Schneider Electric LC1D115ALSE Contactor, Tesys Deca Advanced, 3P(3NO), 75hp at 480V, 115A, 200-500V AC/DC coil, Everlink
- MPN: LC1D115ALSE
- PPN: SCH-LC1D115ALSE
- UNSPSC: 39121529
CAD
$318.40
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Features
- Efficient solution combining robustness with ease of use, ensuring customers experience reliability without complexity
- Electronic wide-band coil withstands voltage fluctuations allows quick coil operating frequency and ensures long uptime
- Sustainability is advanced with 50% coil inrush savings.
- Fewer references covering wider applications means simpler to select and less inventory to carry
- Compact size with robust EverLink power connection improves operational efficiency and eliminates future maintenance
- Unique QR code supports quick access to product data, anti-counterfeit checking and digital assets
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | China |
|---|---|
| Depth | 155 mm |
| Weight | 2661.5 g |
|---|
Complementary Attributes
| Control Circuit Type | AC 50/60 Hz, DC, AC 50/60 Hz, DC |
|---|---|
| Uc Control Circuit Voltage | 200...500 V, 200...500 V AC 50/60 Hz, 200...500 V DC |
| Control Circuit Voltage Limits | 0.8 Uc Min...1.1 Uc Max (-40-60 °C):operational AC/DC0.1 Uc Max (-40-60 °C):drop-out AC/DC |
| Maximum Horse Power Rating | 30 hp at 200/208 V 60 Hz40 hp at 230/240 V 60 Hz75 hp at 460/480 V 60 Hz100 hp at 575/600 V 60 Hz |
| Maximum Operating Rate | 2400 cyc/h at 60 °C3600 cyc/h at Uc at 20 ºC |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Icw Rated Short Time Withstand Current | 350 A 40 °C - 10 min for power circuit600 A 40 °C - 1 min for power circuit1280 A 40 °C - 10 s for power circuit1800 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| Uimp Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
| Ie Rated Operational Current | 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
|---|---|
| Ui Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1 |
| Irms Rated Making Capacity | 1560 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Maximum Motor Phase Current | 115 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| Ue Rated Operational Voltage | power circuit <= 1000 V AC 16.67...400 Hzpower circuit <= 300 V DC |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Contactor Application | motor control, resistive load |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 55 kW at 400 V AC 50/60 Hz (AC-3e), 59 kW at 415 V AC 50/60 Hz (AC-3e), 59 kW at 440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e)55 kW at 400 V AC 50/60 Hz (AC-4), 55 kW at 440 V AC 50/60 Hz (AC-4)65 kW at 690 V AC 50/60 Hz (AC-4), 30 kW at 230 V AC 50/60 Hz (AC-3)55 kW at 400 V AC 50/60 Hz (AC-3)59 kW at 415 V AC 50/60 Hz (AC-3), 59 kW at 440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 230 V AC 50/60 Hz (AC-3e), 30 kW at 230 V AC 50/60 Hz (AC-4), 63 kW at 500 V AC 50/60 Hz (AC-4), 50 kW at 1000 V AC 50/60 Hz (AC-4) |
| Tightening Torque | power circuit 12 N.m connector hexagonal 4 mmcontrol circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2 |
| Connections Terminals | power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable endpower circuit: connector 2 10-50 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, EverLink BTR screw connectors |
| Certificate Agency | CB Scheme, CCC, cULus, CE, UKCA, EU-RO-MR by DNV-GL |
| Carbon Footprint Of The Distribution Phase A4 | 0.40266917880651387, 0.4 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0.3 kg CO2 eq., 0.29247387156553895 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 305 kg CO2 eq., 305.18684947927113 |
| Local Publishable Date | 2026-07-01 |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Reference contains Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Reference contains Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant By Exemption |
| Rohs Eur Full Compliance Status | Compliant By Exemption |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Associated Fuse Rating | 125 A aM at <= 440 V for power circuit100 A aM at <= 690 V for power circuit200 A gG at <= 690 V for power circuit10 A gG for signalling circuit0.5 A gG for control circuit |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Device Short Name | LC1D |
| Heat Dissipation | 3-3 W at 20 °C |
| Inrush Power In W | 120-120 W 20 °C) |
| Mounting Support | plate |
| Operating Time | 10...80 ms opening20...90 ms closing |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range | TeSys Deca |
| Returnability | Yes |
| Signalling Circuit Frequency | 16.67...400 Hz |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Database Version | 2023-02 |
| Height Nominal | 152 mm |
| Nbr. Of Units In Pkg. | 1 |
| Ith Conventional Free Air Thermal Current | 200 A (at 60 °C) for power circuit |
| Hold In Power Consumption In W | 5.1-5.1 W 20 °C |
| Warranty In Months | 18 |
| Functional Unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Recyclability Potential In % | 78 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Electrical Durability | 1 Mcycles 115 A AC-3 <= 440 V, 1 Mcycles 115 A AC-3e <= 440 V, 0.5 Mcycles 200 A AC-1 <= 440 V |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz) IEC 60068-2-6vibrations contactor closed 4 Gn, 5...300 Hz) IEC 60068-2-6, shocks contactor open 10 Gn for 11 ms) IEC 60068-2-27, shocks contactor closed 15 Gn for 11 ms) IEC 60068-2-27 |
| Power Dissipation Per Pole | 6 W AC-3, 6 W AC-3e22 W AC-1 |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4, DC-1, DC-3, DC-5 |
| Control Circuit Voltage | 200...500 V |
| Non Overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 5.495932923081058, 5 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 26 kg CO2 eq., 26.07504370221946 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Serviceability | No |
| Field Service Division | PPIBS |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI2408027 |
| Reach Full Compliance Status Id | CONTAINS_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2538 |
| China Rohs In Scope | No |
| Without Single Use Plastic | No |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Average Impedance | 0.45 mOhm - Ith 200 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Fire Resistance | 850 °C IEC 60695-2-11 |
| Inrush Power In Va | 170-170 VA (at 20 °C) |
| Mechanical Durability | 8 Mcycles |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | noneIEC 60068-2-30 |
| Range Of Product | TeSys Deca Advanced |
| Safety Reliability Level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.1 |
| Total Lifecycle Carbon Footprint | 337 kg CO2 eq. |
| Inf Motor Phase Current | 115 A |
| Data Source | extrapolated product |
| Width Nominal | 97 mm |
| Customs Code | 8536490065 |
| Hold In Power Consumption In Va | 16.5-16.5 VA (at 20 °C) |
| Halogen Free Status | Halogen free plastic parts product |
| Functional Unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 yearsEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts 3O, a rated voltage up to 1000V, a rated current AC3 115A, a control circuit voltage 100-250VAC/DC, with 3 poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional Unit Unit | unit |
| Energy Consumption On Product Lifetime In Kwh | 744.6 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information. |
|---|---|
| Permissible Ambient Air Temperature Around The Device | -40-60 °C operation, -40-60 °C operation, -60-80 °C storage, -60-80 °C storage-40-60 °C operation, -40-60 °C operation60-70 °C with derating, -60-80 °C storage, -60-80 °C storage |
| Halogene Performance | Halogen free plastic parts product |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI2408027 |
| Eu Rohs Directive | Compliant By Exemption |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
| Pep Verification Date | 2025-08-12 |
| Psr Version | PSR-0005-ed3.1-EN-2023 12 08 |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Carbon Footprint | 337.4529691549437 |
| Environmental Disclosure | ENVPEP2408027EN |
| Halogen Content Performance | Halogen free plastic parts product |
| Operating Altitude | 0...9842.52 ft (0...3000 m) without derating |
| Packaging Without Single Use Plastic | No |
| Pep Code | ENVPEP2408027EN |
| Pcr Version | PCR-4-ed4-EN-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca Advanced |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|---|
| ETIM 10 | EC000066 |
| ETIM 9 | EC000066 |
|---|

Accessories
Loading carousel layout...
Loading carousel layout...
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$318.40
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Loading add to cart quantity...