


Documentation & Downloads

Schneider Electric LP1K1210BD TeSys K Contactor 3P 440V 12A with 1NO Auxiliary Contact, 24V DC Coil
- MPN: LP1K1210BD
- PPN: SCH-LP1K1210BD
CAD
$124.06
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
Description
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- Brazil, France, Indonesia, United States
Complementary Attributes
- Control Circuit Type
- DC standard
- Irms Rated Making Capacity
- 144 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
- Maximum Operating Rate
- 3600 cyc/h
- Minimum Switching Voltage
- 17 V for signalling circuit
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
- Electrical Durability
- 1.3 Mcycles 12 A AC-3 <= 440 V, 1.3 Mcycles 12 A AC-3e <= 440 V0.3 Mcycles 20 A AC-1 <= 690 V, 0.02 Mcycles 72 A AC-4 <= 440 V
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Mounting Support
- plate, rail
- Utilisation Category
- AC-3, AC-3e, AC-1, AC-4
- [Ie] Rated Operational Current
- 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
- [Uc] Control Circuit Voltage
- DC, 24 V
- [Ui] Rated Insulation Voltage
- signalling circuit 600 V UL 508signalling circuit 600 V CSA C22.2 No 14power circuit 600 V UL 508power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-5-1, power circuit 600 V CSA C22.2 No 14
- Carbon Footprint Of The Distribution Phase [A4]
- 0.4419444177757305, 0.4 kg CO2 eq.
- Carbon Footprint Of The Installation Phase [A5]
- 0 kg CO2 eq., 0.030381843366423737
- Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
- 117 kg CO2 eq., 116.84560644093847
- Local Publishable Date
- 2026-06-27
- Stocking Flag
- N
- Device Type
- LV equipment - LV contactor
- Traceability
- No
- Average Life Duration
- 20 year(s)
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Free of Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Free of Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant
- Rohs Eur Full Compliance Status
- Compliant
- With Recycled Cardboard
- Yes
- Product Contributes To Saved And Avoided Emissions
- No
- Tier
- 1
- Function Option
- Standard
- Average Impedance
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Compatibility Code
- LP1K
- Heat Dissipation
- 1.3-1.3 W
- Mechanical Durability
- 10 Mcycles
- Operating Time
- 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening
- Pole Contact Composition
- 3 NO
- Product Or Component Type
- contactor
- Range Of Product
- TeSys K
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Sustainable Packaging
- Yes
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Database Version
- 2024-01
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Consumption On Product Lifetime In Kwh
- 289.08
- Energy Model - Installation [A5]
- No energy used
- Energy Model - End Of Life [C1-c4]
- Global, European and French datasets are used.
- Height Nominal
- 58 mm
- [Icw] Rated Short-time Withstand Current
- 115 A 50 °C - 1 s for power circuit105 A 50 °C - 5 s for power circuit100 A 50 °C - 10 s for power circuit75 A 50 °C - 30 s for power circuit55 A 50 °C - 1 min for power circuit50 A 50 °C - 3 min for power circuit25 A 50 °C - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
- Hold-in Power Consumption In W
- 3-3 W 20 °C
- Package Weight(Lbs)
- 223.000 g
- Warranty (In Months)
- 18
Environment Attributes Main
- Ambient Air Temperature For Storage
- -50-80 °C, -50-80 °C
- Take Back
- No
- Recycled Metal Content At Cr Level
- 0 %
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 118.78395455168616
- Circularity Profile
- ENVEOLI1503003
- Eu Rohs Directive
- Compliant
- Operating Altitude
- 6561.68 ft (2000 m) without derating
- Packaging Without Single Use Plastic
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Pep Verification Date
- 2026-03-23
- Psr Version
- PSR-0005-ed3-2023 06 06
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$124.06
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$124.06/ EA
Loading add to cart quantity...












