TeSys Deca Advanced contactor, 3 poles (3NO) for motor control applications up to 75hp at 480V, 160A general purpose It is equipped with a 200-500V AC/DC wide-band electronic coil that has lower power consumption, along with integrated 1NO+1NC auxiliary contacts. It can be installed in any orientation, and LRD43 could be directly mounted below contactor. The operating temperature range is between -40°C and 70°C, and it can be installed at altitudes of up to 3000m without derating. It is designed for demanding applications with improved performance under harsh environment including salt-mist, dust and high shock. The dimension is 152mm x 97mm x 155mm (H x W x D). Compact size enables panel space savings. Simple wiring with all front access to control circuit enhances accessibility and safety.

Features

  • Efficient solution combining robustness with ease of use, ensuring customers experience reliability without complexity
  • Electronic wide-band coil withstands voltage fluctuations allows quick coil operating frequency and ensures long uptime
  • Sustainability is advanced with 50% coil inrush savings.
  • Fewer references covering wider applications means simpler to select and less inventory to carry
  • Compact size with robust EverLink power connection improves operational efficiency and eliminates future maintenance
  • Unique QR code supports quick access to product data, anti-counterfeit checking and digital assets

Documentation & Downloads

Specifications

Key Specifications

Country of OriginChina
Depth155 mm
Weight2661.5 g

Complementary Attributes

Control Circuit TypeAC 50/60 Hz, DC, AC 50/60 Hz, DC
Uc Control Circuit Voltage200...500 V, 200...500 V AC 50/60 Hz, 200...500 V DC
Control Circuit Voltage Limits0.8 Uc Min...1.1 Uc Max (-40-60 °C):operational AC/DC0.1 Uc Max (-40-60 °C):drop-out AC/DC
Maximum Horse Power Rating30 hp at 200/208 V 60 Hz40 hp at 230/240 V 60 Hz75 hp at 460/480 V 60 Hz100 hp at 575/600 V 60 Hz
Maximum Operating Rate2400 cyc/h at 60 °C3600 cyc/h at Uc at 20 ºC
Minimum Switching Voltage17 V for signalling circuit
Icw Rated Short Time Withstand Current350 A 40 °C - 10 min for power circuit600 A 40 °C - 1 min for power circuit1280 A 40 °C - 10 s for power circuit1800 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Uimp Rated Impulse Withstand Voltage8 kV IEC 60947
Ie Rated Operational Current115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Ui Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Irms Rated Making Capacity1560 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Motor Phase Current115 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947
Ue Rated Operational Voltagepower circuit <= 1000 V AC 16.67...400 Hzpower circuit <= 300 V DC

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Contactor Applicationmotor control, resistive load
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw55 kW at 400 V AC 50/60 Hz (AC-3e), 59 kW at 415 V AC 50/60 Hz (AC-3e), 59 kW at 440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e)55 kW at 400 V AC 50/60 Hz (AC-4), 55 kW at 440 V AC 50/60 Hz (AC-4)65 kW at 690 V AC 50/60 Hz (AC-4), 30 kW at 230 V AC 50/60 Hz (AC-3)55 kW at 400 V AC 50/60 Hz (AC-3)59 kW at 415 V AC 50/60 Hz (AC-3), 59 kW at 440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 230 V AC 50/60 Hz (AC-3e), 30 kW at 230 V AC 50/60 Hz (AC-4), 63 kW at 500 V AC 50/60 Hz (AC-4), 50 kW at 1000 V AC 50/60 Hz (AC-4)
Tightening Torquepower circuit 12 N.m connector hexagonal 4 mmcontrol circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Connections Terminalspower circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable endpower circuit: connector 2 10-50 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, EverLink BTR screw connectors
Certificate AgencyCB Scheme, CCC, cULus, CE, UKCA, EU-RO-MR by DNV-GL
Carbon Footprint Of The Distribution Phase A40.40266917880651387, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50.3 kg CO2 eq., 0.29247387156553895
Carbon Footprint Of The Use Phase B2 B3 B4 B6305 kg CO2 eq., 305.18684947927113
Local Publishable Date2026-07-01
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating125 A aM at <= 440 V for power circuit100 A aM at <= 690 V for power circuit200 A gG at <= 690 V for power circuit10 A gG for signalling circuit0.5 A gG for control circuit
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Device Short NameLC1D
Heat Dissipation3-3 W at 20 °C
Inrush Power In W120-120 W 20 °C)
Mounting Supportplate
Operating Time10...80 ms opening20...90 ms closing
Pole Contact Composition3 NO
Product Or Component Typecontactor
RangeTeSys Deca
ReturnabilityYes
Signalling Circuit Frequency16.67...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Database Version2023-02
Height Nominal152 mm
Nbr. Of Units In Pkg.1
Ith Conventional Free Air Thermal Current200 A (at 60 °C) for power circuit
Hold In Power Consumption In W5.1-5.1 W 20 °C
Warranty In Months18
Functional Unit Quantity1
Reference Lifetime In Y20
Recyclability Potential In %78
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability1 Mcycles 115 A AC-3 <= 440 V, 1 Mcycles 115 A AC-3e <= 440 V, 0.5 Mcycles 200 A AC-1 <= 440 V
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz) IEC 60068-2-6vibrations contactor closed 4 Gn, 5...300 Hz) IEC 60068-2-6, shocks contactor open 10 Gn for 11 ms) IEC 60068-2-27, shocks contactor closed 15 Gn for 11 ms) IEC 60068-2-27
Power Dissipation Per Pole6 W AC-3, 6 W AC-3e22 W AC-1
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4, DC-1, DC-3, DC-5
Control Circuit Voltage200...500 V
Non Overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End Of Life Phase C1 To C45.495932923081058, 5 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A326 kg CO2 eq., 26.07504370221946
Local Data StatusPublishable
Return IndicatorY
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI2408027
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2538
China Rohs In ScopeNo
Without Single Use PlasticNo
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Average Impedance0.45 mOhm - Ith 200 A 50 Hz for power circuit
Compatibility CodeLC1D
Fire Resistance850 °C IEC 60695-2-11
Inrush Power In Va170-170 VA (at 20 °C)
Mechanical Durability8 Mcycles
Number Of Poles3P
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentnoneIEC 60068-2-30
Range Of ProductTeSys Deca Advanced
Safety Reliability LevelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.1
Total Lifecycle Carbon Footprint337 kg CO2 eq.
Inf Motor Phase Current115 A
Data Sourceextrapolated product
Width Nominal97 mm
Customs Code8536490065
Hold In Power Consumption In Va16.5-16.5 VA (at 20 °C)
Halogen Free StatusHalogen free plastic parts product
Functional Unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 yearsEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts 3O, a rated voltage up to 1000V, a rated current AC3 115A, a control circuit voltage 100-250VAC/DC, with 3 poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional Unit Unitunit
Energy Consumption On Product Lifetime In Kwh744.6

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Permissible Ambient Air Temperature Around The Device-40-60 °C operation, -40-60 °C operation, -60-80 °C storage, -60-80 °C storage-40-60 °C operation, -40-60 °C operation60-70 °C with derating, -60-80 °C storage, -60-80 °C storage
Halogene PerformanceHalogen free plastic parts product
Mercury FreeYes
Circularity ProfileENVEOLI2408027
Eu Rohs DirectiveCompliant By Exemption
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2025-08-12
Psr VersionPSR-0005-ed3.1-EN-2023 12 08
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Take BackNo
Recycled Metal Content At Cr Level0 %
Carbon Footprint337.4529691549437
Environmental DisclosureENVPEP2408027EN
Halogen Content PerformanceHalogen free plastic parts product
Operating Altitude0...9842.52 ft (0...3000 m) without derating
Packaging Without Single Use PlasticNo
Pep CodeENVPEP2408027EN
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys Deca Advanced

ETIM

ETIM 8EC000066
ETIM 10EC000066
ETIM 9EC000066
Contactor, Tesys Deca Advanced, 3P(3NO), 75hp at 480V, 115A, 200-500V AC/DC coil, Everlink
Loading video…

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$318.40/EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!