Documentation & Downloads

Schneider Electric LC1D32E7 TeSys Deca Contactor 3P 32A 48V AC Coil, DIN-Rail Mounting
- MPN: LC1D32E7
- PPN: SCH-LC1D32E7
CAD
$337.14
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France, Indonesia, India, Singapore
Complementary Attributes
- Control Circuit Voltage Limits
- 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
- Maximum Horse Power Rating
- 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Maximum Motor Phase Current
- 32 A
- Minimum Switching Current
- 5 mA for signalling circuit
- Rated Breaking Capacity
- 550 A at 440 V for power circuit conforming to IEC 60947
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
- Electrical Durability
- 1.65 Mcycles 32 A AC-3 <= 440 V, 1.4 Mcycles 50 A AC-1 <= 440 V, 1.65 Mcycles 32 A AC-3e <= 440 V
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Motor Power Kw
- 15 kW at 380...400 V AC 50/60 Hz (AC-3e), 15 kW at 415...440 V AC 50/60 Hz (AC-3e), 18.5 kW at 500 V AC 50/60 Hz (AC-3e), 18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)7.5 kW at 220...230 V AC 50/60 Hz (AC-3), 15 kW at 380...400 V AC 50/60 Hz (AC-3), 15 kW at 415...440 V AC 50/60 Hz (AC-3), 18.5 kW at 500 V AC 50/60 Hz (AC-3), 18.5 kW at 660...690 V AC 50/60 Hz (AC-3), 7.5 kW at 400 V AC 50/60 Hz (AC-4), 7.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
- Operating Time
- 12...22 ms closing, 4...19 ms opening
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Utilisation Category
- AC-4, AC-1, AC-3, AC-3e
- [Icw] Rated Short-time Withstand Current
- 260 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 60 A 40 °C - 10 min for power circuit, 138 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
- [Ith] Conventional Free Air Thermal Current
- 10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
- [Ue] Rated Operational Voltage
- power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
- Connections - Terminals
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end, screw clamp terminals, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
- Non-overlap Time
- 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
- Carbon Footprint Of The End-of-life Phase [C1 To C4]
- 0.9107704459160854, 0.9 kg CO2 eq.
- Carbon Footprint Of The Use Phase [B2, B3, B4, B6]
- 144 kg CO2 eq., 143.61734093142167
- Local Publishable Date
- 2026-03-27
- Stocking Flag
- N
- Device Type
- LV equipment - LV contactor
- Traceability
- No
- Average Life Duration
- 20 year(s)
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Free of Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Free of Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant
- Rohs Eur Full Compliance Status
- Compliant
- China Rohs Label
- 1
- Without Single Use Plastic
- Yes
- Tier Id
- 1
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Coil Technology
- without built-in suppressor module
- Contact Compatibility
- M2
- Fire Resistance
- 850 °C IEC 60695-2-1
- Heat Dissipation
- 2-3 W at 50/60 Hz
- Number Of Poles
- 3P
- Pole Contact Composition
- 3 NO
- Product Or Component Type
- contactor
- Range Of Product
- TeSys Deca
- Signalling Circuit Frequency
- 25...400 Hz
- Sustainable Packaging
- Yes
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Inf Motor Phase Current
- 32 A
- Database Version
- 2023-02
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime, In Kwh
- 350.4
- Energy Model - Installation [A5]
- Electricity Mix; Low voltage; 2018; Europe, EU-27
- Energy Model - End Of Life [C1-c4]
- Electricity Mix; Low voltage; 2018; Europe, EU-27
- Height Nominal
- 85 mm
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947
- Package Weight(Lbs)
- 408.000 g
- Warranty (In Months)
- 18
Environment Attributes Main
- China Rohs Regulation
- Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
- Permissible Ambient Air Temperature Around The Device
- -40-60 °C-40-60 °C, 60-70 °C with derating
- Reach Free Shvc
- Yes
- Carbon Footprint
- 147.00733095178674
- Environmental Disclosure
- ENVPEP1102029EN
- Ip Degree Of Protection
- IP20 front face IEC 60529
- Packaging Made With Recycled Cardboard
- Yes
- Reach Free Of Svhc
- Yes
- Pep Code
- ENVPEP1102029EN
- Pcr Version
- PCR-4-ed4-EN-2021 09 06
- Type Of Verification For The Pep
- Independent external review
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$337.14
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$337.14/ EA
Loading add to cart quantity...