Documentation & Downloads

Schneider Electric LC1D12LE7 TeSys Deca Contactor 3P 12A 208V AC Coil, Compact Design
- MPN: LC1D12LE7
- PPN: SCH-LC1D12LE7
CAD
$207.97
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
Description
Features
- Engineered specifically with a 208V AC 50/60Hz control coil, this TeSys Deca non-reversing contactor matches standard commercial and industrial power distribution systems seamlessly. It eliminates the need for expensive control transformers or step-down modifications, ensuring immediate compatibility with your existing 208V control loops.
- Outfitted standard with 1 NO (Normally Open) and 1 NC (Normally Closed) integrated auxiliary contacts, this device allows you to run status indications or safety interlocks without purchasing add-on blocks. The built-in NC contact features mirror-contact certification, ensuring safe and predictable behavior for critical machinery monitoring applications.
- Featuring a highly compact 45mm width, this space-saving design snaps directly onto standard 35mm DIN rails or mounts via traditional screw fixing. The standard screw clamp terminal architecture provides a secure, vibration-resistant connection, while the IP20 finger-safe design protects maintenance technicians from accidental contact.
- This industrial-grade contactor is fully certified under UL, CSA, CE, UKCA, CCC, and Marine standards, clearing any regulatory hurdles for equipment deployment across North America and abroad. Rest assured knowing the TeSys Deca family complies with the rigorous IEC 60947-4-1 standard to ensure predictable performance over millions of operating cycles.
Documentation & Downloads
Specifications
Key Specifications
- Country of Origin
- France, Indonesia, Mexico, United States
Complementary Attributes
- Control Circuit Voltage Limits
- 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
- Maximum Horse Power Rating
- 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors0.5 hp at 115 V AC 50/60 Hz for 1 phase motors, 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 10 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Maximum Motor Phase Current
- 12 A
- Minimum Switching Current
- 5 mA for signalling circuit
- Rated Breaking Capacity
- 250 A at 440 V for power circuit conforming to IEC 60947
Important Information Attributes
- Persona Type Ids
- EU, LC, OM, OM8, PB, SI
- Market Segmentation Id
- COMMERCIAL, INDUSTRIAL
- Associated Fuse Rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 2 for power circuit
- Electrical Durability
- 2 Mcycles 12 A AC-3 <= 440 V, 0.8 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 12 A AC-3e <= 440 V
- Insulation Resistance
- > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Motor Power Kw
- 5.5 kW at 380...400 V AC 50/60 Hz (AC-3e), 5.5 kW at 415...440 V AC 50/60 Hz (AC-3e), 7.5 kW at 500 V AC 50/60 Hz (AC-3e), 7.5 kW at 660...690 V AC 50/60 Hz (AC-3e)3 kW at 220...230 V AC 50/60 Hz (AC-3), 5.5 kW at 380...400 V AC 50/60 Hz (AC-3), 5.5 kW at 415...440 V AC 50/60 Hz (AC-3), 7.5 kW at 500 V AC 50/60 Hz (AC-3), 7.5 kW at 660...690 V AC 50/60 Hz (AC-3), 3.7 kW at 400 V AC 50/60 Hz (AC-4), 3 kW at 220...230 V AC 50/60 Hz (AC-3e)
- Operating Time
- 12...22 ms closing, 4...19 ms opening
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Utilisation Category
- AC-1, AC-3, AC-4, AC-3e
- [Icw] Rated Short-time Withstand Current
- 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
- [Ith] Conventional Free Air Thermal Current
- 25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
- [Ue] Rated Operational Voltage
- power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
- Connections - Terminals
- power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, screw clamp terminals, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
- Non-overlap Time
- 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
- Carbon Footprint Of The Installation Phase [A5]
- 0.1 kg CO2 eq., 0.05308452752054227
- Carbon Footprint Of The Use Phase [B2, B3, B4, B6]
- 22 kg CO2 eq., 21.825019899655352
- Local Publishable Date
- 2025-05-31
- Stocking Flag
- N
- Device Type
- LV equipment - LV contactor
- Traceability
- No
- Average Life Duration
- 20 year(s)
- Weee Product Category
- 5
- Eoli Availability Display
- Yes
- Reach Full Compliance Status
- Free of Substances of Very High Concern above the threshold
- Reach Compliance Directive
- Free of Substances of Very High Concern above the threshold
- Rohs Eur Status
- Compliant
- Rohs Eur Full Compliance Status
- Compliant
- China Rohs Label
- 1
- Without Single Use Plastic
- Yes
- Tier Id
- 1
- Function Option Id
- STANDARD
- Product Kit Identifier
- N
- Coil Technology
- without built-in suppressor module
- Contact Compatibility
- M2
- Fire Resistance
- 850 °C IEC 60695-2-1
- Heat Dissipation
- 2-3 W at 50/60 Hz
- Number Of Poles
- 3P
- Pole Contact Composition
- 3 NO
- Product Or Component Type
- contactor
- Range Of Product
- TeSys Deca
- Signalling Circuit Frequency
- 25...400 Hz
- Sustainable Packaging
- Yes
- Weee Label
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Inf Motor Phase Current
- 12 A
- Database Version
- 2024-01
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
- Functional-unit Description
- Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
- Functional-unit Unit
- unit
- Energy Model - Manufacturing [A1-a3]
- Electricity Mix; Low voltage; 2020; France, FR
- Energy Model - Use [B6]
- Electricity Mix; Low voltage; 2020; France, FR
- Recyclability Potential, In %
- 66
- Width Nominal
- 45 mm
- Nbr. Of Units In Pkg.
- 1
- Take-back
- No
Environment Attributes Main
- China Rohs Regulation
- Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
- Permissible Ambient Air Temperature Around The Device
- -40-60 °C-40-60 °C, 60-70 °C with derating
- Reach Free Shvc
- Yes
- Toxic Heavy Metal Free
- Yes
- Carbon Footprint
- 23.376536321144286
- Environmental Disclosure
- ENVPEP1501004EN
- Ip Degree Of Protection
- IP20 front face IEC 60529
- Packaging Made With Recycled Cardboard
- Yes
- Reach Free Of Svhc
- Yes
- Pep Code
- ENVPEP1501004EN
- Pcr Version
- PEP-PCR-ed4-2021 09 06
- Type Of Verification For The Pep
- Independent internal review
General Attributes
- Product Or Component Type
- contactor
ETIM
- ETIM 8
- EC000066
Contractual Warranty Attributes
- Warranty Period
- 18 months
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$207.97
/ EA
Lead times may vary. For an accurate estimate please contact us.
Company Stock:
0
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Spec sheet
CAD$207.97/ EA
Loading add to cart quantity...