TeSys Deca Reversing Contactor 3 Pole 18A 120V AC Coil
Schneider Electric

Schneider Electric LC2D18G7V TeSys Deca Reversing Contactor 3 Pole 18A 120V AC Coil

  • MPN: LC2D18G7V
  • PPN: SCH-LC2D18G7V

CAD

$602.57

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys Deca contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A reversing inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 3.54 inches wide and 3.39 inches deep. It weighs 1.56 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
France, United States
Depth86 mm

Complementary Attributes

Control Circuit Type
AC 50/60 Hz, AC 50/60 Hz
Maximum Horse Power Rating
5 hp at 230/240 V AC 60 Hz for 3 phase motors1 hp at 115 V AC 60 Hz for 1 phase motors3 hp at 230/240 V AC 60 Hz for 1 phase motors, 5 hp at 200/208 V AC 60 Hz for 3 phase motors10 hp at 460/480 V AC 60 Hz for 3 phase motors15 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Motor Phase Current
18 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
300 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1300 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate3600 cyc/h 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Contactor Application
motor control, resistive load
Inrush Power In Va
70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
Mounting Support
plate, rail
Range
TeSys, TeSys Deca
Tightening Torque
control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Control Circuit Voltage
120 V
[Uc] Control Circuit Voltage
120 V, 120 V AC 50/60 Hz
Connections - Terminals
control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endcontrol circuit screw clamp terminals 2 1-4 mm²solidpower circuit screw clamp terminals 2 1.5-6 mm²flexible without cable endpower circuit screw clamp terminals 1 1-6 mm²flexible with cable endpower circuit screw clamp terminals 2 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1.5-6 mm²solid, power circuit screw clamp terminals 2 1.5-6 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solidpower circuit screw clamp terminals 1 1.5-6 mm²flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]
0.32769104473917116, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
3 kg CO2 eq., 2.931974644601296
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1501004
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
2538
China Rohs In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-150 A gG at <= 690 V coordination type 1 for power circuit35 A gG at <= 690 V coordination type 2 for power circuit
Coil Technology
without built-in suppressor module
Contact Compatibility
M2
Fire Resistance
850 °C IEC 60695-2-1
Heat Dissipation
2-3 W 50/60 Hz
Mechanical Durability
15 Mcycles
Operating Time
12...22 ms closing4...19 ms opening
Pole Contact Composition
3 NO
Product Availability
Stock - Normally stocked in distribution facility
Protective Treatment
TH IEC 60068-2-30
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Version
v6.2.4
Total Lifecycle Carbon Footprint
52 kg CO2 eq.
Inf Motor Phase Current
18 A
Database Version
2024-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unit
unit
Energy Consumption On Product Lifetime In Kwh
543.12
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
77 mm
[Icw] Rated Short-time Withstand Current
40 A 40 °C - 10 min for power circuit84 A 40 °C - 1 min for power circuit145 A 40 °C - 10 s for power circuit240 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit32 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Rated Thermal Current (Ith)
32 A
Package Weight(Lbs)
730.0 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability1.65 Mcycles 18 A AC-3 <= 440 V, 1 Mcycles 32 A AC-1 <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw4 kW at 220...230 V AC 50 Hz7.5 kW at 380...400 V AC 50 Hz9 kW at 415...440 V AC 50 Hz10 kW at 500 V AC 50 Hz, 10 kW at 660...690 V AC 50 Hz
Product NameTeSys D, TeSys Deca
Range Of ProductTeSys D, TeSys Deca
Utilisation CategoryAC-3, AC-1
Certificate AgencyDNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.11547926448314888
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]49 kg CO2 eq., 48.85022504616
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Average Impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Compatibility CodeLC2D
Device Short NameLC2D
Flame RetardanceV1 conforming to UL 94
Interlocking Typeelectrical and mechanical
Number Of Poles3P
Overvoltage CategoryIII
Power Dissipation Per Pole0.8 W AC-32.5 W AC-1
Product Or Component Typereversing contactor
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep CodeENVPEP1501004EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %66
Width Nominal90 mm
[Ie] Rated Operational Current18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In Va7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Climatic Withstand
IACS E10, IEC 60947-1 Annex Q category D
Reach Free Shvc
Yes
Toxic Heavy Metal Free
Yes
Carbon Footprint
52.22536999998361
Circularity Profile
ENVEOLI1501004
Eu Rohs Directive
Compliant
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2026-03-17
Psr Version
PSR-0005-ed3-2023 06 06
Ambient Air Temperature For Storage-60-80 °C, -60-80 °C
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Ambient Air Temperature For Operation-40-60 °C-40-60 °C60-70 °C with derating
Environmental DisclosureENVPEP1501004EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1501004EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Range Of Product
TeSys D, TeSys Deca
Product Or Component Typereversing contactor

ETIM

ETIM 8
EC000010
ETIM 9EC000010

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Overview Attributes

Device Presentation
preassembled with reversing power busbar

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$602.57/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!