TeSys K Contactor, 3 Poles, 12A, 48V AC Coil, Screw Clamp Terminals
TeSys K Contactor, 3 Poles, 12A, 48V AC Coil, Screw Clamp Terminals
TeSys K Contactor, 3 Poles, 12A, 48V AC Coil, Screw Clamp Terminals
Schneider Electric

Schneider Electric LC1K1210E7 TeSys K Contactor, 3 Poles, 12A, 48V AC Coil, Screw Clamp Terminals

  • MPN: LC1K1210E7
  • PPN: SCH-LC1K1210E7

CAD

$96.78

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

LC1K1210E7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 48V 50/60Hz AC coil and 1NO auxiliary contact. LC1K1210E7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 40V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia
Depth57 mm

Complementary Attributes

Control Circuit Type
AC 50/60 Hz
Irms Rated Making Capacity
144 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
Maximum Operating Rate
3600 cyc/h
Minimum Switching Voltage
17 V for signalling circuit
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C)
Maximum Motor Phase Current12 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Electrical Durability
1.3 Mcycles 12 A AC-3 <= 440 V, 1.3 Mcycles 12 A AC-3e <= 440 V0.3 Mcycles 20 A AC-1 <= 690 V, 0.02 Mcycles 72 A AC-4 <= 440 V
Insulation Resistance
> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw
5.5 kW 380...415 V AC 50/60 Hz AC-3e, 5.5 kW 440 V AC 50/60 Hz AC-3e, 4 kW 690 V AC 50/60 Hz AC-3e5.5 kW 380...415 V AC 50/60 Hz AC-4, 5.5 kW 440 V AC 50/60 Hz AC-4, 4 kW 690 V AC 50/60 Hz AC-43 kW 220...230 V AC 50/60 Hz AC-35.5 kW 380...415 V AC 50/60 Hz AC-3, 5.5 kW 440 V AC 50/60 Hz AC-34 kW 690 V AC 50/60 Hz AC-3, 3 kW 220...230 V AC 50/60 Hz AC-3e, 3 kW 220...230 V AC 50/60 Hz AC-4
Operating Time
10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
Signalling Circuit Frequency
<= 400 Hz, <= 400 Hz
Utilisation Category
AC-3, AC-3e, AC-1, AC-4
[Ie] Rated Operational Current
12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
[Uc] Control Circuit Voltage
AC 50/60 Hz, 48 V
[Ui] Rated Insulation Voltage
signalling circuit 600 V UL 508signalling circuit 600 V CSA C22.2 No 14power circuit 600 V UL 508power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, power circuit 600 V CSA C22.2 No 14
Carbon Footprint Of The Distribution Phase [A4]
0.35474462234016035, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0 kg CO2 eq., 0.02438721956318318
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
89 kg CO2 eq., 88.5193988188928
Local Publishable Date
2026-06-27
Stocking Flag
N
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Free of Substances of Very High Concern above the threshold
Reach Compliance Directive
Free of Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant
Rohs Eur Full Compliance Status
Compliant
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Compatibility Code
LC1K
Device Short Name
LC1K
Inrush Power In Va
30-30 VA (at 20 °C)
Non Overlap Distance
0.5 mm
Overvoltage Category
III
Product Availability
Stock - Normally stocked in distribution facility
Range
TeSys
Returnability
Yes
Software Version
v6.2.4
Total Lifecycle Carbon Footprint
90 kg CO2 eq.
Pep Code
ENVPEP1503003EN
Pep Verification Date
2026-03-23
Psr Version
PSR-0005-ed3-2023 06 06
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Manufacturing [A1-a3]
Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]
Electricity Mix; Low voltage; 2020; Europe, EU-27
Recyclability Potential In %
63
Width Nominal
45 mm
[Uimp] Rated Impulse Withstand Voltage
8 kV
Nbr. Of Units In Pkg.
1
Take-back
No
Customs Code
8536490065
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationresistive load, motor control
Flame RetardanceV1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Mounting Supportplate, rail
Protective TreatmentTC IEC 60068, TC DIN 50016
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
[Ith] Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
Connections - Terminals2 0.75-4 mm²flexible without cable end, 2 0.34-1.5 mm²flexible with cable endscrew clamp terminalsscrew clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable endscrew clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
Carbon Footprint Of The End-of-life Phase [C1 To C4]0.25761189519253946, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]0.9 kg CO2 eq., 0.9191500378989131
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503003
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2448
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Device Applicationcontrol
Heat Dissipation1.3-1.3 W
Mechanical Durability10 Mcycles
Number Of Poles3P
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys K
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh219
Energy Model - Installation [A5]No energy used
Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
Height Nominal58 mm
[Icw] Rated Short-time Withstand Current115 A 50 °C - 1 s for power circuit105 A 50 °C - 5 s for power circuit100 A 50 °C - 10 s for power circuit75 A 50 °C - 30 s for power circuit55 A 50 °C - 1 min for power circuit50 A 50 °C - 3 min for power circuit25 A 50 °C - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
Hold-in Power Consumption In Va4.5-4.5 VA (at 20 °C)
Package Weight(Lbs)179.0 g
Warranty (In Months)18

Environment Attributes Main

Ambient Air Temperature For Storage
-50-80 °C, -50-80 °C
Reach Free Shvc
Yes
China Rohs Regulation
X
Mercury Free
Yes
Circularity Profile
ENVEOLI1503003
Eu Rohs Directive
Compliant
Operating Altitude
6561.68 ft (2000 m) without derating
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2026-03-23
Psr Version
PSR-0005-ed3-2023 06 06
Take BackNo
Recycled Metal Content At Cr Level0 %
Toxic Heavy Metal FreeYes
Carbon Footprint90.0752925938876
Environmental DisclosureENVPEP1503003EN
Ip Degree Of ProtectionIP2X VDE 0106
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1503003EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys K

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$96.78/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!