TeSys Deca Contactor, 3P, 12A, 24V AC, Bulk Pack of 10
Schneider Electric

Schneider Electric LC1D12B7TQ TeSys Deca Contactor, 3P, 12A, 24V AC, Bulk Pack of 10

  • MPN: LC1D12B7TQ
  • PPN: SCH-LC1D12B7TQ

CAD

$207.97

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys D contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (4kW@400V). It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Pack of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Documentation & Downloads

Specifications

Key Specifications

[Uc] Control Circuit Voltage
24 V AC 50/60 Hz
Range Of Product
TeSys Deca
Product Or Component Type
contactor
Utilisation Category
AC-3 || AC-1 || AC-3e
Poles Description
3P
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz
Contactor Applicationresistive load || motor control
RangeTeSys || TeSys Deca
[Ie] Rated Operational Current25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Device Short NameLC1D

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Power Dissipation Per Pole
0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e
Auxiliary Contact Composition
1 NO + 1 NC
Control Circuit Voltage Limits
0.3...0.6 Uc 60-60 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc 60-60 °C operational AC 50 Hz || 0.85...1.1 Uc 60-60 °C operational AC 60 Hz
Control Circuit Type
AC 50/60 Hz
Insulation Resistance
> 10 MOhm for control circuit
Irms Rated Making Capacity
140 A AC for control circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
Inrush Power In Va
70-70 VA cos phi 0.75 (at 20 °C)
Pole Contact Composition
3 NO
Coil Technology
without built-in bidirectional peak limiting diode suppressor
Minimum Switching Voltage
17 V for control circuit
Tightening Torque
control circuit 1.7 N.m flat Ø 6 mm || control circuit 1.7 N.m Philips No 2 || power circuit 1.7 N.m flat Ø 6 mm || power circuit 1.7 N.m Philips No 2 || control circuit 1.7 N.m pozidriv No 2 || power circuit 1.7 N.m pozidriv No 2
Compatibility Code
LC1D
Overvoltage Category
III
Motor Power Kw
7.5 kW at 500 V AC 50/60 Hz || 7.5 kW at 660...690 V AC 50/60 Hz || 5.5 kW at 380...400 V AC 50/60 Hz || 5.5 kW at 415...440 V AC 50/60 Hz || 3 kW at 220...230 V AC 50/60 Hz
Heat Dissipation
2-3 W at 50/60 Hz for control circuit
Minimum Switching Current5 mA for control circuit
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for control circuit || 25 A (at 60 °C) for power circuit
Mounting Supportplate || rail
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity250 kA at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating10 A gG for control circuit conforming to IEC 60947-5-1 || 25 A at <= 690 V coordination type 2 for power circuit || 40 A at <= 690 V coordination type 1 for power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Connections - Terminalscontrol circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminal 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminal 2 1-2.5 mm² - cable stiffness: flexible with cable end
Operating Time4...19 ms opening || 12...22 ms closing
Maximum Operating Rate3600 cyc/h 60 °C
Mechanical Durability15000000 cycles
Hold-In Power Consumption In Va7-7 VA 50/60 Hz cos phi 0.3 (at 20 °C)
Motor Power Hp1 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA || 1 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL || 10 hp at 575/600 V AC 60 Hz for 3 phases motors conforming to CSA || 10 hp at 575/600 V AC 60 Hz for 3 phases motors conforming to UL || 2 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA || 2 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL || 3 hp at 200/208 V AC 60 Hz for 3 phases motors conforming to CSA || 3 hp at 200/208 V AC 60 Hz for 3 phases motors conforming to UL || 3 hp at 230/240 V AC 60 Hz for 3 phases motors conforming to CSA || 3 hp at 230/240 V AC 60 Hz for 3 phases motors conforming to UL || 7.5 hp at 460/480 V AC 60 Hz for 3 phases motors conforming to CSA || 7.5 hp at 460/480 V AC 60 Hz for 3 phases motors conforming to UL
[Ui] Rated Insulation Voltagecontrol circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-4-1 || power circuit 690 V IEC 60947-4-1
Protective Coverwith

Environment

Product Certifications
UL || CCC || GL || DNV || LROS (Lloyds register of shipping) || RINA || GOST || BV || CSA || UKCA
Standards
EN/IEC 60947-5-1 || UL 508 || CSA C22.2 No 14 || EN/IEC 60947-4-1 || IEC 60335-1
Net Weight
3.25 kg
Ip Degree Of Protection
IP2X IEC 60529 || IP2X VDE 0106
Operating Altitude
3000 m without derating
Fire Resistance
850 °C IEC 60695-2-1
Depth
86 mm
Height77 mm
Climatic WithstandIACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame RetardanceV1 UL 94
Mechanical Robustnessshocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Quantity Per Setset of 10
Width45 mm
Permissible Ambient Air Temperature Around The Device-5-60 °C || -40-70 °C at Uc

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1501004
Pvc Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity Profile
ENVEOLI1501004
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach Free Of SvhcYes
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs DirectiveCompliant

Accessories