LC1K0610M7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 220V 50/60Hz AC coil and 1NO auxiliary contact. LC1K0610M7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 220V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Features

  • TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options
  • The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications
  • One of the smallest contactor offerings in the market
  • The range delivers strong performance for its compact size and promises seamless integration in all applications.
  • Widely used for industry, infrastructure and building applications
  • Designed for simple control systems

Documentation & Downloads

Specifications

Key Specifications

Country of OriginIndonesia
Depth57 mm
Weight180 g

Complementary Attributes

Irms Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Icw Rated Short Time Withstand Current90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
Uc Control Circuit VoltageAC 50/60 Hz, 220...230 V
Ui Rated Insulation Voltagesignalling circuit 600 V UL 508signalling circuit 600 V CSA C22.2 No 14power circuit 600 V UL 508power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, power circuit 600 V CSA C22.2 No 14
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C)
Maximum Operating Rate3600 cyc/h
Minimum Switching Voltage17 V for signalling circuit
Rated Breaking Capacity110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Ie Rated Operational Current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Ue Rated Operational Voltagepower circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
Control Circuit TypeAC 50/60 Hz
Maximum Motor Phase Current6 A
Minimum Switching Current5 mA for signalling circuit
Uimp Rated Impulse Withstand Voltage8 kV

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Associated Fuse Rating25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Electrical Durability1.3 Mcycles 6 A AC-3 <= 440 V, 1.3 Mcycles 6 A AC-3e <= 440 V, 0.05 Mcycles 36 A AC-4 <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw2.2 kW 380...415 V AC 50/60 Hz AC-3e, 3 kW 440/690 V AC 50/60 Hz AC-3e2.2 kW 380...415 V AC 50/60 Hz AC-4, 3 kW 440/690 V AC 50/60 Hz AC-41.5 kW 220...230 V AC 50/60 Hz AC-32.2 kW 380...415 V AC 50/60 Hz AC-33 kW 440/690 V AC 50/60 Hz AC-3, 1.5 kW 220...230 V AC 50/60 Hz AC-3e, 1.5 kW 220...230 V AC 50/60 Hz AC-4
Operating Time10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
Protective TreatmentTC IEC 60068, TC DIN 50016
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Connections Terminals2 0.75-4 mm²flexible without cable end, 2 0.34-1.5 mm²flexible with cable endscrew clamp terminalsscrew clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable endscrew clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
Ith Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
Carbon Footprint Of The End Of Life Phase C1 To C40.25905106779138043, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A30.9 kg CO2 eq., 0.9242849543117562
Local Data StatusPublishable
Return IndicatorY
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503003
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2448
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Contactor Applicationmotor control
Device Short NameLC1K
Inrush Power In Va30-30 VA (at 20 °C)
Motor Starter Typedirect on-line contactor
Number Of Poles3P
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys K
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Data Sourceextrapolated product
Width Nominal45 mm
Customs Code8536490065
Warranty In Months18
Functional Unit Quantity1
Reference Lifetime In Y20
Recyclability Potential In %63
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Coil Voltage230 V AC standard, 220 V AC standard
Flame RetardanceV1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Mounting Supportrail, plate
Power Range0.55-1 kW 380-440 V 3 phase, 1.1-2 kW 380-440 V 3 phase, 0.55-1 kW 480-500 V 3 phase, 1.1-2 kW 480-500 V 3 phase, 2.2-3 kW 480-500 V 3 phase0-0.5 kW 200-240 V 3 phase, 0.55-1 kW 200-240 V 3 phase, 1.1-2 kW 200-240 V 3 phase, 0-0.5 kW 380-440 V 3 phase, 2.2-3 kW 380-440 V 3 phase, 0-0.5 kW 480-500 V 3 phase
Signalling Circuit Frequency<= 400 Hz, <= 400 Hz
Utilisation CategoryAC-3, AC-3e, AC-4
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Carbon Footprint Of The Distribution Phase A40.35672643587278696, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50 kg CO2 eq., 0.024523461013256826
Carbon Footprint Of The Use Phase B2 B3 B4 B657 kg CO2 eq., 56.65241524409139
Local Publishable Date2026-06-27
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Compatibility CodeLC1K
Device Applicationcontrol
Heat Dissipation1.3-1.3 W
Mechanical Durability10 Mcycles
Non Overlap Distance0.5 mm
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
RangeTeSys
ReturnabilityYes
Software Versionv6.2.4
Total Lifecycle Carbon Footprint58 kg CO2 eq.
Database Version2024-01
Height Nominal58 mm
Nbr. Of Units In Pkg.1
Hold In Power Consumption In Va4.5-4.5 VA (at 20 °C)
Functional Unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional Unit Unitunit
Energy Consumption On Product Lifetime In Kwh140.16

Environment Attributes Main

Ambient Air Temperature For Storage-50-80 °C, -50-80 °C
Reach Free ShvcYes
China Rohs RegulationX
Mercury FreeYes
Circularity ProfileENVEOLI1503003
Eu Rohs DirectiveCompliant
Operating Altitude6561.68 ft (2000 m) without derating
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-23
Psr VersionPSR-0005-ed3-2023 06 06
Take BackNo
Recycled Metal Content At Cr Level0 %
Toxic Heavy Metal FreeYes
Carbon Footprint58.21700116308057
Environmental DisclosureENVPEP1503003EN
Ip Degree Of ProtectionIP2X VDE 0106
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1503003EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys K

ETIM

ETIM 8EC000066
ETIM 10EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months
TeSys K Contactor 3-Pole 6A 220-230V AC Coil 45mm Width
TeSys K Contactor 3-Pole 6A 220-230V AC Coil 45mm Width
TeSys K Contactor 3-Pole 6A 220-230V AC Coil 45mm Width
Loading video…

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$53.68/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!