Reversing contactor, TeSys Deca Advanced, 3P(3NO), AC-3/3e, <=440V, 12A, 100...250V AC/DC coil, screw clamp terminals
Schneider Electric

Schneider Electric LC2D12KUE Reversing contactor, TeSys Deca Advanced, 3P(3NO), AC-3/3e, <=440V, 12A, 100...250V AC/DC coil, screw clamp terminals

  • MPN: LC2D12KUE
  • PPN: SCH-LC2D12KUE

CAD

$731.74

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V). Rated 12A AC-3 5.5kW@400V, it includes a 100-250V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 12A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
France
Depth86 mm

Physical Attributes

Color
Gray SE GREY 6)Green SE GREEN 2)

Complementary Attributes

Control Circuit Type
AC 50/60 Hz AC/DC electronic, DC AC/DC electronic, AC 50/60 Hz AC/DC electronic, DC AC/DC electronic
Irms Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Motor Phase Current
12 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC0.85...1.1 Uc (-40-60 °C):operational AC/DC1...1.1 Uc (60-70 °C):operational AC/DC
Maximum Horse Power Rating3 hp at 230/240 V AC 60 Hz for 3 phase motors0.5 hp at 115 V AC 60 Hz for 1 phase motors2 hp at 230/240 V AC 60 Hz for 1 phase motors, 3 hp at 200/208 V AC 60 Hz for 3 phase motors7.5 hp at 460/480 V AC 60 Hz for 3 phase motors10 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Operating Rate3600 cyc/h 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Contactor Application
resistive load, motor control
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
Mounting Support
rail, plate
Utilisation Category
AC-1, AC-3
[Uc] Control Circuit Voltage
100...250 V, 100...250 V AC 50/60 Hz, 100...250 V DC
Non-overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]
1.3569948749760874, 1 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
7 kg CO2 eq., 6.551697265899829
Local Data Status
Publishable
Return Indicator
N
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1609001EN
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
1922
China Rohs In Scope
No
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Compatibility Code
LC2D
Fire Resistance
850 °C IEC 60695-2-1
Interlocking Type
mechanical
Overvoltage Category
III
Power Dissipation Per Pole
1.56 W AC-10.36 W AC-3
Product Name
TeSys Deca Advanced
Protective Treatment
TH IEC 60068-2-30
Returnability
No
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep Code
ENVPEP1609001EN
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Manufacturing [A1-a3]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - Use [B6]
Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential In %
70
Width Nominal
90 mm
[Ie] Rated Operational Current
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Halogen-free Status
Halogen free plastic parts and cables product
Package Weight(Lbs)
880.0 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw3 kW at 220...230 V AC 50 Hz5.5 kW at 380...400 V AC 50 Hz, 5.5 kW at 415 V AC 50 Hz, 5.5 kW at 440 V AC 50 Hz7.5 kW at 500 V AC 50 Hz, 7.5 kW at 660...690 V AC 50 Hz
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Control Circuit Voltage100...250 V
Connections - Terminalspower circuit screw clamp terminals 2 1-2.5 mm²flexible with cable endpower circuit screw clamp terminals 2 1-4 mm²solidcontrol circuit screw clamp terminals 2 1-4 mm²flexible without cable endcontrol circuit screw clamp terminals 1 1-4 mm²flexible with cable endcontrol circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end, power circuit screw clamp terminals 2 1-4 mm²flexible without cable end, power circuit screw clamp terminals 1 1-4 mm²flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.23655117366805578, 0.2 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.08830320362798136
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]16 kg CO2 eq., 16.036787368421056
Local Publishable Date2026-06-27
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit25 A gG at <= 690 V coordination type 2 for power circuit
Coil Technologybuilt-in bidirectional peak limiting
Device Short NameLC2D
Flame RetardanceV1 conforming to UL 94
Number Of Poles3P
Pole Contact Composition3 NO
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Product Or Component Typereversing contactor
Range Of ProductTeSys Deca Advanced
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv5.9.4
Total Lifecycle Carbon Footprint24 kg CO2 eq.
Inf Motor Phase Current12 A
Database Version2022-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionSwitch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3 NO, a control circuit voltage 250V, a power circuit voltage 690V and a rated operational current 9A.
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh240.024
Energy Model - Installation [A5]Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]Electricity Mix; Production mix; Low voltage; FR
Height Nominal77 mm
[Icw] Rated Short-time Withstand Current105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit25 A (at 60 °C) for power circuit
[Ui] Rated Insulation Voltagepower circuit 690 V IEC 60947-4-1signalling circuit 690 V IEC 60947-1
Rated Thermal Current (Ith)25 A
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Climatic Withstand
IACS E10, IEC 60947-1 Annex Q category D
Halogene Performance
Halogen free plastic parts & cables product
Mercury Free
Yes
Ambient Air Temperature For Operation
-40-60 °C-40-60 °C60-70 °C with derating
Environmental Disclosure
ENVPEP1609001EN
Halogen Content Performance
Halogen free plastic parts & cables product
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Pep Code
ENVPEP1609001EN
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Ambient Air Temperature For Storage-60-80 °C, -60-80 °C
Take BackNo
Recycled Metal Content At Cr Level0 %
Carbon Footprint24.270333886593008
Circularity ProfileENVEOLI1609001EN
Eu Rohs DirectiveCompliant By Exemption
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29

General Attributes

Product Or Component Type
reversing contactor
Range Of ProductTeSys Deca Advanced

ETIM

ETIM 8
EC000010
ETIM 9EC000010

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Overview Attributes

Device Presentation
preassembled with reversing power busbar

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$731.74/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!