TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 0.55kW@400V. It provides full protection to motors with a rated current Ir 1.25-5A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation. To be used with a 24V AC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Documentation & Downloads

Specifications

Key Specifications

[Uc] Control Circuit Voltage
24 V AC
Range Of Product
TeSys Ultra
Product Or Component Type
advanced control unit
Thermal Overload Class
class 10 40-60 Hz -25-55 °C IEC 60947-6-2 || class 10 40-60 Hz -25-55 °C UL 508
Range
TeSys
Function Available
protection against overload and short-circuit || manual reset || earth fault protection || protection against phase failure and phase imbalance
Product Compatibility
power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B
Network Frequency
40...60 Hz
Load Type
single-phase motor
[Ue] Rated Operational Voltage690 V AC
Thermal Protection Adjustment Range1.25-5 A
Product NameTeSys Ultra
Motor Power Kw0.55 kW 400...440 V AC 50/60 Hz 1 phase
Utilisation CategoryAC-44 || AC-43 || AC-41
Tripping Threshold14.2 x Ir +/- 20 %
Product Specific Applicationbasic protection and advanced functions, communication
Device Applicationmotor control || motor protection
Device Short NameLUCC

Complementary

Product Certifications
CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Reset
manual reset
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Typical Current Consumption
140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38
Compatibility Code
LUCC
Operating Time
35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Heat Dissipation
2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Height66 mm
Fixing Modeplug-in (front face)
StandardsEN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Control Circuit Voltage Limits20...26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out
Width45 mm
Depth60 mm

Environment

Ambient Air Temperature For Operation
-25-70 °C
Non-Dissipating Shock Wave
1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Vibration Resistance
2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Immunity To Voltage Dips
70 % / 500 ms IEC 61000-4-11
Ambient Air Temperature For Storage
-40-85 °C
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Fire Resistance
960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Immunity To Microbreaks3 ms
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Protective TreatmentTH IEC 60068
Operating Altitude2000 m
Immunity To Radioelectric Fields10 V IEC 61000-4-6

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP080204EN
Pvc Free
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity Profile
ENVEOLI100414
Halogen Content Performance
Halogen free plastic parts product
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information
Eu Rohs DirectiveCompliant with Exemptions

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$284.98/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!