    Description

    TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

    Features

    • Featuring a highly efficient, built-in 24V DC coil that consumes only 2.4 Watts, this contactor is specifically engineered to interface directly with low-power PLC and automation controller outputs. By eliminating the need for intermediate slave relays, it reduces conFeaturing a highly efficient, built-in 24V DC coil that consumes only 2.4 Watts, this contactor is specifically engineered to interface directly with low-power PLC and automation controller outputs. By eliminating the need for intermediate slave relays, it reduces control cabinet heat generation, slashes component costs, and minimizes overall panel space.trol cabinet heat generation, slashes component costs, and minimizes overall panel space.
    • Rated for 9 Amps (AC-3) at up to 440V AC, this 3-pole device safely manages three-phase motors up to 4 kW (5 HP). It provides a highly reliable, heavy-duty switching architecture for standard industrial automation workloads like small pumps, fans, conveyors, and packaging machinery.
    • Outfitted with pre-assembled, factory-tested 1 Normally Open and 1 Normally Closed auxiliary contacts, this contactor simplifies complex control circuit wiring right out of the box. The mirrored and mechanically linked contact design guarantees reliable feedback to your PLC or safety monitoring loops, preventing hazardous simultaneous engagement scenarios.

    Documentation & Downloads

    Specifications

    Key Specifications

    Country of Origin
    Brazil, France, United Kingdom, Indonesia, Singapore, United States, ZZ
    Depth95 mm

    Complementary Attributes

    Irms Rated Making Capacity
    250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    Control Circuit Type
    DC low consumption
    Maximum Motor Phase Current
    9 A
    Minimum Switching Current
    5 mA for signalling circuit
    Rated Breaking Capacity
    250 A at 440 V for power circuit conforming to IEC 60947
    Maximum Horse Power Rating2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors5 hp at 460/480 V AC 50/60 Hz for 3 phase motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
    Control Circuit Voltage Limits0.1...0.3 Uc (-40-70 °C):drop-out DC0.8...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC
    Maximum Operating Rate3600 cyc/h at 60 °C
    Minimum Switching Voltage17 V for signalling circuit

    Important Information Attributes

    Persona Type Ids
    EU, LC, OM, OM8, PB, SI
    Market Segmentation Id
    COMMERCIAL, INDUSTRIAL
    Contactor Application
    resistive load, motor control
    Insulation Resistance
    > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    Motor Power Kw
    4 kW at 380/400 V AC 50/60 Hz (AC-3e), 4 kW at 415/440 V AC 50/60 Hz (AC-3e), 5.5 kW at 500 V AC 50/60 Hz (AC-3e), 5.5 kW at 660/690 V AC 50/60 Hz (AC-3e), 2.2 kW at 220/230 V AC 50/60 Hz (AC-3)4 kW at 380/400 V AC 50/60 Hz (AC-3), 4 kW at 415/440 V AC 50/60 Hz (AC-3)5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660/690 V AC 50/60 Hz (AC-3), 2.2 kW at 220/230 V AC 50/60 Hz (AC-3e)2.2 kW at 400 V AC 50/60 Hz (AC-4)
    Power Dissipation Per Pole
    1.56 W AC-10.2 W AC-3, 0.2 W AC-3e
    Utilisation Category
    AC-3, AC-3e, AC-1, AC-4
    Certificate Agency
    UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
    [Ui] Rated Insulation Voltage
    signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
    Non-overlap Time
    1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    Carbon Footprint Of The End-of-life Phase [C1 To C4]
    1.2880458349287582, 1 kg CO2 eq.
    Carbon Footprint Of The Manufacturing Phase [A1 To A3]
    3 kg CO2 eq., 2.6596552952376262
    Local Data Status
    Publishable
    Return Indicator
    Y
    Stock Policy
    2
    Serviceability
    No
    Field Service Division
    PPIBS
    Weee Scope
    In
    Scope Perimeter
    At least in Europe
    End Of Life Doc Ref
    ENVEOLI1102030EN
    Reach Full Compliance Status Id
    CONTAINS_SVHC
    Rohs Eur In Scope
    Yes
    Rohs Eur Conformity Date
    1929
    China Rohs In Scope
    No
    Without Single Use Plastic
    Yes
    Tier Id
    1
    Function Option Id
    STANDARD
    Product Kit Identifier
    N
    Average Impedance
    2.5 mOhm - Ith 25 A 50 Hz for power circuit
    Compatibility Code
    LC1D
    Device Short Name
    LC1D
    Flame Retardance
    V1 conforming to UL 94
    Mechanical Durability
    30 Mcycles
    Operating Time
    77 ±15 % ms closing25 ±20 % ms opening
    Pole Contact Composition
    3 NO
    Product Or Component Type
    contactor
    Range Of Product
    TeSys Deca
    Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    Software Version
    v5.9.4
    Time Constant
    40 ms
    Weee Label
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Inf Motor Phase Current
    9 A
    Database Version
    2022-01
    Pcr Version
    PEP-PCR-ed4-2021 09 06
    Type Of Verification For The Pep
    Independent external review
    Functional-unit Description
    Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
    Functional-unit Unit
    unit
    Energy Consumption On Product Lifetime In Kwh
    223.38
    Energy Model - Installation [A5]
    Electricity Mix; Production mix; Low voltage; FR
    Energy Model - End Of Life [C1-c4]
    Electricity Mix; Production mix; Low voltage; FR
    Height Nominal
    77 mm
    [Icw] Rated Short-time Withstand Current
    105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
    [Uc] Control Circuit Voltage
    24 V24 V DC
    [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
    Nbr. Of Units In Pkg.
    1
    Take-back
    No
    Customs Code
    8536490065
    Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    Market SegmentationCommercial, Industrial
    Electrical Durability0.6 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V, 2 Mcycles 9 A AC-3e <= 440 V
    Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    Mounting Supportplate, rail
    Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
    Control Circuit Voltage24 V
    [Ie] Rated Operational Current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    Connections - Terminalspower circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endscrew clamp terminalspower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
    Carbon Footprint Of The Distribution Phase [A4]0.14699424706398806, 0.1 kg CO2 eq.
    Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.04070520226073894
    Carbon Footprint Of The Use Phase [B2 B3 B4 B6]15 kg CO2 eq., 14.925081081081082
    Local Publishable Date2026-07-07
    Stocking FlagN
    Device TypeLV equipment - LV contactor
    TraceabilityNo
    Average Life Duration20 year(s)
    Weee Product Category5
    Eoli Availability DisplayYes
    Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
    Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
    Rohs Eur StatusCompliant By Exemption
    Rohs Eur Full Compliance StatusCompliant By Exemption
    With Recycled CardboardYes
    Product Contributes To Saved And Avoided EmissionsNo
    Tier1
    Function OptionStandard
    Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-125 A gG at <= 690 V coordination type 1 for power circuit20 A gG at <= 690 V coordination type 2 for power circuit
    Coil Technologybuilt-in bidirectional peak limiting diode suppressor
    Contact CompatibilityM5
    Fire Resistance850 °C IEC 60695-2-1
    Inrush Power In W2.4-2.4 W 20 °C)
    Number Of Poles3P
    Overvoltage CategoryIII
    Product AvailabilityStock - Normally stocked in distribution facility
    Protective TreatmentTHIEC 60068-2-30
    ReturnabilityYes
    Signalling Circuit Frequency25...400 Hz
    Sustainable PackagingYes
    Total Lifecycle Carbon Footprint19 kg CO2 eq.
    Connections Terminalsscrew clamp terminals
    Pep CodeENVPEP110230EN
    Pep Verification Date2025-08-05
    Psr VersionPSR-0005-ed2-2016 03 29
    Data Sourceextrapolated product
    Functional-unit Quantity1
    Reference Lifetime In Y20
    Energy Model - Manufacturing [A1-a3]Electricity Mix; Production mix; Low voltage; FR
    Energy Model - Use [B6]Electricity Mix; Production mix; Low voltage; FR
    Recyclability Potential In %75
    Width Nominal45 mm
    [Ith] Conventional Free Air Thermal Current25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
    [Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
    Hold-in Power Consumption In W2.4-2.4 W 20 °C
    Package Weight(Lbs)528.000 g
    Warranty (In Months)18

    Environment Attributes Main

    China Rohs Regulation
    Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    Take Back
    No
    Mercury Free
    Yes
    Circularity Profile
    ENVEOLI1102030EN
    Eu Rohs Directive
    Compliant By Exemption
    Operating Altitude
    0...9842.52 ft (0...3000 m)
    Packaging Without Single Use Plastic
    Yes
    Reach Regulation
    Reference contains Substances of Very High Concern above the threshold
    Pep Verification Date
    2025-08-05
    Psr Version
    PSR-0005-ed2-2016 03 29
    Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    Recycled Metal Content At Cr Level0 %
    Carbon Footprint19.060481660572194
    Environmental DisclosureENVPEP110230EN
    Ip Degree Of ProtectionIP20 front face IEC 60529
    Packaging Made With Recycled CardboardYes
    Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
    Pep CodeENVPEP110230EN
    Pcr VersionPEP-PCR-ed4-2021 09 06
    Type Of Verification For The PepIndependent external review

    General Attributes

    Product Or Component Type
    contactor
    Range Of ProductTeSys Deca

    ETIM

    ETIM 8
    EC000066
    ETIM 9EC000066

    Contractual Warranty Attributes

    Warranty Period
    18 months
    Warranty18 months