TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20
TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20
Schneider Electric

Schneider Electric LC1D115B7 TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20

  • MPN: LC1D115B7
  • PPN: SCH-LC1D115B7
  • If you can't find the product or are unsure which one you need, please use the Product Selector tool below
  • CAD

    $1054.02

    / EA

    Available to Order

    Lead times may vary. For an accurate estimate please contact us.

    Company Stock:

    0

    Loading dialog...

    Looking to buy a large quantity?

    To view product inventory

    Spec sheet

    Description

    TeSys Deca Contactor 3P, 115A, 24V AC, 2400 Cycles/Hour, IP20

    Documentation & Downloads

    Specifications

    Key Specifications

    Country of Origin
    Czechia, France, United States
    Depth136 mm

    Complementary Attributes

    Control Circuit Voltage Limits
    0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz, 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
    Maximum Horse Power Rating
    30 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    Maximum Operating Rate
    2400 cyc/h at 60 °C
    Minimum Switching Voltage
    17 V for signalling circuit
    Irms Rated Making Capacity1260 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    Control Circuit TypeAC 50/60 Hz standard
    Minimum Switching Current5 mA for signalling circuit
    Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947

    Important Information Attributes

    Persona Type Ids
    EU, OM, OM8, PB
    Market Segmentation Id
    COMMERCIAL, INDUSTRIAL
    Associated Fuse Rating
    250 A gG at <= 690 V coordination type 1 for power circuit, 200 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit
    Electrical Durability
    0.8 Mcycles 200 A AC-1 <= 440 V, 0.95 Mcycles 115 A AC-3 <= 440 V, 0.95 Mcycles 115 A AC-3e <= 440 V
    Insulation Resistance
    > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    Motor Power Kw
    55 kW at 380/400 V AC 50/60 Hz (AC-3e), 59 kW at 415/440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 660/690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e)30 kW at 220/230 V AC 50/60 Hz (AC-3), 55 kW at 380/400 V AC 50/60 Hz (AC-3), 59 kW at 415/440 V AC 50/60 Hz (AC-3), 75 kW at 500 V AC 50/60 Hz (AC-3), 80 kW at 660/690 V AC 50/60 Hz (AC-3), 65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 220/230 V AC 50/60 Hz (AC-3e), 18.5 kW at 400 V AC 50/60 Hz (AC-4)
    Operating Time
    6...20 ms opening, 20...50 ms closing
    Safety Reliability Level
    B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
    Utilisation Category
    AC-3, AC-3e, AC-1, AC-4
    [Icw] Rated Short-time Withstand Current
    250 A 40 °C - 10 min for power circuit, 550 A 40 °C - 1 min for power circuit, 950 A 40 °C - 10 s for power circuit, 1100 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    [Ue] Rated Operational Voltage
    power circuit <= 1000 V AC 25...400 Hz, power circuit <= 300 V DC
    Connections - Terminals
    control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end
    Non-overlap Time
    1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    Carbon Footprint Of The End-of-life Phase [C1 To C4]
    4.425806016866926, 4 kg CO2 eq.
    Carbon Footprint Of The Manufacturing Phase [A1 To A3]
    22 kg CO2 eq., 22.22881266064238
    Local Data Status
    Publishable
    Return Indicator
    Y
    Stock Policy
    2
    Serviceability
    No
    Field Service Division
    PPIBS
    Service Catalog Item
    Finished good
    Weee Product Category
    5
    Eoli Availability Display
    Yes
    Reach Full Compliance Status
    Reference contains Substances of Very High Concern above the threshold
    Reach Compliance Directive
    Reference contains Substances of Very High Concern above the threshold
    Rohs Eur Status
    Compliant By Exemption
    Rohs Eur Full Compliance Status
    Compliant By Exemption
    With Recycled Cardboard
    Yes
    Product Contributes To Saved And Avoided Emissions
    No
    Tier
    1
    Function Option
    Standard
    Average Impedance
    0.6 mOhm - Ith 200 A 50 Hz for power circuit
    Compatibility Code
    LC1D
    Device Short Name
    LC1D
    Flame Retardance
    V1 conforming to UL 94
    Mechanical Durability
    8 Mcycles
    Overvoltage Category
    III
    Product Availability
    Stock - Normally stocked in distribution facility
    Protective Treatment
    THIEC 60068-2-30
    Range Of Product
    TeSys Deca
    Signalling Circuit Frequency
    25...400 Hz
    Sustainable Packaging
    Yes
    Weee Label
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Pep Code
    ENVPEP0603001EN
    Pep Verification Date
    2025-08-05
    Psr Version
    PSR-0005-ed2-2016 03 29
    Data Source
    extrapolated product
    Functional-unit Quantity
    1
    Reference Lifetime, In Y
    20
    Energy Model - Manufacturing [A1-a3]
    Electricity Mix; Production mix; Low voltage; CN
    Energy Model - Use [B6]
    Electricity Mix; Production mix; Low voltage; FR
    Recyclability Potential, In %
    54
    Width Nominal
    120 mm
    [Uc] Control Circuit Voltage
    24 V AC 50/60 Hz
    Nbr. Of Units In Pkg.
    1
    Take-back
    No
    Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    Market SegmentationCommercial, Industrial
    Contactor Applicationmotor control, resistive load
    Inrush Power In Va280-350 VA 60 Hz cos phi 0.8 (at 20 °C), 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
    Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 6 Gn for 11 ms)
    Mounting Supportrail, plate
    Power Dissipation Per Pole24 W AC-1, 7.9 W AC-3, 7.9 W AC-3e
    Tightening Torquecontrol circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
    Certificate AgencyUL, CSA, CCC, UKCA, CE, EAC, Marine
    [Ie] Rated Operational Current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    [Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V UL, power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    Hold-in Power Consumption In Va2-18 VA 60 Hz cos phi 0.3 (at 20 °C), 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
    Carbon Footprint Of The Distribution Phase [A4]0.7508929239734572, 0.8 kg CO2 eq.
    Carbon Footprint Of The Installation Phase [A5]0.3 kg CO2 eq., 0.2654427709841767
    Carbon Footprint Of The Use Phase [B2, B3, B4, B6]82 kg CO2 eq., 81.50132194244603
    Local Publishable Date2026-03-11
    Stocking FlagN
    Device TypeLV equipment - LV contactor
    TraceabilityNo
    Average Life Duration20 year(s)
    Weee ScopeIn
    Scope PerimeterAt least in Europe
    End Of Life Doc RefENVEOLI100405EN
    Reach Full Compliance Status IdCONTAINS_SVHC
    Rohs Eur In ScopeYes
    Rohs Eur Conformity Date1904
    China Rohs In ScopeNo
    Without Single Use PlasticYes
    Tier Id1
    Function Option IdSTANDARD
    Product Kit IdentifierN
    Coil Technologybuilt-in bidirectional peak limiting diode suppressor
    Contact CompatibilityM13
    Fire Resistance850 °C IEC 60695-2-1
    Heat Dissipation3-8 W at 50/60 Hz
    Number Of Poles3P
    Pole Contact Composition3 NO
    Product Or Component Typecontactor
    RangeTeSys
    ReturnabilityYes
    Software Versionv5.9.4
    Total Lifecycle Carbon Footprint109 kg CO2 eq.
    Control Circuit Voltage 18 Control Circuit Voltage24 V
    Database Version2022-01
    Pcr VersionPEP-PCR-ed4-2021 09 06
    Type Of Verification For The PepIndependent internal review
    Functional-unit DescriptionSwitch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3NO, a control circuit voltage 230V AC, a power circuit voltage 1000V and a rated operational current 150 A.
    Functional-unit Unitunit
    Energy Consumption On Product Lifetime, In Kwh1219.83
    Energy Model - Installation [A5]Electricity Mix; Production mix; Low voltage; FR
    Energy Model - End Of Life [C1-c4]Electricity Mix; Production mix; Low voltage; FR
    Height Nominal158 mm
    [Ith] Conventional Free Air Thermal Current200 A (at 60 °C) for power circuit
    [Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
    Package Weight(Lbs)2.480 kg
    Warranty (In Months)18

    Environment Attributes Main

    China Rohs Regulation
    Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    Permissible Ambient Air Temperature Around The Device
    -40-60 °C-40-60 °C, 60-70 °C with derating
    Recycled Metal Content At Cr Level
    0 %
    Carbon Footprint
    109.17227631491296
    Environmental Disclosure
    ENVPEP0603001EN
    Ip Degree Of Protection
    IP20 front face IEC 60529
    Packaging Made With Recycled Cardboard
    Yes
    Reach Regulation
    Reference contains Substances of Very High Concern above the threshold
    Pep Verification Date
    2025-08-05
    Psr Version
    PSR-0005-ed2-2016 03 29
    Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    Take BackNo
    Mercury FreeYes
    Circularity ProfileENVEOLI100405EN
    Eu Rohs DirectiveCompliant By Exemption
    Operating Altitude0...9842.52 ft (0...3000 m)
    Packaging Without Single Use PlasticYes
    Pep CodeENVPEP0603001EN
    Pcr VersionPEP-PCR-ed4-2021 09 06
    Type Of Verification For The PepIndependent internal review

    General Attributes

    Product Or Component Type
    contactor
    Range Of ProductTeSys Deca

    ETIM

    ETIM 8
    EC000066
    ETIM 9EC000066

    Contractual Warranty Attributes

    Warranty Period
    18 months
    Warranty18 months

    Accessories

    Loading carousel layout...

    Similar Products

    Loading carousel layout...

    CAD$1054.02/ EA

    Loading add to cart quantity...

    banner

    Need assistance?

    We can help! Connect with our Sales Team Today!

    ",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])