TeSys Deca Reversing Contactor, 3P, 40A, 24-60V AC/DC Coil, Compact Design
Schneider Electric

Schneider Electric LC2D40ABNE TeSys Deca Reversing Contactor, 3P, 40A, 24-60V AC/DC Coil, Compact Design

  • MPN: LC2D40ABNE
  • PPN: SCH-LC2D40ABNE

CAD

$1122.48

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys Deca Reversing Contactor, 3P, 40A, 24-60V AC/DC Coil, Compact Design

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Sweden
Depth120 mm

Physical Attributes

Color
Gray SE GREY 6), Green SE GREEN 2)

Complementary Attributes

Control Circuit Type
AC 50/60 Hz AC/DC electronic, DC AC/DC electronic, AC 50/60 Hz AC/DC electronicDC AC/DC electronic
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 800 A at 440 V for power circuit conforming to IEC 60947
Maximum Motor Phase Current
40 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
800 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC, 0.8...1.1 Uc (-40-60 °C):operational DC, 1...1.1 Uc (60-70 °C):operational AC/DC
Maximum Horse Power Rating10 hp at 230/240 V AC 60 Hz for 3 phase motors3 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 200/208 V AC 60 Hz for 3 phase motors, 30 hp at 460/480 V AC 60 Hz for 3 phase motors, 30 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Operating Rate3600 cyc/h 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit
Insulation Resistance
> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw
11 kW at 220...230 V AC 50 Hz, 18.5 kW at 380...400 V AC 50 Hz, 22 kW at 415 V AC 50 Hz, 22 kW at 440 V AC 50 Hz, 22 kW at 500 V AC 50 Hz, 30 kW at 660...690 V AC 50 Hz
Power Dissipation Per Pole
2.4 W AC-3, 5.4 W AC-1, 2.4 W AC-3e
Tightening Torque
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm, power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
[Icw] Rated Short-time Withstand Current
100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 320 A 40 °C - 10 s for power circuit, 720 A 40 °C - 1 s for power circuit, 72 A 40 °C - 10 min for power circuit, 165 A 40 °C - 1 min for power circuit
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit, 60 A (at 60 °C) for power circuit
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Non-overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]
3.2111256134685835, 3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
15 kg CO2 eq., 14.707659819861778
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1607010
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
1929
China Rohs In Scope
No
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Coil Technology
built-in bidirectional peak limiting
Device Short Name
LC2D
Interlocking Type
mechanical
Overvoltage Category
III
Product Availability
Stock - Normally stocked in distribution facility
Product Or Component Type
reversing contactor
Range Of Product
TeSys Deca Advanced
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inf Motor Phase Current
40 A
Database Version
2024-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unit
unit
Energy Consumption On Product Lifetime, In Kwh
455.52
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
122 mm
[Ue] Rated Operational Voltage
power circuit 690 V AC 25...400 Hz
Rated Thermal Current (Ith)
60 A
Nbr. Of Units In Pkg.
1
Take-back
No
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Mechanical Robustnessvibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
Mounting Supportrail, plate
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation CategoryAC-3, AC-1, AC-3e
[Ie] Rated Operational Current60 A (at <60 °C) at <= 440 V AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] Control Circuit Voltage24...60 V, 24...60 V AC 50/60 Hz, 24...60 V DC
Connections - Terminalscontrol circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible without cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²solidcontrol circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.22194339884224623, 0.2 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.14396868592458148
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]41 kg CO2 eq., 40.97115649032773
Local Publishable Date2025-12-10
Stocking FlagN
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Compatibility CodeLC2D
Fire Resistance850 °C IEC 60695-2-1
Number Of Poles3P
Pole Contact Composition3 NO
Product NameTeSys Deca Advanced
Protective TreatmentTH IEC 60068-2-30
ReturnabilityYes
Software Versionv6.2.4
Total Lifecycle Carbon Footprint59 kg CO2 eq.
Control Circuit Voltage24...60 V
Pep CodeENVPEP1607010EN
Pep Verification Date2025-07-25
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime, In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential, In %64
Width Nominal119 mm
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Halogen-free StatusHalogen free plastic parts and cables product
Package Weight(Lbs)2.229 kg
Warranty (In Months)18

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage
-60-80 °C, -60-80 °C
Take Back
No
Recycled Metal Content At Cr Level
0 %
Carbon Footprint
59.25585400842492
Environmental Disclosure
ENVPEP1607010EN
Halogen Content Performance
Halogen free plastic parts & cables product
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Pep Code
ENVPEP1607010EN
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Ambient Air Temperature For Operation-40-60 °C-40-60 °C, 60-70 °C with derating
Climatic WithstandIACS E10, IEC 60947-1 Annex Q category D
Halogene PerformanceHalogen free plastic parts & cables product
Mercury FreeYes
Circularity ProfileENVEOLI1607010
Eu Rohs DirectiveCompliant By Exemption
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2025-07-25
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Type
reversing contactor
Range Of ProductTeSys Deca Advanced

ETIM

ETIM 8
EC000010
ETIM 9EC000010

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Overview Attributes

Device Presentation
preassembled with reversing power busbar

Similar Products

Loading carousel layout...

CAD$1122.48/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])