Designed for robust performance in automation and control systems, the Schneider Electric LC1D80T6 TeSys Deca Contactor is engineered to manage high-load applications with ease. Capable of handling currents up to 80 amps at 480V AC and 60Hz, this device features screw clamp terminals that facilitate secure connections and enhance installation efficiency. With its reliable operation, this contactor is an essential component for starters and control solutions, making it suitable for a wide range of industrial and commercial applications.

Features

  • Designed to meet needs of demanding applications
  • Wide range of accessaries to satisfy different customer usage
  • Digital customer experience for technical documents
  • New modern look & feel of all machines
  • Easier to install and operate with multi-standard screws
  • Multiple and flexible mounting methods depending on exact need

Documentation & Downloads

Specifications

Key Specifications

Country of OriginCzechia, Mexico, United States
Depth130 mm
Weight1758 g

Complementary Attributes

Control Circuit TypeAC 60 Hz, AC 60 Hz
Ie Rated Operational Current125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Ui Rated Insulation Voltagesignalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11100 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit
Icw Rated Short Time Withstand Current640 A 40 °C - 10 s for power circuit990 A 40 °C - 1 s for power circuit135 A 40 °C - 10 min for power circuit320 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Uimp Rated Impulse Withstand Voltage8 kV IEC 60947
Maximum Horse Power Rating30 hp at 230/240 V AC 50/60 Hz for 3 phase motors7.5 hp at 120 V AC 50/60 Hz for 1 phase motors15 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors60 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Uc Control Circuit Voltage480 V, 480 V AC 60 Hz
Control Circuit Voltage Limits0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz0.3...0.6 Uc (-40-70 °C):drop-out AC 60 Hz1...1.1 Uc (55-70 °C):operational AC 60 Hz
Maximum Motor Phase Current80 A
Minimum Switching Current5 mA for signalling circuit
Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947
Ue Rated Operational Voltagepower circuit <= 300 V DC 25...400 Hzpower circuit <= 690 V AC

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SI
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Contactor Applicationresistive load, motor control
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw37 kW at 380...400 V AC 50/60 Hz (AC-3e), 45 kW at 415...440 V AC 50/60 Hz (AC-3e), 55 kW at 500 V AC 50/60 Hz (AC-3e), 45 kW at 660...690 V AC 50/60 Hz (AC-3e)22 kW at 220...230 V AC 50/60 Hz (AC-3)37 kW at 380...400 V AC 50/60 Hz (AC-3)45 kW at 415...440 V AC 50/60 Hz (AC-3)55 kW at 500 V AC 50/60 Hz (AC-3), 45 kW at 660...690 V AC 50/60 Hz (AC-3), 15 kW at 400 V AC 50/60 Hz (AC-4), 22 kW at 220...230 V AC 50/60 Hz (AC-3e)
Power Dissipation Per Pole5.1 W AC-312.5 W AC-1, 5.1 W AC-3e
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
Control Circuit Voltage480 V
Non Overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End Of Life Phase C1 To C44.088997647987764, 4 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A311 kg CO2 eq., 10.960713361237987
Local Data StatusPublishable
Return IndicatorY
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Average Impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Flame RetardanceV1 conforming to UL 94
Inrush Power In Va220-220 VA 60 Hz cos phi 0.75 (at 20 °C)
Number Of Poles3P
Overvoltage CategoryIII
Product AvailabilityStock - Normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv5.9.4
Total Lifecycle Carbon Footprint97 kg CO2 eq.
Inf Motor Phase Current80 A
Data Sourceextrapolated product
Width Nominal85 mm
Customs Code8536490065
Hold In Power Consumption In Va22-22 VA 60 Hz cos phi 0.3 (at 20 °C)
Functional Unit DescriptionSwitch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
Functional Unit Unitunit
Energy Consumption On Product Lifetime In Kwh1215.45
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability0.8 Mcycles 125 A AC-1 <= 440 V, 1.5 Mcycles 80 A AC-3 <= 440 V, 1.5 Mcycles 80 A AC-3e <= 440 V
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz)shocks contactor open 8 Gn for 11 ms)vibrations contactor closed 3 Gn, 5...300 Hz), shocks contactor closed 10 Gn for 11 ms)
Mounting Supportplate, rail
Tightening Torquecontrol circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2power circuit 12 N.m connector flat Ø 6 to Ø 8 mmpower circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Connections Terminalscontrol circuit: 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable endpower circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable endpower circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable endpower circuit: connector 1 4-50 mm² - cable stiffness: solid without cable endpower circuit: connector 2 4-25 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, screw clamp terminals
Certificate AgencyCCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
Carbon Footprint Of The Distribution Phase A40.21622581342878092, 0.2 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50.3 kg CO2 eq., 0.31002666931072853
Carbon Footprint Of The Use Phase B2 B3 B4 B681 kg CO2 eq., 81.20896739130431
Local Publishable Date2026-06-27
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayNo need of specific recycling operations
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1924
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1200 A gG at <= 690 V coordination type 1 for power circuit160 A gG at <= 690 V coordination type 2 for power circuit
Coil Technologywithout built-in suppressor module
Contact CompatibilityM12
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation6-10 W at 60 Hz
Mechanical Durability10 Mcycles
Operating Time20...35 ms closing6...20 ms opening
Pole Contact Composition3 NO
Product Or Component Typecontactor
RangeTeSys
ReturnabilityYes
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Database Version2022-01
Height Nominal127 mm
Nbr. Of Units In Pkg.1
Ith Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit125 A (at 60 °C) for power circuit
Warranty In Months18
Functional Unit Quantity1
Reference Lifetime In Y20
Recyclability Potential In %76

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint96.78493088326958
Environmental DisclosureENVPEP1102005EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Climatic WithstandIACS E10 exposure to damp heat
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach Free Of SvhcYes
Pep CodeENVPEP1102005EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Typecontactor
Range Of ProductTeSys Deca

ETIM

ETIM 8EC000066
ETIM 10EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty18 months