The Schneider Electric PowerLogic A125 offer an arc flash mitigation solution for electrical cubicles. Designed to protect a multiple electrical panels or switchboards and it can be installed in LV or MV cubicles. Based on light detection, the device can support 4 light sensors to detect the fault in different zones. Thanks to fast detection, the device will control the switching devices in shorter time thanks to high speed outputs. To avoid noisy tripping due to parasite lights, a current condition input is available as a second tripping condition. The PowerLogic A1 can be supplied by large scale range : 24 VAC to 240 VAC or 24 VDC to 240 VDC network. Product provides multiple trip outputs : 1 high speed output, 1 relay. It can be installed on DIN rail or flush panel with a mounting accessory frame REL52903.

Features

  • Arc flash mitigation protection
  • Multi-zone detection to isolate correspondant circuit
  • Current condition to avoid noisy triping
  • Multiple mechanical mounting to adapt to cubicle
  • Fast configuration with dip switches
  • High speed output for faster tripping

Documentation & Downloads

Specifications

Key Specifications

Country of OriginUnited States
Weight1136 g

Complementary Attributes

Us Rated Supply Voltage24...240 V AC/DC

Important Information Attributes

Electromagnetic Compatibilityemission tests IEC/EN 60255-26 ed. 3emission tests class A EN 55022, emission tests CISPR 22, emission tests class A EN 55011, emission tests IEC 60255-25, emission tests CISPR 11EMC immunity A IEC/EN 60255-26 ed. 3damped oscillatory wave EN/IEC 61000-4-18, electrostatic discharge level 4 EN/IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3electrical fast transient level 4 EN/IEC 61000-4-4surge immunity test level 3 EN/IEC 61000-4-5immunity to conducted interference caused by radio-electrical fields level 3 EN/IEC 61000-4-6immunity to magnetic fields EN/IEC 61000-4-8immunity to magnetic fields level 5 EN/IEC 61000-4-9, immunity to voltage dips power lines (DC) EN/IEC 61000-4-29, immunity to voltage dips EN/IEC 61000-4-11immunity to ripple EN/IEC 61000-4-17
Protection Type50ARC, arc suppression
Carbon Footprint Of The Distribution Phase A40.1374960547433251, 0.1 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50.01906032201602073, 0 kg CO2 eq.
Carbon Footprint Of The Use Phase B2 B3 B4 B6319 kg CO2 eq., 318.9889724209886
Local Publishable Date2026-02-21
Device TypeRelay, Control & Measurement - Protection relay
TraceabilityYes
Average Life Duration15 year(s)
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1803007_V3
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeNo
Rohs Eur Conformity Date2320
China Rohs In ScopeYes
With Recycled CardboardNo
Product Contributes To Saved And Avoided EmissionsNo
Control And Monitoring Typeswitchgear internal arc detection
Display TypeLED 11
Mechanical Robustnessvibrations class 2) IEC 60255-21-1shocks class 2) IEC 60255-21-2earthquakes criteria A) level 2 IEC 60255-21-3vibrations Fc) IEC 60068-2-6shocks Ea) IEC 60068-2-27
Output Current Limits20 mA 24 V DC
Product NamePowerLogic Arc
Protective Treatmentconformal coating
Range Of ProductEasergy ARC
ReturnabilityYes
Sustainable PackagingNo
Type Of Measurementarc
Database Version2023-02
Height Nominaltotal: 135 mm
Nbr. Of Units In Pkg.1
Warranty In Months18
Functional Unit DescriptionThe PowerLogic A125 arc flash protection unit is a versatile and independently operating device for bay based protection during 10 years. It has a fixed one type design, and it is optimized for use in arc protection as a stand-alone device or as part of a system.It can be used in various arc protection applications in low or medium voltage power distribution systems.
Functional Unit UnitUnit
Energy Consumption On Product Lifetime In Kwh440.628
Environmental Characteristicexposure to dry heat Bd EN/IEC 60068-2-2, exposure to cold Ad EN/IEC 60068-2-1, exposure to damp heat in service Db EN/IEC 60068-2-30exposure to damp heat in service Cab EN/IEC 60068-2-78, temperature variation Nb IEC 60068-2-14
Certificate AgencyEN/IEC 60255-1, EN 60255-27
Carbon Footprint Of The End Of Life Phase C1 To C43 kg CO2 eq., 2.958471923577504
Carbon Footprint Of The Manufacturing Phase A1 To A331 kg CO2 eq., 31.05716704603982
Local Data StatusPublishable
Return IndicatorY
ServiceabilityYes
Field Service DivisionDPIBS
Weee ScopeOut
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
China Rohs Label5
Without Single Use PlasticNo
Product Kit IdentifierN
Device Short NameA125
Energy Efficiency OptimizedFalse
Mounting Supportpanel
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typearc fault detection device
RangePowerLogic
Relay Applicationarc flash
Software Versionv6.2
Total Lifecycle Carbon Footprint353 kg CO2 eq.
Connections Terminalsremovable screw terminal block
Data Sourcereferent product
Width Nominaltotal: 70 mm
Customs Code8536490080
Packaging Weight In G182.4
Functional Unit Quantity1
Reference Lifetime In Y10
Recyclability Potential In %56

Environment Attributes Main

Ambient Air Temperature For Operation-40-65 °C, -40-65 °C
Operating Altitude<= 6561.68 ft (2000 m), <= 6561.68 ft (2000 m)
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI1803007_V3
Eu Rohs DirectiveCompliant By Exemption
Packaging Made With Recycled CardboardNo
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep CodeENVPEP1803007EN
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review
Ambient Air Temperature For Storage-40-80 °C, -40-80 °C
Take BackNo
China Rohs RegulationX
Carbon Footprint353.16116776736527
Environmental DisclosureENVPEP1803007EN
Ip Degree Of ProtectionIP20 conforming to IEC 60529
Packaging Without Single Use PlasticNo
Relative Humidity0-95 % without condensation
Pep Verification Date2025-03-19
Psr VersionPSR-0005-ed3.1-EN-2023 12 08

General Attributes

Product Or Component Typearc fault detection device
Range Of ProductEasergy ARC

ETIM

ETIM 8EC002911
ETIM 10EC002911
ETIM 9EC002911

Output Attributes

Number Of Outputs2 binary1 relay, 1 IGBT, 2 control relay

Input Attributes

Number Of Inputs3 binary1 binary current input4 arc sensor, 1 digital
Discrete Input Voltage24...240 V AC/DC 250 V)
arc protection relay, PowerLogic A125
arc protection relay, PowerLogic A125
arc protection relay, PowerLogic A125
arc protection relay, PowerLogic A125
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$1393.12/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!