- Engineered with Schneider Electric s patented EverLink creep-compensating technology, this contactor maintains constant, relentless pressure on your bare power cables over time. This eliminates the dangerous and time-consuming need for routine retightening during scheduled panel maintenance, actively safeguarding your motor control center against thermal hotspots and electrical arcs caused by heavy industrial vibrations.
- Operating on a standard 24V DC coil, this TeSys Deca (TeSys D) contactor integrates seamlessly into contemporary industrial automation setups and programmable logic controller (PLC) networks. It provides highly reliable, precise switching for automated manufacturing lines and pump controls, keeping your critical processes running efficiently while minimizing the electrical noise often associated with AC coils.
- Strictly rated for 50 amps (AC-3) and capable of handling robust three-phase inductive loads up to 40 horsepower (at 480V), this 3-pole powerhouse is built for heavy-duty motor starting and stopping operations. It effortlessly manages the punishing high-inrush currents of commercial compressors, conveyors, and HVAC blowers, dramatically extending the mechanical lifespan of your equipment and minimizing costly facility downtime.
- Pre-equipped with one normally open (NO) and one normally closed (NC) auxiliary contact, this space-saving contactor is ready out-of-the-box for complex mechanical interlocking and remote status indication. This fully integrated design frees up valuable DIN-rail real estate inside dense electrical enclosures and significantly reduces your overall bill of materials (BOM) costs for commercial panel building and retrofits.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | France, United States |
|---|
| Depth | 120 mm |
|---|
Complementary Attributes
| Maximum Horse Power Rating | 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors3 hp at 115 V AC 50/60 Hz for 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
|---|---|
| Control Circuit Voltage Limits | 0.1...0.3 Uc (-40-70 °C):drop-out DC0.75...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC |
| Maximum Motor Phase Current | 50 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
| Control Circuit Type | DC standard |
|---|---|
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1900 A at 440 V for power circuit conforming to IEC 60947 |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit |
| Electrical Durability | 1.45 Mcycles 50 A AC-3 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 1.45 Mcycles 50 A AC-3e <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor closed 15 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms) |
| Mounting Support | plate, rail |
| Range | TeSys, TeSys Deca |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Certificate Agency | CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1 |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End-of-life Phase [C1 To C4] | 1.30645609471181, 1 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 5 kg CO2 eq., 4.598086506743781 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 1 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1503009EN |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 1926 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Inrush Power In W | 19-19 W 20 °C) |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Total Lifecycle Carbon Footprint | 87 kg CO2 eq. |
| Connections Terminals | EverLink BTR screw connectors |
| Pep Code | ENVPEP1503009EN |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Low voltage; 2020; France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2020; France, FR |
| Recyclability Potential In % | 62 |
| Width Nominal | 55 mm |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
| Hold-in Power Consumption In W | 7.4-7.4 W 20 °C |
| Package Weight(Lbs) | 999.000 g |
| Warranty (In Months) | 18 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Contactor Application | resistive load, motor control |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 22 kW at 380/400 V AC 50/60 Hz (AC-3e), 25 kW at 415 V AC 50/60 Hz (AC-3e), 30 kW at 440 V AC 50/60 Hz (AC-3e), 30 kW at 500 V AC 50/60 Hz (AC-3e), 33 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 220/230 V AC 50/60 Hz (AC-3)22 kW at 380/400 V AC 50/60 Hz (AC-3)25 kW at 415 V AC 50/60 Hz (AC-3)30 kW at 440 V AC 50/60 Hz (AC-3), 30 kW at 500 V AC 50/60 Hz (AC-3)33 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 3.7 W AC-39.6 W AC-1, 3.7 W AC-3e |
| Tightening Torque | control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2 |
| Control Circuit Voltage | 24 V |
| [Ie] Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Connections - Terminals | control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-25 mm² - cable stiffness: solid without cable endEverLink BTR screw connectorscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-35 mm² - cable stiffness: flexible without cable end |
| Carbon Footprint Of The Distribution Phase [A4] | 0.43105045489028165, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase [A5] | 0.1 kg CO2 eq., 0.05614798644146796 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 80 kg CO2 eq., 80.1695225555932 |
| Local Publishable Date | 2026-06-27 |
| Stocking Flag | Y |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Contact Compatibility | M4 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Mechanical Durability | 10 Mcycles |
| Operating Time | 50 ±15 % ms closing16...24 ms opening |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Time Constant | 34 ms |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Inf Motor Phase Current | 50 A |
| Database Version | 2024-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 891.33 |
| Energy Model - Installation [A5] | No energy used |
| Energy Model - End Of Life [C1-c4] | Global, European and French datasets are used. |
| Height Nominal | 122 mm |
| [Icw] Rated Short-time Withstand Current | 400 A 40 °C - 10 s for power circuit810 A 40 °C - 1 s for power circuit84 A 40 °C - 10 min for power circuit208 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Uc] Control Circuit Voltage | 24 V24 V DC |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536410045 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1503009EN |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1503009EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Reach Free Shvc | Yes |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 86.56126359838053 |
| Environmental Disclosure | ENVPEP1503009EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|


Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$533.46
/ EA
Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$533.46/ EA
Loading add to cart quantity...