Description
Perfectly suited for buildings and industry, utilities, and large industrial processes. This relay is configurable to Feeder and Motor Protection applications. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 24 VDC to 48 VDC network. It include 16 digital inputs, 8 digital outputs, 2 LC communication port and 1 USB on front of the device. Mechanical dimensions are 169.5 mm in height, 170 mm in width and 205 mm in depth. The relays are certified with EN 60255-26 for electromagnetic compatiblity. The device is compatible with aditional modules and accessories: connection cables, communication modules, temperature and analogue input and output modules, and other accessories. This device has pluggable ring-lug terminals for current inputs.
Features
- Perfectly suited for buildings and industry, utilities, and large industrial processes.
- Simple, reliable, safe and easy-to-use, thanks to the User Interface display
- The protection relay can to be supplied by a 24 VDC to 48 VDC network
- It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others
- This relay is configurable to Feeder and Motor Protection applications.
Specifications
Communications & Management Attributes
- Communication Port Protocol
- IEC 61850 ed. 1, IEC 61850 ed. 2, IEC 60870-5-101, DNP3 TCP, Modbus TCP, EtherNet/IP
Redundancy Communication Port ProtocolRSTP, PRP
Physical Attributes
- Mounting Case Size
- 30TE
Complementary Attributes
- Integrated Connection Type
- front USB port 1, rear LC 2
Important Information Attributes
- Control Type
- switchgear control and monitoring, programmable switchgear interlocking, local control on single-line diagram, local control with I/O keys, local/remote control, 2 function keys, mobile application with Easergy SmartApp, web-server, programmable logic
- Electromagnetic Compatibility
- emission tests IEC/EN 60255-26 ed. 3, emission tests CISPR 11, emission tests CISPR 22, EMC immunity IEC/EN 60255-26 ed. 3, EMC immunity EN/IEC 61000-4-18, EMC immunity level 4 EN/IEC 61000-4-2, EMC immunity level 3 EN/IEC 61000-4-3, EMC immunity level 4 EN/IEC 61000-4-4, EMC immunity level 3 EN/IEC 61000-4-5, EMC immunity level 3 EN/IEC 61000-4-6, EMC immunity EN/IEC 61000-4-8, EMC immunity level 5 EN/IEC 61000-4-9, EMC immunity EN/IEC 61000-4-29, EMC immunity EN/IEC 61000-4-11, EMC immunity EN/IEC 61000-4-17
- Local Signalling
- 4 LEDs, 8 LEDs programmable
- Protection Type
- phase overcurrent 50/51, directional phase overcurrent 67, earth fault overcurrent 50N/51N, directional earth fault 67N, transient earth fault 67NI, capacitor bank unbalance 51C 8-8, broken conductor 46 I2/I1, cold load pick-up 67NI, H2 detection 68H2, H5 detection 68H5, breaker failure 50BF, switch ON to fault (SOTF) 68H5, directional active underpower 37P, fault locator 21FL, recloser 79, phase undercurrent 37, excessive starting time, locked rotor 48/51LR, motor restart inhibition 66, switch ON to fault (SOTF) 27P, capacitor overvoltage 59C, negative sequence overcurrent 46, overvoltage 59, undervoltage 27, positive sequence undervoltage 27P, earth fault overvoltage 59N, underfrequency 81/81N, rate of change of frequency 81R, synchro-check 25, lockout relay 86, CT supervision 60, VT supervision 60, programmable stages 99 8-8, programmable curve 99 8-8
- Type Of Measurement
- voltage zero sequence, voltage positive sequence, voltage negative sequence, voltage ratio of negative and positive, RMS active power ratio of negative and positive, reactive power phase to earth, current phasor diagram view, current 2nd, 15th harmonics with THD, RMS reactive power zero sequence, voltage 2nd, 15th harmonics with THD, apparent power positive sequence, RMS apparent power negative sequence, active energy ratio of negative and positive, condition monitoring CB wear phasor diagram view, voltage interruption 2nd, 15th harmonics with THD, current 3-phase, current zero sequence, current positive sequence, current negative sequence, current ratio of negative and positive, voltage phase to earth, voltage phase to phase, short circuit fault reactance 2nd, 15th harmonics with THD, fault location current phase to phase, earth fault reactance positive sequence, frequency negative sequence, active power, RMS active power, reactive power, RMS reactive power ratio of negative and positive, apparent power, RMS apparent power, active energy, reactive energy phase to earth, cos φ, tan φ, power angle, power factor, voltage phasor diagram view, condition monitoring CB wear, voltage interruption phasor diagram view
- Carbon Footprint Of The End Of Life Phase C1 To C4
- 8 kg CO2 eq., 7.82537379006275
- Carbon Footprint Of The Manufacturing Phase A1 To A3
- 95 kg CO2 eq., 94.8654267903303
- Connections Terminals
- screw removable (digital input/output), pin removable (voltage transformer), pin removable (current transformer)
- Network And Machine Diagnosis Type
- event recording, disturbance recording, tripping context
- Switchgear Diagnosis Type
- CT supervision TCS, trip circuit supervision TCS
- Local Data Status
- Publishable
- Device Type
- Relay, Control & Measurement - Protection relay
- Traceability
- Yes
- Average Life Duration
- 15 year(s)
- Scope Perimeter
- At least in Europe
- End Of Life Doc Ref
- ENVEOLI1706006_V2
- Reach Full Compliance Status Id
- CONTAINS_SVHC
- ROHS EUR In Scope
- Yes
- ROHS EUR Full Compliance Status
- Compliant with Exemptions
- China ROHS In Scope
- Yes
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- Arc Flash Protection
- no
- Display Type
- LCD 128 x 64 pixels with single line diagram
- Number Of Key
- 2 customizable
- Package Weight Lbs
- 3.792 kg
- Product Or Component Type
- protection relay
- Range Of Product
- PowerLogic P3
- Returnability
- No
- Total Lifecycle Carbon Footprint
- 731 kg CO2 eq.
- Us Rated Supply Voltage2
- 24...48 V AC/DC
- Stocking Flag
- Y
- Pep Code
- ENVPEP1706006EN
- Pep Verification Date
- 2025-07-11
- Psr Version
- PSR-0005-ed3.1-EN-2023 12 08
- Data Source
- extrapolated product
- Functional Unit Unit
- unit
- Energy Model Installation A5 2
- No energy used
- Energy Model End Of Life C1 C4 2
- Global, European and French datasets are used.
- Time Synchronisation Protocol
- SNTP
- Global Commercial Status
- Commercialised
Cybersecuritypassword protection, port hardening
Environmental Characteristicexposure to dry heat Bb EN/IEC 60068-2-2, exposure to cold Ad EN/IEC 60068-2-1, exposure to damp heat in service Db EN/IEC 60068-2-30, exposure to damp heat in service Cab EN/IEC 60068-2-78
Mechanical Robustnessvibrations class II) IEC 60255-21-1, vibrationsFc IEC 60068-2-6, shocks class II) IEC 60255-21-2, shocksEa IEC 60068-2-27, seismic tests method A class II) IEC 60255-21-3
Software NameeSetup Easergy Pro virtual simulation test, Easergy SmartApp
Carbon Footprint Of The Distribution Phase A43.8985926996634443, 4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50.1507432854636962, 0.2 kg CO2 eq.
Carbon Footprint Of The Use Phase B2 B3 B4 B6624 kg CO2 eq., 623.8010019422173
Monitoring Functiontrip circuit supervision 74, circuit breaker monitoring, relay self-monitoring
Number Of Sensors0 temperature sensor(s), 0 arc sensor(s)
Connections Terminals3screw removable (digital input/output), pin removable (voltage transformer), pin removable (current transformer)
Local Publishable Date2025-07-10
ServiceabilityYes
Field Service DivisionDPIBS
Legacy WEEE ScopeIn
EOLI Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
ROHS EUR StatusCompliant with Exemptions
ROHS EUR Full Compliance Status IdCOMPLIANT_WITH_EXEMPTIONS
Green Premium Status For ReportingGreen Premium product
Without Single Use PlasticNo
Return IndicatorN
Device Short NameP3U30-6ABA1BDAB
Mounting Modeflush mounting
Operating Threshold24 V AC/DC
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Protective Treatmentconformal coating
Relay Applicationuniversal
Sustainable PackagingNo
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Medium Descuniversal protection relay, PowerLogic P3U 3CT 1Io 16DI 8DO 24-48V DI24 2LC RL
Product Kit IdentifierN
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent external review
Functional Unit DescriptionOther switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.Protect distribution networks and medium voltage equipment like feeder and motor against faults, (short circuit,over load) 24h per day, for 10 years of continuous operations.
Energy Model Manufacturing A1 A3 2Electricity Mix; Low voltage; 2020; Latvia, LV
Energy Model Use B6 2Electricity Mix; Low voltage; 2020; Asia Pacific, APAC
Single Line Diagram4 controlled + 8 displayed
Web Serverembedded HTTP server
Us Rated Supply Voltage524...48 V AC/DC
Environment Attributes Main
- Take Back
- No, Nej
- Ambient Air Temperature For Storage
- -40-70 °C, -40-70 °C, -40-70 °C, -40-70 °C
- ROHS Exemption Information
- Yes
- China ROHS Regulation
- X
- Circularity Profile
- ENVEOLI1706006_V2
- IP Degree Of Protection
- IP54 front IEC 60529
- Packaging Made With Recycled Cardboard
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Pep Code
- ENVPEP1706006EN
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent external review
Ambient Air Temperature For Operation-40-65 °C, -40-65 °C, -40-65 °C, -40-65 °C
EU ROHS DirectiveCompliant By Exemption , Compliant with Exemptions
Recycled Metal Content At Cr Level0 %
Carbon Footprint730.5411385077375
Environmental DisclosureENVPEP1706006EN
Operating Altitude6561.68 ft (2000 m)
Packaging Without Single Use PlasticNo
Relative Humidity0-95 %, without condensation
Pep Verification Date2025-07-11
Psr VersionPSR-0005-ed3.1-EN-2023 12 08
General Attributes
- Product Or Component Type
- protection relay
Range Of ProductPowerLogic P3
Output Attributes
- Number Of Outputs
- 8 DO, 1 watchdog
Analogue Output Number0
Contractual Warranty Attributes
- Warranty Period
- up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
Warrantyup to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
Input Attributes
- Input Type
- 3 1/5 A CT phase current, 1 1/5 A CT residual current, 4 100 V/110 V VT voltage
- Digital Input Number
- 16
Analogue Input Number0
Specifications
- Depth
- 205 mm
Downloads
Video
Similar Products
You might also be interested in
Loading carousel layout...
Loading carousel layout...
CAD$3137.14/ EA
Loading add to cart quantity...
Need assistance finding the right item?
We can help! Connect with our Sales Team Today!