TeSys K Contactor 3P 6A 110V AC Coil 45mm Wide
TeSys K Contactor 3P 6A 110V AC Coil 45mm Wide
TeSys K Contactor 3P 6A 110V AC Coil 45mm Wide
Schneider Electric

Schneider Electric LC1K0610F7 TeSys K Contactor 3P 6A 110V AC Coil 45mm Wide

  • MPN: LC1K0610F7
  • PPN: SCH-LC1K0610F7

CAD

$53.68

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

LC1K0610F7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 110V 50/60Hz AC coil and 1NO auxiliary contact. LC1K0610F7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 110V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Features

  • Measuring just 45mm in width and 58mm in height, this ultra-compact TeSys K series motor contactor is one of the smallest footprints available on the industrial market. It integrates seamlessly into tightly packed automation enclosures and distribution panels, maximizing your remaining DIN rail space and preventing the need to specify a larger, more costly cabinet footprint.
  • Engineered with a 3-pole Normally Open (3 NO) power contact layout, this device reliably switches inductive operational currents up to 6A under AC-3 and AC-3e utilization categories. It delivers optimized motor management capacity up to 2.2 kW at 380-415V or 3 kW at 440V, allowing industrial electricians to establish dependable Direct-On-Line (DOL) starters for small asynchronous pumps, conveyors, and automated fans.
  • Equipped with a standard 110V AC control coil optimized for both 50 Hz and 60 Hz frequencies, this device integrates directly into common plant control loops and transformer circuits. The robust coil design features a secure drop-out threshold of 0.2 Uc and holds in at a highly efficient 4.5 VA, preventing excessive localized heat generation while safely absorbing momentary line drops to avoid nuisance machinery downtime.
  • Built with a factory-integrated, instantaneous Normally Open (1 NO) auxiliary contact block, this controller eliminates the cost and space of installing add-on signaling contacts. Operating down to a minimum switching threshold of 17V at 5mA, it guarantees precise, low-energy state feedback to your primary programmable logic controllers or status pilot lights for reliable plant-floor safety monitoring.
  • Boasting an exceptional mechanical durability rating of up to 10 million cycles alongside 1.3 million electrical cycles at full AC-3 load, this industrial-grade component drastically lowers future replacement intervals.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia, ZZ
Depth57 mm

Complementary Attributes

Irms Rated Making Capacity
110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Control Circuit Type
AC 50/60 Hz
Maximum Motor Phase Current
6 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C)
Maximum Operating Rate3600 cyc/h
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Flame Retardance
V1 conforming to UL 94requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mechanical Robustness
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Mounting Support
plate, rail
Power Range
0.55-1 kW 380-440 V 3 phase, 1.1-2 kW 380-440 V 3 phase, 0.55-1 kW 480-500 V 3 phase, 1.1-2 kW 480-500 V 3 phase, 2.2-3 kW 480-500 V 3 phase0-0.5 kW 200-240 V 3 phase, 0.55-1 kW 200-240 V 3 phase, 1.1-2 kW 200-240 V 3 phase, 0-0.5 kW 380-440 V 3 phase, 2.2-3 kW 380-440 V 3 phase, 0-0.5 kW 480-500 V 3 phase
Signalling Circuit Frequency
<= 400 Hz, <= 400 Hz
Utilisation Category
AC-3, AC-3e, AC-4
[Icw] Rated Short-time Withstand Current
90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current
20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
[Ue] Rated Operational Voltage
power circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
Connections - Terminals
2 0.75-4 mm²flexible without cable end, 2 0.34-1.5 mm²flexible with cable endscrew clamp terminalsscrew clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable endscrew clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
Carbon Footprint Of The End-of-life Phase [C1 To C4]
0.25905106779138043, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
0.9 kg CO2 eq., 0.9242849543117562
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1503003
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
2448
China Rohs Label
1
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Coil Technology
without built-in suppressor module
Contactor Application
motor control
Device Application
control
Heat Dissipation
1.3-1.3 W
Mechanical Durability
10 Mcycles
Non Overlap Distance
0.5 mm
Overvoltage Category
III
Product Availability
Stock - Normally stocked in distribution facility
Range
TeSys
Returnability
Yes
Software Version
v6.2.4
Total Lifecycle Carbon Footprint
50 kg CO2 eq.
Pep Code
ENVPEP1503003EN
Pep Verification Date
2026-03-23
Psr Version
PSR-0005-ed3-2023 06 06
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Manufacturing [A1-a3]
Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]
Electricity Mix; Low voltage; 2020; Europe, EU-27
Recyclability Potential In %
63
Width Nominal
45 mm
Hold-in Power Consumption In Va
4.5-4.5 VA (at 20 °C)
Package Weight(Lbs)
179.0 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability1.3 Mcycles 6 A AC-3 <= 440 V, 1.3 Mcycles 6 A AC-3e <= 440 V, 0.05 Mcycles 36 A AC-4 <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw2.2 kW 380...415 V AC 50/60 Hz AC-3e, 3 kW 440/690 V AC 50/60 Hz AC-3e2.2 kW 380...415 V AC 50/60 Hz AC-4, 3 kW 440/690 V AC 50/60 Hz AC-41.5 kW 220...230 V AC 50/60 Hz AC-32.2 kW 380...415 V AC 50/60 Hz AC-33 kW 440/690 V AC 50/60 Hz AC-3, 1.5 kW 220...230 V AC 50/60 Hz AC-3e, 1.5 kW 220...230 V AC 50/60 Hz AC-4
Operating Time10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
Protective TreatmentTC IEC 60068, TC DIN 50016
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
[Ie] Rated Operational Current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control Circuit VoltageAC 50/60 Hz, 110 V
[Ui] Rated Insulation Voltagesignalling circuit 600 V UL 508signalling circuit 600 V CSA C22.2 No 14power circuit 600 V UL 508power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, power circuit 600 V CSA C22.2 No 14
Carbon Footprint Of The Distribution Phase [A4]0.35672643587278696, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.024523461013256826
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]49 kg CO2 eq., 48.898115907556374
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Compatibility CodeLC1K
Contactor Coil Voltage110 V AC standard
Device Short NameLC1K
Inrush Power In Va30-30 VA (at 20 °C)
Motor Starter Typedirect on-line contactor
Number Of Poles3P
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys K
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh120.9756
Energy Model - Installation [A5]No energy used
Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
Height Nominal58 mm
[Uimp] Rated Impulse Withstand Voltage8 kV
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

Ambient Air Temperature For Storage
-50-80 °C, -50-80 °C
Reach Free Shvc
Yes
China Rohs Regulation
X
Mercury Free
Yes
Circularity Profile
ENVEOLI1503003
Eu Rohs Directive
Compliant
Operating Altitude
6561.68 ft (2000 m) without derating
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2026-03-23
Psr Version
PSR-0005-ed3-2023 06 06
Take BackNo
Recycled Metal Content At Cr Level0 %
Toxic Heavy Metal FreeYes
Carbon Footprint50.462701826545555
Environmental DisclosureENVPEP1503003EN
Ip Degree Of ProtectionIP2X VDE 0106
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1503003EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys K

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months