TeSys K Contactor 3P 6A 110V AC Coil 45mm Wide
Schneider Electric

Schneider Electric LC1K0610F7 TeSys K Contactor 3P 6A 110V AC Coil 45mm Wide

  • MPN: LC1K0610F7
  • PPN: SCH-LC1K0610F7

CAD

$53.68

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 110V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Features

  • Measuring just 45mm in width and 58mm in height, this ultra-compact TeSys K series motor contactor is one of the smallest footprints available on the industrial market. It integrates seamlessly into tightly packed automation enclosures and distribution panels, maximizing your remaining DIN rail space and preventing the need to specify a larger, more costly cabinet footprint.
  • Engineered with a 3-pole Normally Open (3 NO) power contact layout, this device reliably switches inductive operational currents up to 6A under AC-3 and AC-3e utilization categories. It delivers optimized motor management capacity up to 2.2 kW at 380-415V or 3 kW at 440V, allowing industrial electricians to establish dependable Direct-On-Line (DOL) starters for small asynchronous pumps, conveyors, and automated fans.
  • Equipped with a standard 110V AC control coil optimized for both 50 Hz and 60 Hz frequencies, this device integrates directly into common plant control loops and transformer circuits. The robust coil design features a secure drop-out threshold of 0.2 Uc and holds in at a highly efficient 4.5 VA, preventing excessive localized heat generation while safely absorbing momentary line drops to avoid nuisance machinery downtime.
  • Built with a factory-integrated, instantaneous Normally Open (1 NO) auxiliary contact block, this controller eliminates the cost and space of installing add-on signaling contacts. Operating down to a minimum switching threshold of 17V at 5mA, it guarantees precise, low-energy state feedback to your primary programmable logic controllers or status pilot lights for reliable plant-floor safety monitoring.
  • Boasting an exceptional mechanical durability rating of up to 10 million cycles alongside 1.3 million electrical cycles at full AC-3 load, this industrial-grade component drastically lowers future replacement intervals.

Documentation & Downloads

Specifications

Key Specifications

Contactor Application
motor control
Range
TeSys
Device Short Name
LC1K
Product Or Component Typecontactor
Device Applicationcontrol

Complementary

Minimum Switching Current
5 mA for signalling circuit
[Uc] Control Circuit Voltage
110 V AC 50/60 Hz
Height
58 mm
Auxiliary Contact Composition
1 NO
Non Overlap Distance
0.5 mm
Mounting Support
plate || rail
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Motor Power Kw
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC 50/60 Hz AC-4 || 2.2 kW 380...415 V AC 50/60 Hz AC-4 || 3 kW 440/690 V AC 50/60 Hz AC-4
Net Weight
0.18 kg
Inrush Power In Va
30-30 VA (at 20 °C)
Pole Contact Composition
3 NO
[Ie] Rated Operational Current
6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Maximum Operating Rate
3600 cyc/h
Electrical Durability
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Auxiliary Contacts Type
instantaneous 1 NO
Hold-In Power Consumption In Va
4.5-4.5 VA (at 20 °C)
Width
45 mm
Overvoltage Category
III
[Ui] Rated Insulation Voltage
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
Heat Dissipation
1.3-1.3 W
Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Ue] Rated Operational Voltagepower circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
[Ith] Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Control Circuit TypeAC 50/60 Hz
Insulation Resistance> 10 MOhm for signalling circuit
Irms Rated Making Capacity110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Associated Fuse Rating25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
[Uimp] Rated Impulse Withstand Voltage8 kV
Connections - Terminalsscrew clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Utilisation CategoryAC-3 || AC-3e || AC-4
Minimum Switching Voltage17 V for signalling circuit
Signalling Circuit Frequency<= 400 Hz
Mechanical Durability10 Mcycles
Poles Description3P
Operating Time10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Depth57 mm
[Icw] Rated Short-Time Withstand Current90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit

Environment

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Flame Retardance
V1 UL 94 || requirement 2 NF F 16-101 || requirement 2 NF F 16-102
Protective Treatment
TC IEC 60068 || TC DIN 50016
Operating Altitude
2000 m without derating
StandardsEN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Ambient Air Temperature For Storage-50-80 °C
Ip Degree Of ProtectionIP2X VDE 0106

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1503003EN
Toxic Heavy Metal Free
Yes
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive
Compliant
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationFree of Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity ProfileENVEOLI1503003EN

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$53.68/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!