Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France, Indonesia, Singapore
Complementary Attributes
- Control Circuit Type
- AC 50/60 Hz, AC 50/60 Hz
- Maximum Horse Power Rating
- 5 hp at 230/240 V AC 60 Hz for 3 phase motors1 hp at 115 V AC 60 Hz for 1 phase motors3 hp at 230/240 V AC 60 Hz for 1 phase motors, 5 hp at 200/208 V AC 60 Hz for 3 phase motors10 hp at 460/480 V AC 60 Hz for 3 phase motors15 hp at 575/600 V AC 60 Hz for 3 phase motors
- Maximum Motor Phase Current
- 18 A
- Minimum Switching Current
- 5 mA for signalling circuit
- Rated Breaking Capacity
- 300 A at 440 V for power circuit conforming to IEC 60947
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Contactor Application
- motor control, resistive load
- Inrush Power In Va
- 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
- Mechanical Robustness
- vibrations contactor open2 Gn, 5...300 Hzvibrations contactor closed4 Gn, 5...300 Hzshocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
- Mounting Support
- plate, rail
- Power Range
- 4-6 kW 200-240 V 3 phase7-11 kW 380-440 V 3 phase, 7-11 kW 480-500 V 3 phase
- Range
- TeSys, TeSys Deca
- Tightening Torque
- control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
- Control Circuit Voltage
- 48 V
- [Ie] Rated Operational Current
- 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
- [Ui] Rated Insulation Voltage
- signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
- Non-overlap Time
- 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
- Carbon Footprint Of The Installation Phase [A5]
- 0.1 kg CO2 eq., 0.11547926448314888
- Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
- 49 kg CO2 eq., 48.85022504616
- Local Publishable Date
- 2026-06-27
- Stocking Flag
- N
- Device Type
- LV equipment - LV contactor
- Traceability
- No
- Average Life Duration
- 20 year(s)
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Free of Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Free of Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant
- Rohs Eur Full Compliance Status
- Compliant
- China Rohs Label
- 1
- Without Single Use Plastic
- Yes
- Tier Id
- 1
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Average Impedance
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- Compatibility Code
- LC2D
- Contactor Coil Voltage
- 48 V AC standard
- Fire Resistance
- 850 °C IEC 60695-2-1
- Heat Dissipation
- 2-3 W 50/60 Hz
- Mechanical Durability
- 15 Mcycles
- Number Of Poles
- 3P
- Overvoltage Category
- III
- Product Availability
- Stock - Normally stocked in distribution facility
- Protective Treatment
- TH IEC 60068-2-30
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Software Version
- v6.2.4
- Total Lifecycle Carbon Footprint
- 52 kg CO2 eq.
- Inf Motor Phase Current
- 18 A
- Database Version
- 2024-01
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime In Kwh
- 543.12
- Energy Model - Installation [A5]
- No energy used
- Energy Model - End Of Life [C1-c4]
- Global, European and French datasets are used.
- Height Nominal
- 77 mm
- [Icw] Rated Short-time Withstand Current
- 40 A 40 °C - 10 min for power circuit84 A 40 °C - 1 min for power circuit145 A 40 °C - 10 s for power circuit240 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
- [Ue] Rated Operational Voltage
- power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
- Hold-in Power Consumption In Va
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
- Nbr. Of Units In Pkg.
- 1
- Take-back
- No
- Customs Code
- 8536490065
Environment Attributes Main
- China Rohs Regulation
- Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
- Climatic Withstand
- IACS E10, IEC 60947-1 Annex Q category D
- Reach Free Shvc
- Yes
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 52.22536999998361
- Circularity Profile
- ENVEOLI1501004
- Eu Rohs Directive
- Compliant
- Operating Altitude
- 0...9842.52 ft (0...3000 m)
- Packaging Without Single Use Plastic
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Pep Verification Date
- 2026-03-17
- Psr Version
- PSR-0005-ed3-2023 06 06
General Attributes
- Range Of Product
- TeSys D, TeSys Deca
ETIM
- ETIM 8
- EC000010
Contractual Warranty Attributes
- Warranty Period
- 18 months
Overview Attributes
- Device Presentation
- preassembled with reversing power busbar
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$602.57
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$602.57/ EA
Loading add to cart quantity...