Schneider Electric LC1D65AG7 TeSys Deca Contactor 3P 65A 120V AC Coil, Compact 55mm Width
- MPN: LC1D65AG7
- PPN: SCH-LC1D65AG7
CAD
$506.98
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Features
- Designed for AC-3 applications up to 65A (30kW at 400V), this 3-pole contactor is engineered to manage the intense electrical demands of industrial pumps, fans, and compressors. Its high-durability construction ensures a long mechanical life, reducing maintenance intervals and preventing costly production stops in demanding manufacturing environments.
- Featuring a high-efficiency G7-coded 120V AC coil, this unit integrates seamlessly with standard North American industrial control voltage standards. The coil is optimized for low power consumption during hold, minimizing heat generation within your enclosure and protecting sensitive adjacent electronic components from thermal stress.
- Equipped with built-in 1 NO (Normally Open) and 1 NC (Normally Closed) auxiliary contacts as standard, this contactor provides immediate feedback to your PLC or control system. These integrated contacts allow for easy implementation of electrical interlocking and status monitoring without the added expense or physical footprint of snap-on accessory blocks.
- Utilizing Schneider Electric s patented EverLink BTR screw technology, this contactor maintains consistent pressure on power cables even as wires "creep" or cold-flow over time. This permanent tightening technology eliminates the need for periodic re-torqueing, significantly reducing the risk of overheating at the terminals and preventing localized electrical fires.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, Costa Rica, France, Indonesia, United States |
|---|
| Depth | 120 mm |
|---|
Complementary Attributes
| Control Circuit Type | AC 60 Hz, AC 60 Hz |
|---|---|
| Control Circuit Voltage Limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 60 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 60 Hz |
| Maximum Motor Phase Current | 65 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Horse Power Rating | 20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 1 phase motors20 hp at 200/208 V AC 50/60 Hz for 3 phase motors50 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
|---|---|
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11000 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit |
| Electrical Durability | 1.4 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 65 A AC-3 <= 440 V, 1.45 Mcycles 65 A AC-3e <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms) |
| Mounting Support | rail, plate |
| Range | TeSys, TeSys Deca |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Certificate Agency | CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC |
| [Uc] Control Circuit Voltage | 120 V, 120 V AC 60 Hz |
| Connections - Terminals | control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endEverLink BTR screw connectorscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end |
| Carbon Footprint Of The Distribution Phase [A4] | 0.39860579699531423, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0.1 kg CO2 eq., 0.05192179391361554 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 77 kg CO2 eq., 76.62394170546868 |
| Local Publishable Date | 2026-06-27 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | without built-in suppressor module |
| Contact Compatibility | M2 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Inrush Power In Va | 140-140 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Inf Motor Phase Current | 65 A |
| Database Version | 2024-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 851.91 |
| Energy Model - Installation [A5] | No energy used |
| Energy Model - End Of Life [C1-c4] | Global, European and French datasets are used. |
| Height Nominal | 122 mm |
| [Icw] Rated Short-time Withstand Current | 640 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
| Hold-in Power Consumption In Va | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Package Weight(Lbs) | 943 g |
| Warranty (In Months) | 18 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Contactor Application | motor control, resistive load |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 30 kW at 380/400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660/690 V AC 50/60 Hz (AC-3e), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3)30 kW at 380/400 V AC 50/60 Hz (AC-3)37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660/690 V AC 50/60 Hz (AC-3), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 9.6 W AC-16.3 W AC-3, 6.3 W AC-3e |
| Tightening Torque | control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2 |
| Control Circuit Voltage | 120 V |
| [Ie] Rated Operational Current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1 |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 1.2081206897335017, 1 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 4 kg CO2 eq., 4.251993973978119 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503009EN |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 1926 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Heat Dissipation | 4-5 W at 60 Hz |
| Mechanical Durability | 6 Mcycles |
| Operating Time | 4...19 ms opening12...26 ms closing |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Total Lifecycle Carbon Footprint | 83 kg CO2 eq. |
| Connections Terminals | EverLink BTR screw connectors |
| Pep Code | ENVPEP1503009EN |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Low voltage; 2020; France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2020; France, FR |
| Recyclability Potential In % | 62 |
| Width Nominal | 55 mm |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536490065 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Take Back | No |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 82.53458396008924 |
| Environmental Disclosure | ENVPEP1503009EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Pep Code | ENVPEP1503009EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503009EN |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|


Accessories
Loading carousel layout...
Loading carousel layout...
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$506.98
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$506.98/ EA
Loading add to cart quantity...