Schneider Electric

Schneider Electric LC1D65ABD TeSys Deca 3P Contactor, 65A, 24V DC Coil, 55mm Width

  • MPN: LC1D65ABD
  • PPN: SCH-LC1D65ABD

CAD

$614.20

/ EA

Available to Order

Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3/3e (30kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Features

  • Engineered with a highly efficient 24V DC standard coil, this TeSys D contactor integrates seamlessly into modern programmable logic controller (PLC) networks and low-voltage automation panels. This allows panel builders to maintain a safe, unified low-voltage control architecture, reducing control wiring complexity and ensuring fast, reliable switching for heavy industrial motor loads.
  • Built for demanding industrial applications, this 3-pole contactor is strictly rated for 65 amps under AC-3 loads, safely managing three-phase electrical motors up to 40HP (at 480V). This rugged power switching capability ensures your conveyors, industrial pumps, and HVAC compressors operate continuously without experiencing dangerous contact welding, significantly extending the mechanical lifespan of your facility's critical equipment.
  • Featuring Schneider Electric s patented EverLink creep-compensating terminals, this device maintains constant, dynamic pressure on bare cables to actively prevent the dangerous loosening caused by thermal cycling and heavy operational vibration. This fail-safe connection technology guarantees long-term electrical continuity, eliminating the frustrating need for routine maintenance retightening and drastically reducing the risk of catastrophic terminal fires.
  • Ready to deploy straight out of the box, this industrial contactor features built-in 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for immediate status feedback and safety interlocking circuits. This highly efficient, space-saving footprint frees up valuable 35mm DIN-rail real estate in high-density electrical enclosures and lowers your total bill of materials by eliminating the need to source additional snap-on hardware.

Documentation & Downloads

Specifications

Key Specifications

Country of OriginBrazil, France, United States
Depth120 mm

Complementary Attributes

Maximum Horse Power Rating20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 1 phase motors20 hp at 200/208 V AC 50/60 Hz for 3 phase motors50 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Control Circuit Voltage Limits0.1...0.3 Uc (-40-70 °C):drop-out DC0.75...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC
Maximum Motor Phase Current65 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity1000 A at 440 V for power circuit conforming to IEC 60947
Control Circuit TypeDC standard
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11000 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability0.5 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 65 A AC-3 <= 440 V, 1.45 Mcycles 65 A AC-3e <= 440 V
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms)
Mounting Supportplate, rail
RangeTeSys, TeSys Deca
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
Certificate AgencyCCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]1.3134800522102605, 1 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]5 kg CO2 eq., 4.622807401941327
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1503009EN
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1926
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Inrush Power In W19-19 W 20 °C)
Number Of Poles3P
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Total Lifecycle Carbon Footprint87 kg CO2 eq.
Connections TerminalsEverLink BTR screw connectors
Pep CodeENVPEP1503009EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %62
Width Nominal55 mm
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In W7.4-7.4 W 20 °C
Package Weight(Lbs)984.000 g
Warranty (In Months)18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw30 kW at 380/400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660/690 V AC 50/60 Hz (AC-3e), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3)30 kW at 380/400 V AC 50/60 Hz (AC-3)37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660/690 V AC 50/60 Hz (AC-3), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4)
Power Dissipation Per Pole9.6 W AC-16.3 W AC-3, 6.3 W AC-3e
Tightening Torquecontrol circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm, control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m EverLink BTR screw connectors pozidriv No 2, power circuit 2.5 N.m EverLink BTR screw connectors pozidriv No 2
Control Circuit Voltage24 V
[Ie] Rated Operational Current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Connections - Terminalscontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endEverLink BTR screw connectorscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.4333679304542079, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.056449857336314566
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]80 kg CO2 eq., 80.1695225555932
Local Publishable Date2026-06-27
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Contact CompatibilityM4
Fire Resistance850 °C IEC 60695-2-1
Mechanical Durability10 Mcycles
Operating Time50 ±15 % ms closing16...24 ms opening
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Time Constant34 ms
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inf Motor Phase Current65 A
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh891.33
Energy Model - Installation [A5]No energy used
Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
Height Nominal122 mm
[Icw] Rated Short-time Withstand Current640 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Uc] Control Circuit Voltage24 V24 V DC
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI1503009EN
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach Free Of SvhcYes
Pep CodeENVPEP1503009EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint86.59562779753531
Environmental DisclosureENVPEP1503009EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys Deca

ETIM

ETIM 8EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period18 months