Key Specifications
- Country of Origin
- Brazil, France, Indonesia, United States
Complementary Attributes
- Control Circuit Type
- AC 50/60 Hz, AC 50/60 Hz
- Irms Rated Making Capacity
- 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Minimum Switching Current
- 5 mA for signalling circuit
- Rated Breaking Capacity
- 250 A at 440 V for power circuit conforming to IEC 60947
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Inrush Power In Va
- 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
- Mechanical Robustness
- vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
- Tightening Torque
- control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
- Certificate Agency
- UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
- [Ui] Rated Insulation Voltage
- signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
- Non-overlap Time
- 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
- Carbon Footprint Of The Installation Phase [A5]
- 0.1 kg CO2 eq., 0.05961800783076285
- Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
- 32 kg CO2 eq., 31.989018336678964
- Local Publishable Date
- 2026-07-07
- Stocking Flag
- N
- Device Type
- LV equipment - LV contactor
- Traceability
- No
- Average Life Duration
- 20 year(s)
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Free of Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Free of Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant
- Rohs Eur Full Compliance Status
- Compliant
- China Rohs Label
- 1
- Without Single Use Plastic
- Yes
- Tier Id
- 1
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Average Impedance
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Compatibility Code
- LC1D
- Contactor Application
- resistive load
- Electrical Durability
- 0.8 Mcycles 25 A AC-1 <= 440 V
- Flame Retardance
- V1 conforming to UL 94
- Mechanical Durability
- 15 Mcycles
- Operating Time
- 12...22 ms closing4...19 ms opening
- Pole Contact Composition
- 2 NO + 2 NC
- Product Availability
- Stock - Normally stocked in distribution facility
- Protective Treatment
- THIEC 60068-2-30
- Returnability
- Yes
- Signalling Circuit Frequency
- 25...400 Hz
- Sustainable Packaging
- Yes
- Utilisation Category
- AC-1
- Connections Terminals
- screw clamp terminals
- Pep Code
- ENVPEP1501004EN
- Pep Verification Date
- 2026-03-17
- Psr Version
- PSR-0005-ed3-2023 06 06
- Data Source
- extrapolated product
- Functional-unit Quantity
- 1
- Reference Lifetime In Y
- 20
- Energy Model - Installation [A5]
- No energy used
- Energy Model - End Of Life [C1-c4]
- Global, European and French datasets are used.
- Height Nominal
- 85 mm
- [Icw] Rated Short-time Withstand Current
- 105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
- [Ith] Conventional Free Air Thermal Current
- 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947
- Rated Thermal Current (Ith)
- 25 A
- Package Weight(Lbs)
- 395.000 g
- Warranty (In Months)
- 18
Environment Attributes Main
- China Rohs Regulation
- Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
- Take Back
- No
- Recycled Metal Content At Cr Level
- 0 %
- Mercury Free
- Yes
- Circularity Profile
- ENVEOLI1501004
- Eu Rohs Directive
- Compliant
- Operating Altitude
- 0...9842.52 ft (0...3000 m)
- Packaging Without Single Use Plastic
- Yes
- Reach Free Of Svhc
- Yes
- Pep Code
- ENVPEP1501004EN
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$247.35
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$247.35/ EA
Loading add to cart quantity...