TeSys Deca Contactor 3P 50A 110V AC 3600 cyc/h IP20
TeSys Deca Contactor 3P 50A 110V AC 3600 cyc/h IP20
Schneider Electric

Schneider Electric LC1D50AF7 TeSys Deca Contactor 3P 50A 110V AC 3600 cyc/h IP20

  • MPN: LC1D50AF7
  • PPN: SCH-LC1D50AF7

CAD

$426.91

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 50A/440V AC-3/3e (22kW@400V). They can be used to create motor starters for almost any type of application. It provides a 110V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia, India, United States
Depth120 mm

Complementary Attributes

Control Circuit Type
AC 50/60 Hz standard, AC 50/60 Hz standard
Maximum Horse Power Rating
15 hp at 230/240 V AC 50/60 Hz for 3 phase motors3 hp at 115 V AC 50/60 Hz for 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Maximum Motor Phase Current
50 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
900 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1900 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
1.45 Mcycles 50 A AC-3 <= 440 V, 1.1 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 50 A AC-3e <= 440 V
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms)
Mounting Support
rail, plate
Range
TeSys, TeSys Deca
Utilisation Category
AC-3, AC-3e, AC-1, AC-4
Certificate Agency
CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
[Uc] Control Circuit Voltage
110 V, 110 V AC 50/60 Hz
Connections - Terminals
control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endEverLink BTR screw connectorscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]
0.39628832143138804, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0.1 kg CO2 eq., 0.05161992301876894
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
61 kg CO2 eq., 61.259758021595786
Local Publishable Date
2026-06-27
Stocking Flag
N
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant
Rohs Eur Full Compliance Status
Compliant
China Rohs Label
1
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Coil Technology
without built-in suppressor module
Contact Compatibility
M2
Fire Resistance
850 °C IEC 60695-2-1
Inrush Power In Va
140-140 VA 60 Hz cos phi 0.75 (at 20 °C)160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
Number Of Poles
3P
Overvoltage Category
III
Product Availability
Stock - Normally stocked in distribution facility
Protective Treatment
THIEC 60068-2-30
Returnability
Yes
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inf Motor Phase Current
50 A
Database Version
2024-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unit
unit
Energy Consumption On Product Lifetime In Kwh
681.09
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
122 mm
[Icw] Rated Short-time Withstand Current
400 A 40 °C - 10 s for power circuit810 A 40 °C - 1 s for power circuit84 A 40 °C - 10 min for power circuit208 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In Va
13-13 VA 60 Hz cos phi 0.3 (at 20 °C)15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
Package Weight(Lbs)
925.000 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw22 kW at 380/400 V AC 50/60 Hz (AC-3e), 25 kW at 415 V AC 50/60 Hz (AC-3e), 30 kW at 440 V AC 50/60 Hz (AC-3e), 30 kW at 500 V AC 50/60 Hz (AC-3e), 33 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 220/230 V AC 50/60 Hz (AC-3)22 kW at 380/400 V AC 50/60 Hz (AC-3)25 kW at 415 V AC 50/60 Hz (AC-3)30 kW at 440 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3)33 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4)
Power Dissipation Per Pole3.7 W AC-39.6 W AC-1, 3.7 W AC-3e
Tightening Torquecontrol circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2
Control Circuit Voltage110 V
[Ie] Rated Operational Current50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]1.2010967322350512, 1 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]4 kg CO2 eq., 4.227273078780573
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503009EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1926
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Heat Dissipation4-5 W at 50/60 Hz
Mechanical Durability6 Mcycles
Operating Time4...19 ms opening12...26 ms closing
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Total Lifecycle Carbon Footprint67 kg CO2 eq.
Connections TerminalsEverLink BTR screw connectors
Pep CodeENVPEP1503009EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %62
Width Nominal55 mm
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take Back
No
Toxic Heavy Metal Free
Yes
Carbon Footprint
67.13603607706158
Environmental Disclosure
ENVPEP1503009EN
Ip Degree Of Protection
IP20 front face IEC 60529
Packaging Made With Recycled Cardboard
Yes
Permissible Ambient Air Temperature Around The Device
-40-60 °C-40-60 °C60-70 °C with derating
Pep Code
ENVPEP1503009EN
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI1503009EN
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months
Loading video…

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$426.91/ EA

Loading add to cart quantity...

banner

Need assistance?