TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A/440V AC-3/3e (30kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Features

  • Designed for AC-3 applications up to 65A (30kW at 400V), this 3-pole contactor is engineered to manage the intense electrical demands of industrial pumps, fans, and compressors. Its high-durability construction ensures a long mechanical life, reducing maintenance intervals and preventing costly production stops in demanding manufacturing environments.
  • Featuring a high-efficiency G7-coded 120V AC coil, this unit integrates seamlessly with standard North American industrial control voltage standards. The coil is optimized for low power consumption during hold, minimizing heat generation within your enclosure and protecting sensitive adjacent electronic components from thermal stress.
  • Equipped with built-in 1 NO (Normally Open) and 1 NC (Normally Closed) auxiliary contacts as standard, this contactor provides immediate feedback to your PLC or control system. These integrated contacts allow for easy implementation of electrical interlocking and status monitoring without the added expense or physical footprint of snap-on accessory blocks.
  • Utilizing Schneider Electric s patented EverLink BTR screw technology, this contactor maintains consistent pressure on power cables even as wires "creep" or cold-flow over time. This permanent tightening technology eliminates the need for periodic re-torqueing, significantly reducing the risk of overheating at the terminals and preventing localized electrical fires.

Documentation & Downloads

Specifications

Key Specifications

Country of OriginUnited States
Depth120 mm
Weight860 g

Complementary Attributes

Control Circuit TypeAC 60 Hz, AC 60 Hz
Ie Rated Operational Current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Ui Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11000 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit
Icw Rated Short Time Withstand Current640 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Uimp Rated Impulse Withstand Voltage6 kV IEC 60947
Maximum Horse Power Rating20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 1 phase motors20 hp at 200/208 V AC 50/60 Hz for 3 phase motors50 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Uc Control Circuit Voltage120 V, 120 V AC 60 Hz
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 60 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 60 Hz
Maximum Motor Phase Current65 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity1000 A at 440 V for power circuit conforming to IEC 60947
Ue Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability1.4 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 65 A AC-3 <= 440 V, 1.45 Mcycles 65 A AC-3e <= 440 V
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms)
Mounting Supportrail, plate
RangeTeSys, TeSys Deca
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
Control Circuit Voltage120 V
Non Overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End Of Life Phase C1 To C41.2081206897335017, 1 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A34 kg CO2 eq., 4.251993973978119
Local Data StatusPublishable
Return IndicatorY
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503009EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1926
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Heat Dissipation4-5 W at 60 Hz
Mechanical Durability6 Mcycles
Operating Time4...19 ms opening12...26 ms closing
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Total Lifecycle Carbon Footprint83 kg CO2 eq.
Inf Motor Phase Current65 A
Data Sourceextrapolated product
Width Nominal55 mm
Customs Code8536490065
Hold In Power Consumption In Va13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
Functional Unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional Unit Unitunit
Energy Consumption On Product Lifetime In Kwh851.91
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw30 kW at 380/400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660/690 V AC 50/60 Hz (AC-3e), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3)30 kW at 380/400 V AC 50/60 Hz (AC-3)37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660/690 V AC 50/60 Hz (AC-3), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4)
Power Dissipation Per Pole9.6 W AC-16.3 W AC-3, 6.3 W AC-3e
Tightening Torquecontrol circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2
Connections Terminalscontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end, EverLink BTR screw connectors
Certificate AgencyCCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
Carbon Footprint Of The Distribution Phase A40.39860579699531423, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50.1 kg CO2 eq., 0.05192179391361554
Carbon Footprint Of The Use Phase B2 B3 B4 B677 kg CO2 eq., 76.62394170546868
Local Publishable Date2026-06-27
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Contact CompatibilityM2
Fire Resistance850 °C IEC 60695-2-1
Inrush Power In Va140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
Number Of Poles3P
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Database Version2024-01
Height Nominal122 mm
Nbr. Of Units In Pkg.1
Ith Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit
Warranty In Months18
Functional Unit Quantity1
Reference Lifetime In Y20
Recyclability Potential In %62

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take BackNo
Toxic Heavy Metal FreeYes
Carbon Footprint82.53458396008924
Environmental DisclosureENVPEP1503009EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Pep CodeENVPEP1503009EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI1503009EN
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys Deca

ETIM

ETIM 8EC000066
ETIM 10EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months
TeSys Deca Contactor 3P 65A 120V AC Coil, Compact 55mm Width
TeSys Deca Contactor 3P 65A 120V AC Coil, Compact 55mm Width
Loading video…

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$506.98/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!