TeSys K Contactor 3P 9A 220...230V AC Coil 1NC Aux 45mm Width
Schneider Electric

Schneider Electric LC1K0901M7 TeSys K Contactor 3P 9A 220...230V AC Coil 1NC Aux 45mm Width

  • MPN: LC1K0901M7
  • PPN: SCH-LC1K0901M7

CAD

$67.75

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Documentation & Downloads

Specifications

Key Specifications

Contactor Application
motor control || resistive load
Range
TeSys
Device Short Name
LC1K
Product Or Component Typecontactor
Device Applicationcontrol

Complementary

Minimum Switching Current
5 mA for signalling circuit
[Uc] Control Circuit Voltage
220...230 V AC 50/60 Hz
Height
58 mm
Auxiliary Contact Composition
1 NC
Non Overlap Distance
0.5 mm
Control Circuit Type
AC 50/60 Hz
Insulation Resistance
> 10 MOhm for signalling circuit
Irms Rated Making Capacity
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Associated Fuse Rating
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
Inrush Power In Va
30-30 VA (at 20 °C)
Pole Contact Composition
3 NO
[Ie] Rated Operational Current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Maximum Operating Rate
3600 cyc/h
Electrical Durability
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Auxiliary Contacts Type
instantaneous 1 NC
Hold-In Power Consumption In Va
4.5-4.5 VA (at 20 °C)
Width
45 mm
Depth
57 mm
Heat Dissipation
1.3-1.3 W
Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Ue] Rated Operational Voltagepower circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
[Ith] Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Motor Power Kw2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/60 Hz AC-4 || 4 kW 380...415 V AC 50/60 Hz AC-4 || 4 kW 440/690 V AC 50/60 Hz AC-4
[Uimp] Rated Impulse Withstand Voltage8 kV
Connections - Terminalsscrew clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Utilisation CategoryAC-3 || AC-3e || AC-1 || AC-4
Minimum Switching Voltage17 V for signalling circuit
Signalling Circuit Frequency<= 400 Hz
Mechanical Durability10 Mcycles
Poles Description3P
Operating Time10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Overvoltage CategoryIII
[Icw] Rated Short-Time Withstand Current90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit

Environment

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Flame Retardance
V1 UL 94 || requirement 2 NF F 16-101 || requirement 2 NF F 16-102
Operating Altitude
2000 m without derating
StandardsEN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Protective TreatmentTC IEC 60068 || TC DIN 50016

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1503003EN
Toxic Heavy Metal Free
Yes
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive
Compliant
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationFree of Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity ProfileENVEOLI1503003EN

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$67.75/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!