TeSys Deca contactor, 4 poles (2NO+2NC), for non-inductive load applications up to 25A/690V AC-1. They can be used to create motor starters for almost any type of application. It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Power contacts have a 25A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Documentation & Downloads

Specifications

Key Specifications

Country of OriginBrazil, France, Indonesia, United States
Depth92 mm

Complementary Attributes

Control Circuit TypeAC 50/60 Hz, AC 50/60 Hz
Irms Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity250 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Inrush Power In Va70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Certificate AgencyUL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
[Ui] Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.05961800783076285
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]32 kg CO2 eq., 31.989018336678964
Local Publishable Date2026-07-15
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Compatibility CodeLC1D
Contactor Applicationresistive load
Electrical Durability0.8 Mcycles 25 A AC-1 <= 440 V
Flame RetardanceV1 conforming to UL 94
Mechanical Durability15 Mcycles
Operating Time12...22 ms closing4...19 ms opening
Pole Contact Composition2 NO + 2 NC
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
ReturnabilityNo
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Utilisation CategoryAC-1
Connections Terminalsscrew clamp terminals
Pep CodeENVPEP1501004EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Installation [A5]No energy used
Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
Height Nominal85 mm
[Icw] Rated Short-time Withstand Current105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Rated Thermal Current (Ith)25 A
Package Weight(Lbs)389.000 g
Warranty (In Months)18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Mounting Supportplate, rail
Control Circuit Voltage220 V
[Uc] Control Circuit Voltage220 V, 220 V AC 50/60 Hz
Connections - Terminalspower circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endscrew clamp terminalspower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.16917571616661592, 0.2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]2 kg CO2 eq., 1.5136785647517297
Local Data StatusPublishable
Return IndicatorN
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1501004
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date2538
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit25 A gG at <= 690 V coordination type 2 for power circuit
Coil Technologywithout built-in suppressor module
Contact CompatibilityM6
Device Short NameLC1D
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation2-3 W at 50/60 Hz
Number Of Poles4P
Overvoltage CategoryIII
Power Dissipation Per Pole1.56 W AC-1
Product Or Component Typecontactor
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Total Lifecycle Carbon Footprint34 kg CO2 eq.
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Thermal Current Hv25 A
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %66
Width Nominal45 mm
[Ie] Rated Operational Current25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In Va7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI1501004
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach Free Of SvhcYes
Pep CodeENVPEP1501004EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint33.73149062542807
Environmental DisclosureENVPEP1501004EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys Deca

ETIM

ETIM 8EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months
TeSys Deca 25A Contactor, 4 Pole, 220V AC Coil, Compact Design