

    Description

    TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 115A/1000V AC-3 (55kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V 50/60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirrror certified), power connection by screw connectors 2 inputs, control connection by screw clamp terminals. For operating rates until 2400 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with up to a 600VAC 250A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

    Documentation & Downloads

    Specifications

    Key Specifications

    Country of Origin
    Czechia, France, United States
    Depth136 mm

    Complementary Attributes

    Control Circuit Type
    AC 50/60 Hz standard
    Irms Rated Making Capacity
    1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
    Maximum Operating Rate
    2400 cyc/h at 60 °C
    Minimum Switching Voltage
    17 V for signalling circuit
    Control Circuit Voltage Limits0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
    Maximum Horse Power Rating30 hp at 200/208 V AC 50/60 Hz for 3 phase motors40 hp at 230/240 V AC 50/60 Hz for 3 phase motors75 hp at 460/480 V AC 50/60 Hz for 3 phase motors100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    Minimum Switching Current5 mA for signalling circuit
    Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947

    Important Information Attributes

    Persona Type Ids
    EU, OM, OM8, PB
    Market Segmentation Id
    COMMERCIAL, INDUSTRIAL
    Contactor Application
    motor control, resistive load
    Inrush Power In Va
    280-350 VA 60 Hz cos phi 0.8 (at 20 °C), 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
    Mechanical Robustness
    vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 6 Gn for 11 ms)
    Mounting Support
    rail, plate
    Tightening Torque
    control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
    Certificate Agency
    UL, CSA, CCC, UKCA, CE, EAC, Marine
    [Ui] Rated Insulation Voltage
    signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    Hold-in Power Consumption In Va
    2-18 VA 60 Hz cos phi 0.3 (at 20 °C), 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
    Carbon Footprint Of The Distribution Phase [A4]
    0.7508929239734572, 0.8 kg CO2 eq.
    Carbon Footprint Of The Installation Phase [A5]
    0.3 kg CO2 eq., 0.2654427709841767
    Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
    82 kg CO2 eq., 81.50132194244603
    Local Publishable Date
    2026-07-07
    Stocking Flag
    Y
    Device Type
    LV equipment - LV contactor
    Traceability
    No
    Average Life Duration
    20 year(s)
    Weee Scope
    In
    Scope Perimeter
    At least in Europe
    End Of Life Doc Ref
    ENVEOLI100405EN
    Reach Full Compliance Status Id
    CONTAINS_SVHC
    Rohs Eur In Scope
    Yes
    Rohs Eur Conformity Date
    1904
    China Rohs In Scope
    No
    Without Single Use Plastic
    Yes
    Tier Id
    1
    Function Option Id
    STANDARD
    Product Kit Identifier
    N
    Average Impedance
    0.6 mOhm - Ith 200 A 50 Hz for power circuit
    Compatibility Code
    LC1D
    Device Short Name
    LC1D
    Flame Retardance
    V1 conforming to UL 94
    Mechanical Durability
    8 Mcycles
    Operating Time
    6...20 ms opening20...50 ms closing
    Pole Contact Composition
    3 NO
    Product Or Component Type
    contactor
    Range
    TeSys
    Returnability
    Yes
    Signalling Circuit Frequency
    25...400 Hz
    Sustainable Packaging
    Yes
    Weee Label
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Pep Code
    ENVPEP0603001EN
    Pep Verification Date
    2025-08-05
    Psr Version
    PSR-0005-ed2-2016 03 29
    Data Source
    extrapolated product
    Functional-unit Quantity
    1
    Reference Lifetime In Y
    20
    Energy Model - Manufacturing [A1-a3]
    Electricity Mix; Production mix; Low voltage; CN
    Energy Model - Use [B6]
    Electricity Mix; Production mix; Low voltage; FR
    Recyclability Potential In %
    54
    Width Nominal
    120 mm
    [Ith] Conventional Free Air Thermal Current
    200 A (at 60 °C) for power circuit
    [Ue] Rated Operational Voltage
    power circuit <= 1000 V AC 25...400 Hzpower circuit <= 300 V DC
    Nbr. Of Units In Pkg.
    1
    Take-back
    No
    Customs Code
    8536490065
    Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    Market SegmentationCommercial, Industrial
    Electrical Durability0.8 Mcycles 200 A AC-1 <= 440 V, 0.95 Mcycles 115 A AC-3 <= 440 V, 0.95 Mcycles 115 A AC-3e <= 440 V
    Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    Motor Power Kw55 kW at 380/400 V AC 50/60 Hz (AC-3e), 59 kW at 415/440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 660/690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e), 30 kW at 220/230 V AC 50/60 Hz (AC-3)55 kW at 380/400 V AC 50/60 Hz (AC-3)59 kW at 415/440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660/690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 220/230 V AC 50/60 Hz (AC-3e), 18.5 kW at 400 V AC 50/60 Hz (AC-4)
    Power Dissipation Per Pole24 W AC-17.9 W AC-3, 7.9 W AC-3e
    Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
    [Ie] Rated Operational Current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    Connections - Terminalscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable endpower circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable endpower circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable endpower circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable endpower circuit: connector 1 10-120 mm² - cable stiffness: solid without cable endpower circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end
    Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    Carbon Footprint Of The End-of-life Phase [C1 To C4]4.425806016866926, 4 kg CO2 eq.
    Carbon Footprint Of The Manufacturing Phase [A1 To A3]22 kg CO2 eq., 22.22881266064238
    Local Data StatusPublishable
    Return IndicatorY
    Stock Policy1
    ServiceabilityNo
    Field Service DivisionPPIBS
    Service Catalog ItemFinished good
    Weee Product Category5
    Eoli Availability DisplayYes
    Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
    Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
    Rohs Eur StatusCompliant By Exemption
    Rohs Eur Full Compliance StatusCompliant By Exemption
    With Recycled CardboardYes
    Product Contributes To Saved And Avoided EmissionsNo
    Tier1
    Function OptionStandard
    Associated Fuse Rating250 A gG at <= 690 V coordination type 1 for power circuit200 A gG at <= 690 V coordination type 2 for power circuit10 A gG for signalling circuit
    Coil Technologybuilt-in bidirectional peak limiting diode suppressor
    Contact CompatibilityM13
    Fire Resistance850 °C IEC 60695-2-1
    Heat Dissipation3-8 W at 50/60 Hz
    Number Of Poles3P
    Overvoltage CategoryIII
    Product AvailabilityStock - Normally stocked in distribution facility
    Protective TreatmentTHIEC 60068-2-30
    Range Of ProductTeSys Deca
    Safety Reliability LevelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
    Software Versionv5.9.4
    Total Lifecycle Carbon Footprint109 kg CO2 eq.
    Control Circuit Voltage 18 Control Circuit Voltage24 V
    Database Version2022-01
    Pcr VersionPEP-PCR-ed4-2021 09 06
    Type Of Verification For The PepIndependent internal review
    Functional-unit DescriptionSwitch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3NO, a control circuit voltage 230V AC, a power circuit voltage 1000V and a rated operational current 150 A.
    Functional-unit Unitunit
    Energy Consumption On Product Lifetime In Kwh1219.83
    Energy Model - Installation [A5]Electricity Mix; Production mix; Low voltage; FR
    Energy Model - End Of Life [C1-c4]Electricity Mix; Production mix; Low voltage; FR
    Height Nominal158 mm
    [Icw] Rated Short-time Withstand Current250 A 40 °C - 10 min for power circuit550 A 40 °C - 1 min for power circuit950 A 40 °C - 10 s for power circuit1100 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
    [Uc] Control Circuit Voltage24 V AC 50/60 Hz
    [Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
    Package Weight(Lbs)2.480 kg
    Warranty (In Months)18

    Environment Attributes Main

    China Rohs Regulation
    Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    Take Back
    No
    Mercury Free
    Yes
    Circularity Profile
    ENVEOLI100405EN
    Eu Rohs Directive
    Compliant By Exemption
    Operating Altitude
    0...9842.52 ft (0...3000 m)
    Packaging Without Single Use Plastic
    Yes
    Reach Regulation
    Reference contains Substances of Very High Concern above the threshold
    Pep Verification Date
    2025-08-05
    Psr Version
    PSR-0005-ed2-2016 03 29
    Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    Recycled Metal Content At Cr Level0 %
    Carbon Footprint109.17227631491296
    Environmental DisclosureENVPEP0603001EN
    Ip Degree Of ProtectionIP20 front face IEC 60529
    Packaging Made With Recycled CardboardYes
    Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
    Pep CodeENVPEP0603001EN
    Pcr VersionPEP-PCR-ed4-2021 09 06
    Type Of Verification For The PepIndependent internal review

    General Attributes

    Product Or Component Type
    contactor
    Range Of ProductTeSys Deca

    ETIM

    ETIM 8
    EC000066
    ETIM 9EC000066

    Contractual Warranty Attributes

    Warranty Period
    18 months
    Warranty18 months

    Accessories

    Loading carousel layout...

    Similar Products

    Loading carousel layout...

    CAD$1054.02/ EA

    Loading add to cart quantity...

    banner

    Need assistance?

    We can help! Connect with our Sales Team Today!