Schneider Electric LC1D65AF7 TeSys Deca Contactor, 3P 65A 110V AC, Compact Design, 55mm Width
- MPN: LC1D65AF7
- PPN: SCH-LC1D65AF7
- UNSPSC: 39121529
CAD
$506.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Features
- Equipped with an optimized 110V AC coil that functions seamlessly across both 50Hz and 60Hz frequencies, this device eliminates coil-buzzing and chatter caused by grid fluctuations. The wide voltage tolerance prevents dropouts during momentary voltage sags, making it an ideal choice for panel builders creating machinery bound for global export.
- Rated for 65 Amps under AC-3 utilization categories, this heavy-duty contactor is built to manage the intense inrush currents of three-phase induction motors. Its premium silver-nickel alloy contacts minimize electrical arcing and heat generation, ensuring long-lasting, reliable motor control for high-demand applications like industrial pumps, fans, and heavy conveyors.
- Featuring factory-installed, mirror-linked auxiliary contacts, the LC1D65AF7 allows for instant integration of safety interlocking, status signaling, or PLC feedback loops without the added cost of external add-on blocks. The mechanically linked design guarantees that the NC contact will never be closed at the same time as the NO main power poles, complying with strict global safety standards.
- Utilizing Schneider s patented EverLink power terminal block technology, this contactor maintains constant pressure on the connected wires even as the copper cold-flows over time. This unique spring-loaded design ensures a gas-tight, vibration-resistant connection that eliminates the need for periodic torque retightening, drastically reducing the risk of localized hotspots and terminal meltdowns.
- As a core module of the renowned TeSys Deca family, this contactor features a modular footprint that allows for direct, tool-free plug-in assembly of LRD365 thermal overload relays or electronic protection modules. This plug-and-play architecture slashes panel assembly time, minimizes enclosure space requirements, and simplifies field upgrades for maintenance electricians.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Indonesia, United States |
|---|---|
| Depth | 120 mm |
| Weight | 860 g |
|---|
Complementary Attributes
| Control Circuit Type | AC 50/60 Hz standard, AC 50/60 Hz standard |
|---|---|
| Maximum Horse Power Rating | 20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 1 phase motors20 hp at 200/208 V AC 50/60 Hz for 3 phase motors50 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Uc Control Circuit Voltage | 110 V, 110 V AC 50/60 Hz |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11000 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Icw Rated Short Time Withstand Current | 640 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| Uimp Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Control Circuit Voltage Limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
|---|---|
| Ie Rated Operational Current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Ui Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1 |
| Maximum Motor Phase Current | 65 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Ue Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit |
| Electrical Durability | 1.4 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 65 A AC-3 <= 440 V, 1.45 Mcycles 65 A AC-3e <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms) |
| Mounting Support | rail, plate |
| Range | TeSys, TeSys Deca |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Control Circuit Voltage | 110 V |
| Non Overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 1.2081206897335017, 1 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 4 kg CO2 eq., 4.251993973978119 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503009EN |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 1926 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Heat Dissipation | 4-5 W at 50/60 Hz |
| Mechanical Durability | 6 Mcycles |
| Operating Time | 4...19 ms opening12...26 ms closing |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Total Lifecycle Carbon Footprint | 83 kg CO2 eq. |
| Inf Motor Phase Current | 65 A |
| Data Source | extrapolated product |
| Width Nominal | 55 mm |
| Customs Code | 8536490065 |
| Hold In Power Consumption In Va | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)15-15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Functional Unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional Unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 851.91 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Contactor Application | resistive load, motor control |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 30 kW at 380/400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660/690 V AC 50/60 Hz (AC-3e), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3)30 kW at 380/400 V AC 50/60 Hz (AC-3)37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660/690 V AC 50/60 Hz (AC-3), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 9.6 W AC-16.3 W AC-3, 6.3 W AC-3e |
| Tightening Torque | control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2 |
| Connections Terminals | control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end, EverLink BTR screw connectors |
| Certificate Agency | CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC |
| Carbon Footprint Of The Distribution Phase A4 | 0.39860579699531423, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0.1 kg CO2 eq., 0.05192179391361554 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 77 kg CO2 eq., 76.62394170546868 |
| Local Publishable Date | 2026-06-27 |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | without built-in suppressor module |
| Contact Compatibility | M2 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Inrush Power In Va | 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)160-160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Database Version | 2024-01 |
| Height Nominal | 122 mm |
| Nbr. Of Units In Pkg. | 1 |
| Ith Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit |
| Warranty In Months | 18 |
| Functional Unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Recyclability Potential In % | 62 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Take Back | No |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 82.53458396008924 |
| Environmental Disclosure | ENVPEP1503009EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Pep Code | ENVPEP1503009EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503009EN |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|---|
| ETIM 10 | EC000066 |
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|


Accessories
Loading carousel layout...
Loading carousel layout...
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$506.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
CAD$506.98/ EA
Loading add to cart quantity...