Schneider Electric

Schneider Electric LC1D150ABNE Contactor, Tesys Deca Advanced, 3P(3NO), 100hp at 480V, 150A, 24-60V AC/DC coil, Everlink

Contactor, Tesys Deca Advanced, 3P(3NO), 100hp at 480V, 150A, 24-60V AC/DC coil, Everlink
Contactor, Tesys Deca Advanced, 3P(3NO), 100hp at 480V, 150A, 24-60V AC/DC coil, Everlink
  • MPN: LC1D150ABNE
  • PPN: SCH-LC1D150ABNE
  • UNSPSC: 39121529

Spec sheet

Loading compare button...

In Stock

Company Stock:

00

Lead times may vary. For an accurate estimate please contact us.

Loading dialog...

Looking to buy a large quantity?

To view product inventory

CAD$1351.75/ EA

Description

TeSys Deca Advanced contactor, 3 poles (3NO) for motor control applications up to 100hp at 480V, 160A general purpose It is equipped with a 24-60V AC/DC wide-band electronic coil that has lower power consumption, along with integrated 1NO+1NC auxiliary contacts. It can be installed in any orientation, and LRD43 could be directly mounted below contactor. The operating temperature range is between -40°C and 70°C, and it can be installed at altitudes of up to 3000m without derating. It is designed for demanding applications with improved performance under harsh environment including salt-mist, dust and high shock. The dimension is 152mm x 97mm x 155mm (H x W x D). Compact size enables panel space savings. Simple wiring with all front access to control circuit enhances accessibility and safety.

Features

  • Efficient solution combining robustness with ease of use, ensuring customers experience reliability without complexity
  • Electronic wide-band coil withstands voltage fluctuations allows quick coil operating frequency and ensures long uptime
  • Sustainability is advanced with 50% coil inrush savings.
  • Fewer references covering wider applications means simpler to select and less inventory to carry
  • Compact size with robust EverLink power connection improves operational efficiency and eliminates future maintenance
  • Unique QR code supports quick access to product data, anti-counterfeit checking and digital assets

Specifications

Conformance Attributes

Product Certifications
CB Scheme, CCC, cULus, CE, UKCA, EU-RO-MR by DNV-GL
StandardsEN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, JIS C8201-4-1, JIS C8201-5-1, GB/T 14048.4, GB/T 14048.5

Complementary Attributes

Control Circuit Type
AC 50/60 Hz, DC
IRMS Rated Making Capacity
1885 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Operating Rate
2400 cyc/h at 60 °C, 3600 cyc/h at Uc at 20 ºC
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
1440 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.8 Uc Min...1.1 Uc Max (-40-60 °C):operational AC/DC, 0.1 Uc Max (-40-60 °C):drop-out AC/DC
Maximum Horse Power Rating40 hp at 200/208 V 60 Hz, 50 hp at 230/240 V 60 Hz, 100 hp at 460/480 V 60 Hz, 125 hp at 575/600 V 60 Hz
Maximum Motor Phase Current150 A
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
160 A aM at <= 440 V for power circuit, 125 A aM at <= 690 V for power circuit, 250 A gG at <= 690 V for power circuit, 10 A gG for signalling circuit, 2 A gG for control circuit
Electrical Durability
0.85 Mcycles 150 A AC-3 <= 440 V, 0.85 Mcycles 150 A AC-3e <= 440 V, 0.5 Mcycles 200 A AC-1 <= 440 V
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) IEC 60068-2-6, vibrations contactor closed 4 Gn, 5...300 Hz) IEC 60068-2-6, shocks contactor open 10 Gn for 11 ms) IEC 60068-2-27, shocks contactor closed 15 Gn for 11 ms) IEC 60068-2-27
Non Overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Power Dissipation Per Pole
8 W AC-3, 8 W AC-3e, 22 W AC-1
Tightening Torque
power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Icw Rated Short Time Withstand Current2
350 A 40 °C - 10 min for power circuit, 600 A 40 °C - 1 min for power circuit, 1280 A 40 °C - 10 s for power circuit, 1800 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Uc Control Circuit Voltage2
24...48 V, 24...60 V AC 50/60 Hz, 24...60 V DC
Ui Rated Insulation Voltage2
power circuit 600 V CSA, power circuit 600 V UL, power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Carbon Footprint Of The End Of Life Phase C1 To C4
5.454633408348155, 5 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3
26 kg CO2 eq., 25.87910123592437
Connections Terminals
connector, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
Icw Rated Short Time Withstand Current5
350 A 40 °C - 10 min for power circuit, 600 A 40 °C - 1 min for power circuit, 1280 A 40 °C - 10 s for power circuit, 1800 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Uc Control Circuit Voltage5
24...60 V AC 50/60 Hz, 24...60 V DC
Ui Rated Insulation Voltage5
power circuit 600 V CSA, power circuit 600 V UL, power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL
Local Publishable Date
2025-12-03
Serviceability
No
Field Service Division
PPIBS
Legacy WEEE Scope
In
EOLI Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
ROHS EUR Status
Compliant with Exemptions
ROHS EUR Full Compliance Status Id
COMPLIANT_WITH_EXEMPTIONS
Green Premium Status For Reporting
Green Premium product
Without Single Use Plastic
No
Return Indicator
Y
Function Option
Standard
Coil Technology
built-in bidirectional peak limiting diode suppressor
Device Short Name
LC1D
Halogen Free Status
Halogen free plastic parts product
Hold In Power Consumption In VA
7.5-7.5 VA (at 20 °C)
Inrush Power In VA
170-170 VA (at 20 °C)
Mechanical Durability
8 Mcycles
Overvoltage Category
III
Pole Contact Composition
3 NO
Product Availability
Stock - Normally stocked in distribution facility
Protective Treatment
noneIEC 60068-2-30
Range Of Product
TeSys Deca Advanced
Signalling Circuit Frequency
16.67...400 Hz
Total Lifecycle Carbon Footprint
362 kg CO2 eq.
Ith Conventional Free Air Thermal Current2
200 A (at 60 °C) for power circuit
Medium Desc
Contactor, Tesys Deca Advanced, 3P(3NO), 100hp at 480V, 150A, 24-60V AC/DC coil, Everlink
Stocking Flag
N
Pep Code
ENVPEP2408027
Pep Verification Date
2025-08-11
Psr Version
PSR-0005-ed3.1-EN-2023 12 08
Data Source
extrapolated product
Functional Unit Unit
unit
Energy Model Installation A5 2
Electricity Mix; Low voltage; 2018; Europe, EU-27
Energy Model End Of Life C1 C4 2
Electricity Mix; Low voltage; 2018; Europe, EU-27
Ith Conventional Free Air Thermal Current5
200 A (at 60 °C) for power circuit
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power KW75 kW at 400 V AC 50/60 Hz (AC-3e), 80 kW at 415 V AC 50/60 Hz (AC-3e), 90 kW at 440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e), 75 kW at 400 V AC 50/60 Hz (AC-4), 75 kW at 440 V AC 50/60 Hz (AC-4), 75 kW at 500 V AC 50/60 Hz (AC-4), 80 kW at 690 V AC 50/60 Hz (AC-4), 40 kW at 230 V AC 50/60 Hz (AC-3), 75 kW at 400 V AC 50/60 Hz (AC-3), 80 kW at 415 V AC 50/60 Hz (AC-3), 90 kW at 440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 40 kW at 230 V AC 50/60 Hz (AC-3e), 37 kW at 230 V AC 50/60 Hz (AC-4), 65 kW at 1000 V AC 50/60 Hz (AC-4)
Operating Time10...80 ms opening, 20...90 ms closing
Safety Reliability LevelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4, DC-1, DC-3, DC-5
Ie Rated Operational Current2150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Ue Rated Operational Voltage2power circuit <= 1000 V AC 16.67...400 Hz, power circuit <= 300 V DC
Carbon Footprint Of The Distribution Phase A40.3996432973200851, 0.4 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50.3 kg CO2 eq., 0.2902760592674699
Carbon Footprint Of The Use Phase B2 B3 B4 B6330 kg CO2 eq., 330.31988414226987
Connections Terminals3power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
Ie Rated Operational Current5150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Ue Rated Operational Voltage5power circuit <= 1000 V AC 16.67...400 Hz, power circuit <= 300 V DC
Local Data StatusPublishable
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI2408027
Reach Full Compliance Status IdCONTAINS_SVHC
ROHS EUR In ScopeYes
ROHS EUR Full Compliance StatusCompliant with Exemptions
China ROHS In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Function Option IdSTANDARD
Average Impedance0.45 mOhm - Ith 200 A 50 Hz for power circuit
Compatibility CodeLC1D
Fire Resistance850 °C IEC 60695-2-11
Heat Dissipation2.2-2.2 W at 20 °C
Hold In Power Consumption In W5.1-5.1 W 20 °C
Inrush Power In W136-136 W 20 °C)
Mounting Supportplate
Package Weight Lbs2.62 kg
Poles Description3P
Product Or Component Typecontactor
RangeTeSys Deca
ReturnabilityYes
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Uimp Rated Impulse Withstand Voltage28 kV IEC 60947
Country Of Origin 6US
Product Kit IdentifierN
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional Unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 yearsEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts 3O, a rated voltage up to 1000V, a rated current AC3 115A, a control circuit voltage 100-250VAC/DC, with 3 poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Energy Model Manufacturing A1 A3 2China, CN
Energy Model Use B6 2Electricity Mix; Low voltage; 2018; Europe, EU-27
Global Commercial StatusCommercialised
Uimp Rated Impulse Withstand Voltage58 kV IEC 60947

Environment Attributes Main

Take Back
Nej, No
Climatic Withstand
IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device
-40-60 °C operation, -40-60 °C operation, -60-80 °C storage, -60-80 °C storage, -40-60 °C operation, -40-60 °C operation, 60-70 °C with derating, -60-80 °C storage, -60-80 °C storage
Halogene Performance
Halogen free plastic parts product
Mercury Free
Yes
Circularity Profile
ENVEOLI2408027
Halogen Content Performance
Halogen free plastic parts product
Operating Altitude
0...9842.52 ft (0...3000 m) without derating
Packaging Without Single Use Plastic
No
Pep Code
ENVPEP2408027
Pcr Version
PCR-4-ed4-EN-2021 09 06
Type Of Verification For The Pep
Independent internal review
China ROHS RegulationProduct out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
EU ROHS DirectiveCompliant By Exemption , Compliant with Exemptions
ROHS Exemption InformationYes
Recycled Metal Content At Cr Level0 %
Carbon Footprint362.34353814313
Environmental DisclosureENVPEP2408027
IP Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2025-08-11
Psr VersionPSR-0005-ed3.1-EN-2023 12 08

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca Advanced

Specifications

Country of Origin
Indonesia, Philippines
Depth155 mm

Downloads

Video

Similar Products

TeSys Deca Contactor Coil 110V AC 50/60Hz for 115A & 150A Contactors

Schneider Electric LX1D8F7 TeSys Deca Contactor Coil 110V AC 50/60Hz for 115A & 150A Contactors

MPN

LX1D8F7

In Stock

Company Stock:

00

CAD$236.94/EA
TeSys Deca Contactor Coil 24V AC 50/60Hz for LC1D09-D38, 0.07 kg

Schneider Electric LXD1B7 TeSys Deca Contactor Coil 24V AC 50/60Hz for LC1D09-D38, 0.07 kg

MPN

LXD1B7

In Stock

Company Stock:

00

CAD$117.98/EA
TeSys Deca Contactor 3P 150A 120V AC Coil, IP20

Schneider Electric LC1D150G7 TeSys Deca Contactor 3P 150A 120V AC Coil, IP20

MPN

LC1D150G7

In Stock

Company Stock:

00

CAD$1317.52/EA
TeSys Deca Contactor Coil 220V AC 50/60Hz for 80 & 95A Contactors

Schneider Electric LX1D6M7 TeSys Deca Contactor Coil 220V AC 50/60Hz for 80 & 95A Contactors

MPN

LX1D6M7

In Stock

Company Stock:

00

CAD$190.51/EA
TeSys Deca Contactor Coil 48V AC 50/60Hz for 9-38A Contactors

Schneider Electric LXD1E7 TeSys Deca Contactor Coil 48V AC 50/60Hz for 9-38A Contactors

MPN

LXD1E7

In Stock

Company Stock:

00

CAD$117.98/EA
TeSys Deca Contactor Coil 120V AC 50/60Hz for 9-38A Contactors

Schneider Electric LXD1G7 TeSys Deca Contactor Coil 120V AC 50/60Hz for 9-38A Contactors

MPN

LXD1G7

In Stock

Company Stock:

00

CAD$117.98/EA
TeSys Deca Contactor Coil 120V AC, 80A/95A, 32 Ohm, 4 Mcycles

Schneider Electric LX1D6G7 TeSys Deca Contactor Coil 120V AC, 80A/95A, 32 Ohm, 4 Mcycles

MPN

LX1D6G7

In Stock

Company Stock:

00

CAD$190.51/EA
TeSys Deca Contactor Coil 600 V AC 9-38A, 0.07 kg, 3600 cyc/h

Schneider Electric LXD1X7 TeSys Deca Contactor Coil 600 V AC 9-38A, 0.07 kg, 3600 cyc/h

MPN

LXD1X7

In Stock

Company Stock:

00

CAD$117.98/EA
TeSys Deca Contactor Coil, 575 V AC, 9-38 A, PVC Free, 0.07 kg

Schneider Electric LXD1SC7 TeSys Deca Contactor Coil, 575 V AC, 9-38 A, PVC Free, 0.07 kg

MPN

LXD1SC7

In Stock

Company Stock:

00

CAD$102.91/EA
TeSys Deca Contactor Coil, 240V AC 50/60Hz, 9-38A, 0.07 kg

Schneider Electric LXD1U7 TeSys Deca Contactor Coil, 240V AC 50/60Hz, 9-38A, 0.07 kg

MPN

LXD1U7

In Stock

Company Stock:

00

CAD$117.98/EA
TeSys Deca Contactor Coil, 208V AC, 9-38A, 3600 cyc/h

Schneider Electric LXD1LE7 TeSys Deca Contactor Coil, 208V AC, 9-38A, 3600 cyc/h

MPN

LXD1LE7

In Stock

Company Stock:

00

CAD$117.98/EA
TeSys Deca 3P Contactor, 65A, 24V DC Coil, 55mm Width

Schneider Electric LC1D65ABD TeSys Deca 3P Contactor, 65A, 24V DC Coil, 55mm Width

MPN

LC1D65ABD

In Stock

Company Stock:

00

CAD$614.20/EA

Others Also Viewed

Loading carousel layout...

CAD$1351.75/ EA

Loading add to cart quantity...

banner
Need assistance finding the right item?