Schneider Electric LC1F185 contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC

contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC
  • MPN: LC1F185
  • PPN: SCH-LC1F185

Spec sheet

Loading compare button...

Available to Order

Company Stock:

0

Lead times may vary. For an accurate estimate please contact us.

Loading dialog...

Looking to buy a large quantity?

To view product inventory

CAD$1492.23/ EA

Description

TeSys F contactor, 3 poles (3NO), 185A/690V AC-3, for motor applications up to 90kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Specifications

Specifications

[Ue] Rated Operational Voltage
<= 690 V AC 50/60 Hz || <= 460 V DC
Product Or Component Type
contactor
Range
TeSys
[Ie] Rated Operational Current
275 A 40 °C) <= 440 V AC-1 || 185 A 55 °C) <= 440 V AC-3
Poles Description
3P
Device Short Name
LC1F
Contactor Applicationresistive load || motor control
Product NameTeSys F
Pole Contact Composition3 NO
Utilisation CategoryAC-3 || AC-4 || AC-1
Motor Power Kw100 kW 415 V AC 50/60 Hz AC-3) || 100 kW 440 V AC 50/60 Hz AC-3) || 110 kW 500 V AC 50/60 Hz AC-3) || 90 kW 380...400 V AC 50/60 Hz AC-3) || 55 kW 220...240 V AC 50/60 Hz AC-3) || 110 kW 660...690 V AC 50/60 Hz AC-3) || 33 kW 400 V AC 50/60 Hz AC-4)

Contractual warranty

Warranty
18 months

Complementary

Product Certifications
ABS || LROS (Lloyds register of shipping) || RINA || CSA || CB || UL || BV || RMRoS || DNV || UKCA
Average Impedance
0.33 mOhm - Ith 275 A 50 Hz
[Ith] Conventional Free Air Thermal Current
275 A 40 °C
[Uc] Control Circuit Voltage
24...575 V AC 40...400 Hz with LX9 coil || 24...460 V DC with LX4 coil || 100...250 V AC 50/60 Hz with LXE coil || 100...380 V DC with LXE coil
Rated Breaking Capacity
1480 A IEC 60947-4-1
Associated Fuse Rating
200 A aM <= 440 V || 315 A gG <= 440 V
Connections - Terminals
power circuit bar 2 25 x 3 mm || power circuit lugs-ring terminals 1 150-150 mm² || power circuit connector 1 150-150 mm² || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² || control circuit screw clamp terminals 1.0 0.2-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1.0 0.25-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1.0 0.2-2.5 mm²solid without cable end
Operating Time
35 ms closing with LX9 coil || 130 ms opening with LX9 coil || 30...40 ms closing with LX4 coil || 30...50 ms opening with LX4 coil || 40...80 ms closing with LXE coil || 6...54 ms opening with LXE coil
Mechanical Durability
10 Mcycles
Hold-In Power Consumption In Va
8.9-10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 4.13-5.07 VA (at 20 °C)with LX4 coil || 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 2.5-4.0 VA (at 20 °C)with LXE coil
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
Heat Dissipation
8-9.8 W || 2.2-2.5 W
Power Dissipation Per Pole25 W AC-1 || 12 W AC-3
Control Circuit Voltage Limitsoperational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil || drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.15...0.2 Uc DC with LX4 coil || operational: 85...275 V AC 50/60 Hz with LXE coil || drop-out: 0...60 V AC 50/60 Hz with LXE coil || operational: 85...418 V DC with LXE coil || drop-out: 0...45 V DC with LXE coil
StandardsIEC 60947-4-1 || EN 60947-1 || JIS C8201-4-1 || EN 60947-4-1 || IEC 60947-1
Mounting Supportplate
Irms Rated Making Capacity1850 A IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage8 kV
Inrush Power In Va950-1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 737-902 VA (at 20 °C)with LX4 coil || 280-310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 270-320 VA (at 20 °C)with LXE coil
Tightening Torquepower circuit 18 N.m || control circuit 1.2 N.m || control circuit 0.6 N.m
Compatibility CodeLC1F
Overvoltage CategoryIII
[Icw] Rated Short-Time Withstand Current1500 A 40 °C - 10 s || 920 A 40 °C - 30 s || 740 A 40 °C - 1 min || 500 A 40 °C - 3 min || 400 A 40 °C - 10 min

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP080208EN
Pvc Free
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity Profile
ENVEOLI100418
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information
Eu Rohs DirectiveCompliant

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed5 Gn, 5...300 Hz || shocks contactor open7 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Height
174 mm
Ambient Air Temperature For Storage
-60-80 °C
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Depth
181 mm
Ambient Air Temperature For Operation-5-55 °C
Net Weight5.45 kg
Protective TreatmentTH
Width168.5 mm
Permissible Ambient Air Temperature Around The Device-40-70 °C

Downloads

Similar Products

Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, <=400V, 50A, 24V DC standard coil, screw clamp terminals

Schneider Electric LC1D50ABD Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, <=400V, 50A, 24V DC standard coil, screw clamp terminals

MPN

LC1D50ABD

Available to Order

Company Stock:

0

CAD$533.46/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, 440V, 80A, 24V DC standard coil, screw clamp terminals

Schneider Electric LC1D80BD Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, 440V, 80A, 24V DC standard coil, screw clamp terminals

MPN

LC1D80BD

Available to Order

Company Stock:

0

CAD$694.29/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, 440V, 80A, 120V AC 50/60Hz coil, screw clamp terminals

Schneider Electric LC1D80G7 Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, 440V, 80A, 120V AC 50/60Hz coil, screw clamp terminals

MPN

LC1D80G7

Available to Order

Company Stock:

0

CAD$587.72/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 12A, 600V AC 50/60Hz coil, screw clamp terminals

Schneider Electric LC1D12X7 Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 12A, 600V AC 50/60Hz coil, screw clamp terminals

MPN

LC1D12X7

Available to Order

Company Stock:

0

CAD$207.97/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 32A, 24V DC coil, screw clamp terminals

Schneider Electric LC1D32BD Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 32A, 24V DC coil, screw clamp terminals

MPN

LC1D32BD

Available to Order

Company Stock:

0

CAD$384.92/EA
Contactor, TeSys K, 3P, AC-3/AC-3e,440V 12A, aux. 1NC, 110V AC coil, screw clamp terminals

Schneider Electric LC1K1201F7 Contactor, TeSys K, 3P, AC-3/AC-3e,440V 12A, aux. 1NC, 110V AC coil, screw clamp terminals

MPN

LC1K1201F7

Available to Order

Company Stock:

0

CAD$96.78/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 24V DC low consumption coil, lugs-ring terminals

Schneider Electric LC1D096BL Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 24V DC low consumption coil, lugs-ring terminals

MPN

LC1D096BL

Available to Order

Company Stock:

0

CAD$218.94/EA
Contactor, Tesys Deca, 3P(3NO), AC-3/AC-3e, <=440V 18A, 24V DC coil, screw clamp terminals

Schneider Electric LC1D18BD Contactor, Tesys Deca, 3P(3NO), AC-3/AC-3e, <=440V 18A, 24V DC coil, screw clamp terminals

MPN

LC1D18BD

Available to Order

Company Stock:

0

CAD$282.23/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 12A, 24V DC coil, screw clamp terminals

Schneider Electric LC1D12BD Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 12A, 24V DC coil, screw clamp terminals

MPN

LC1D12BD

Available to Order

Company Stock:

0

CAD$254.46/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 32A, 24V AC 50/60Hz coil, screw clamp terminals

Schneider Electric LC1D32B7 Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 32A, 24V AC 50/60Hz coil, screw clamp terminals

MPN

LC1D32B7

Available to Order

Company Stock:

0

CAD$337.14/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 24V DC coil, screw clamp terminals

Schneider Electric LC1D09BD Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 24V DC coil, screw clamp terminals

MPN

LC1D09BD

Available to Order

Company Stock:

0

CAD$207.97/EA
Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 18A, 24V AC 50/60Hz coil, screw clamp terminals

Schneider Electric LC1D18B7 Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 18A, 24V AC 50/60Hz coil, screw clamp terminals

MPN

LC1D18B7

Available to Order

Company Stock:

0

CAD$235.09/EA
Loading video…

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

CAD$1492.23/ EA

Loading add to cart quantity...

banner

Need assistance finding the right item?

We can help! Connect with our Sales Team Today!