Schneider Electric LC1D65ABD TeSys Deca 3P Contactor, 65A, 24V DC Coil, 55mm Width
- MPN: LC1D65ABD
- PPN: SCH-LC1D65ABD
CAD
$614.20
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Features
- Engineered with a highly efficient 24V DC standard coil, this TeSys D contactor integrates seamlessly into modern programmable logic controller (PLC) networks and low-voltage automation panels. This allows panel builders to maintain a safe, unified low-voltage control architecture, reducing control wiring complexity and ensuring fast, reliable switching for heavy industrial motor loads.
- Built for demanding industrial applications, this 3-pole contactor is strictly rated for 65 amps under AC-3 loads, safely managing three-phase electrical motors up to 40HP (at 480V). This rugged power switching capability ensures your conveyors, industrial pumps, and HVAC compressors operate continuously without experiencing dangerous contact welding, significantly extending the mechanical lifespan of your facility's critical equipment.
- Featuring Schneider Electric s patented EverLink creep-compensating terminals, this device maintains constant, dynamic pressure on bare cables to actively prevent the dangerous loosening caused by thermal cycling and heavy operational vibration. This fail-safe connection technology guarantees long-term electrical continuity, eliminating the frustrating need for routine maintenance retightening and drastically reducing the risk of catastrophic terminal fires.
- Ready to deploy straight out of the box, this industrial contactor features built-in 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for immediate status feedback and safety interlocking circuits. This highly efficient, space-saving footprint frees up valuable 35mm DIN-rail real estate in high-density electrical enclosures and lowers your total bill of materials by eliminating the need to source additional snap-on hardware.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, France, United States |
|---|
| Depth | 120 mm |
|---|
Complementary Attributes
| Maximum Horse Power Rating | 20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 1 phase motors20 hp at 200/208 V AC 50/60 Hz for 3 phase motors50 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
|---|---|
| Control Circuit Voltage Limits | 0.1...0.3 Uc (-40-70 °C):drop-out DC0.75...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC |
| Maximum Motor Phase Current | 65 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Control Circuit Type | DC standard |
|---|---|
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11000 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit |
| Electrical Durability | 0.5 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 65 A AC-3 <= 440 V, 1.45 Mcycles 65 A AC-3e <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms) |
| Mounting Support | plate, rail |
| Range | TeSys, TeSys Deca |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Certificate Agency | CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1 |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 1.3134800522102605, 1 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 5 kg CO2 eq., 4.622807401941327 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503009EN |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 1926 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Inrush Power In W | 19-19 W 20 °C) |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Total Lifecycle Carbon Footprint | 87 kg CO2 eq. |
| Connections Terminals | EverLink BTR screw connectors |
| Pep Code | ENVPEP1503009EN |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Low voltage; 2020; France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2020; France, FR |
| Recyclability Potential In % | 62 |
| Width Nominal | 55 mm |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
| Hold-in Power Consumption In W | 7.4-7.4 W 20 °C |
| Package Weight(Lbs) | 984.000 g |
| Warranty (In Months) | 18 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Contactor Application | motor control, resistive load |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 30 kW at 380/400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660/690 V AC 50/60 Hz (AC-3e), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3)30 kW at 380/400 V AC 50/60 Hz (AC-3)37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660/690 V AC 50/60 Hz (AC-3), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 9.6 W AC-16.3 W AC-3, 6.3 W AC-3e |
| Tightening Torque | control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2 |
| Control Circuit Voltage | 24 V |
| [Ie] Rated Operational Current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Connections - Terminals | control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endEverLink BTR screw connectorscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end |
| Carbon Footprint Of The Distribution Phase [A4] | 0.4333679304542079, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0.1 kg CO2 eq., 0.056449857336314566 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 80 kg CO2 eq., 80.1695225555932 |
| Local Publishable Date | 2026-06-27 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Contact Compatibility | M4 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Mechanical Durability | 10 Mcycles |
| Operating Time | 50 ±15 % ms closing16...24 ms opening |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Time Constant | 34 ms |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Inf Motor Phase Current | 65 A |
| Database Version | 2024-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 891.33 |
| Energy Model - Installation [A5] | No energy used |
| Energy Model - End Of Life [C1-c4] | Global, European and French datasets are used. |
| Height Nominal | 122 mm |
| [Icw] Rated Short-time Withstand Current | 640 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Uc] Control Circuit Voltage | 24 V24 V DC |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536490065 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503009EN |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1503009EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Reach Free Shvc | Yes |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 86.59562779753531 |
| Environmental Disclosure | ENVPEP1503009EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|


Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$614.20
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$614.20/ EA
Loading add to cart quantity...