TeSys Deca Control Relay 3NO+2NC 24VDC 10A 690V 45mm Width
TeSys Deca Control Relay 3NO+2NC 24VDC 10A 690V 45mm Width
TeSys Deca Control Relay 3NO+2NC 24VDC 10A 690V 45mm Width
Schneider Electric

Schneider Electric CAD32BD TeSys Deca Control Relay 3NO+2NC 24VDC 10A 690V 45mm Width

  • MPN: CAD32BD
  • PPN: SCH-CAD32BD

CAD

$214.42

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 24V DC control circuit with no inrush consumption and equipped with a surge suppression device, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Features

  • The Schneider Electric TeSys Deca CAD32BD features a fixed 5-pole layout containing 3 NO (Normally Open) and 2 NC (Normally Closed) contacts. This specific configuration delivers dedicated, simultaneous signaling loops, allowing automation engineers to seamlessly handle cross-interlocking and run-status logic within a single, space-saving footprint.
  • Engineered for modern, noise-sensitive automation environments, this control relay operates via a standard 24V DC control circuit. The low-consumption DC coil pulls a consistent 5.4W during both inrush and sealed states, preventing voltage sags across your 24V bus and eliminating the inductive electrical noise commonly generated by AC coils.
  • Built to handle rigorous control demands, the relay is rated for a conventional free air thermal current of 10A at temperatures up to 60 C and supports operational voltages up to 690V AC. It conforms to demanding AC-15 and DC-13 utilization categories, providing an instantaneous making capacity of up to 140A AC or 250A DC to safely switch heavy industrial solenoid coils, pilot lights, and contactor coils without premature contact welding.
  • With a compact, space-efficient width of just 45mm, the CAD32BD optimizes critical panel space. It offers dual-mounting flexibility, snapping securely onto a standard 35mm DIN rail or mounting directly to a backplate via screws, letting you quickly swap units or scale out complex multi-relay control arrays.
  • Equipped with robust screw clamp terminals, this device provides gas-tight connections that accommodate flexible or solid conductors ranging from 1 to 4 mm2. Designed to prevent wire pull-outs in high-vibration machinery settings, the terminals handle a high specified tightening torque of 1.7 N m using standard Phillips or flathead screwdrivers for an efficient, repeatable installation process.
  • This industrial-grade control relay holds comprehensive multi-standard certifications, including UL, CSA, CE, UKCA, CCC, and Marine approvals. Its front face features an IP2X finger-safe rating conforming to VDE 0106 standards, ensuring immediate compliance with strict regional electrical inspections and providing essential arc and shock protection for maintenance personnel.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia, Singapore, United States, ZZ
Depth93 mm

Complementary Attributes

Control Circuit Type
DC standard
Irms Rated Making Capacity
140 A AC IEC 60947-5-1250 A DC IEC 60947-5-1
Minimum Switching Current
5 mA
Control Circuit Voltage Limits0.1...0.25 Uc (-40-70 °C):drop-out DC0.7...1.25 Uc (-40-60 °C):operational DC1...1.25 Uc (60-70 °C):operational DC
Maximum Operating Rate180 cyc/mn
Minimum Switching Voltage17 V

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Mechanical Robustness
shocks control relay open10 Gn for 11 ms IEC 60068-2-27shocks control relay closed15 Gn for 11 ms IEC 60068-2-27, vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6, vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
Range
TeSys, TeSys Deca
Utilisation Category
DC-13, AC-15, AC-14
[Ue] Rated Operational Voltage
<= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz<= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz
Connections - Terminals
screw clamp terminals 2 1-2.5 mm²flexible with cable endscrew clamp terminals 2 1-4 mm²solid without cable endscrew clamp terminals 1 1-4 mm²flexible without cable end, screw clamp terminals 2 1-4 mm²flexible without cable end, screw clamp terminals 1 1-4 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²solid without cable end
Carbon Footprint Of The Distribution Phase [A4]
0.17499315126665246, 0.2 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0 kg CO2 eq., 0.048458574119927315
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
33 kg CO2 eq., 32.70348648648649
Local Publishable Date
2026-06-27
Stocking Flag
Y
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant By Exemption
China Rohs In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Associated Fuse Rating
10 A gG conforming to IEC 60947-5-1
Contactor Application
control circuit
Inrush Power In W
5.4-5.4 W 20 °C)
Mechanical Durability
30 Mcycles
Pole Contact Composition
3 NO + 2 NC
Product Name
TeSys CAD
Protective Treatment
TH IEC 60068
Returnability
Yes
Sustainable Packaging
Yes
Total Lifecycle Carbon Footprint
38 kg CO2 eq.
Pole Contact Comp
3 NO + 2 NC
Connections Terminals 55 Connections Terminals
screw clamp terminals
Database Version
2022-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent external review
Functional-unit Description
Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
Functional-unit Unit
unit
Energy Consumption On Product Lifetime In Kwh
489.465
Energy Model - Installation [A5]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]
Electricity Mix; Production mix; Low voltage; FR
Height Nominal
77 mm
[Icw] Rated Short-time Withstand Current
100 A - 1 s120 A - 500 ms140 A - 100 ms
[Uc] Control Circuit Voltage
24 V DC
Hold-in Power Consumption In W
5.4-5.4 W 20 °C
Package Weight(Lbs)
525.000 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Mounting Supportrail, plate
Tightening Torque1.7 N.m screw clamp terminals Philips No 2, 1.7 N.m screw clamp terminals flat Ø 6 mm, 1.7 N.m screw clamp terminals pozidriv No 2
Certificate AgencyCB, CCC, UL, CSA, EAC, CE, UKCA
[Ui] Rated Insulation Voltage600 V UL, 600 V CSA690 V IEC 60947-5-1
Non-overlap Time1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]1.5333878987247123, 2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]3 kg CO2 eq., 3.1662563038543174
Local Data StatusPublishable
Return IndicatorY
Stock Policy1
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1102030EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Full Compliance StatusCompliant By Exemption
China Rohs Label3
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Compatibility CodeCAD
Device Short NameCAD
Insulation Resistance> 10 MOhm> 10 MOhm
Operating Time53...72 ms coil energisation and NO closing16...24 ms coil de-energisation and NO opening47...63 ms coil energisation and NC opening15...25 ms coil de-energisation and NC closing
Product AvailabilityStock - Normally stocked in distribution facility
Product Or Component Typecontrol relay
Range Of ProductTeSys D control relay
Software Versionv5.9.4
Time Constant28 ms
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage 2124 V DC
Pep CodeENVPEP110230EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Production mix; Low voltage; FR
Energy Model - Use [B6]Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential In %75
Width Nominal45 mm
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C)
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Take Back
No
Mercury Free
Yes
Ambient Air Temperature For Operation
-40-60 °C-40-60 °C60-70 °C with derating
Environmental Disclosure
ENVPEP110230EN
Ip Degree Of Protection
IP2X front face VDE 0106
Packaging Made With Recycled Cardboard
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Ambient Air Temperature For Storage-60-80 °C, -60-80 °C
Recycled Metal Content At Cr Level0 %
Carbon Footprint37.6265824144521
Circularity ProfileENVEOLI1102030EN
Eu Rohs DirectiveCompliant By Exemption
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Pep CodeENVPEP110230EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent external review

General Attributes

Product Or Component Type
control relay
Range Of ProductTeSys D control relay

ETIM

ETIM 8
EC000196
ETIM 9EC000196

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Similar Products

Loading carousel layout...

CAD$214.42/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!