TeSys Deca Contactor 3P 38A 440V AC 48...130V Coil
TeSys Deca Contactor 3P 38A 440V AC 48...130V Coil
TeSys Deca Contactor 3P 38A 440V AC 48...130V Coil
Schneider Electric

Schneider Electric LC1D38EHE TeSys Deca Contactor 3P 38A 440V AC 48...130V Coil

  • MPN: LC1D38EHE
  • PPN: SCH-LC1D38EHE

CAD

$454.68

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys Deca Contactor 3P 38A 440V AC 48...130V Coil

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France
Depth92 mm

Complementary Attributes

Control Circuit Type
AC/DC 50/60 Hz AC/DC electronic, AC/DC 50/60 Hz AC/DC electronic
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
Maximum Motor Phase Current
38 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
550 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC
Maximum Horse Power Rating10 hp at 230/240 V AC 60 Hz for 3 phase motors2 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 460/480 V AC 60 Hz for 3 phase motors, 25 hp at 575/600 V AC 60 Hz for 3 phase motors
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
1.8 Mcycles 35 A AC-3 <= 440 V, 0.9 Mcycles 50 A AC-1 <= 440 V, 1.8 Mcycles 35 A AC-3e <= 440 V
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms)
Mounting Support
plate, rail
Power Dissipation Per Pole
5 W AC-1, 3 W AC-3, 3 W AC-3e
Tightening Torque
power circuit 2.5 N.m screw clamp terminals Philips No 2control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm, power circuit 2.5 N.m screw clamp terminals pozidriv No 2 M4, control circuit 1.7 N.m screw clamp terminals pozidriv No 2 M3.5
Certificate Agency
CCC, CSA, EAC, UL, KC, DNV-GL, LROS (Lloyds register of shipping), UKCA
[Ie] Rated Operational Current
50 A (at <60 °C) at <= 440 V AC-1 for power circuit, 38 A (at <60 °C) at <= 440 V AC-3 for power circuit, 38 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] Control Circuit Voltage
48...130 V, 48...130 V AC 50/60 Hz, 48...130 V DC
Connections - Terminals
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid, screw clamp terminals, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
Carbon Footprint Of The Distribution Phase [A4]
0.13110404738456014, 0.1 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0 kg CO2 eq., 0.04894039295233771
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]
18 kg CO2 eq., 17.851168421052634
Local Publishable Date
2025-07-01
Stocking Flag
Y
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant By Exemption
Rohs Eur Full Compliance Status
Compliant By Exemption
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Average Impedance
2 mOhm - Ith 50 A 50 Hz for power circuit
Compatibility Code
LC1D
Fire Resistance
850 °C IEC 60695-2-1
Heat Dissipation
0.8-0.8 W at 50/60 Hz
Inrush Power In W
24-24 W 20 °C)
Number Of Poles
3P
Pole Contact Composition
3 NO
Product Or Component Type
contactor
Returnability
No
Software Version
v5.9.4
Total Lifecycle Carbon Footprint
22 kg CO2 eq.
Connections Terminals
screw clamp terminals
Inf Motor Phase Current
38 A
Database Version
2022-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3 NO, a control circuit voltage 250V, a power circuit voltage 690V and a rated operational current 9A.
Functional-unit Unit
unit
Energy Consumption On Product Lifetime, In Kwh
267.18
Energy Model - Installation [A5]
Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]
Electricity Mix; Production mix; Low voltage; FR
Height Nominal
85 mm
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz
Hold-in Power Consumption In Va
1.3-1.3 VA 50/60 Hz (at 20 °C)
Halogen-free Status
Halogen free plastic parts and cables product
Package Weight(Lbs)
460.0 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationresistive load, motor control
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw18.5 kW at 380...400 V AC 50 Hz (AC-3e), 18.5 kW at 415 V AC 50 Hz (AC-3e), 18.5 kW at 440 V AC 50 Hz (AC-3e), 18.5 kW at 500 V AC 50 Hz (AC-3e), 18.5 kW at 660...690 V AC 50 Hz (AC-3e)9 kW at 220...230 V AC 50 Hz (AC-3), 18.5 kW at 380...400 V AC 50 Hz (AC-3), 18.5 kW at 415 V AC 50 Hz (AC-3), 18.5 kW at 440 V AC 50 Hz (AC-3), 18.5 kW at 500 V AC 50 Hz (AC-3), 18.5 kW at 660...690 V AC 50 Hz (AC-3), 9 kW at 220...230 V AC 50 Hz (AC-3e)
Operating Time45...55 ms closing, 20...90 ms opening
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation CategoryAC-3, AC-1, AC-3e
[Icw] Rated Short-time Withstand Current100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 60 A 40 °C - 10 min for power circuit, 150 A 40 °C - 1 min for power circuit, 310 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
[Ui] Rated Insulation Voltagepower circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]0.752088935475424, 0.8 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]4 kg CO2 eq., 3.631155218883696
Local Data StatusPublishable
Return IndicatorN
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1609001EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1922
China Rohs In ScopeNo
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologybuilt-in bidirectional peak limiting
Device Short NameLC1D
Flame RetardanceV1 conforming to UL 94
Inrush Power In Va25-25 VA 50/60 Hz (at 20 °C)
Mechanical Durability15 Mcycles
Overvoltage CategoryIII
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Range Of ProductTeSys Deca Advanced
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage48...130 V
Pep CodeENVPEP1609001EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed2-2016 03 29
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime, In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Production mix; Low voltage; FR
Energy Model - Use [B6]Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential, In %70
Width Nominal45 mm
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Hold-in Power Consumption In W0.8-0.8 W 20 °C
Nbr. Of Units In Pkg.1
Take-backNo

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Permissible Ambient Air Temperature Around The Device
-40-60 °C-40-60 °C, 60-70 °C with derating
Halogene Performance
Halogen free plastic parts & cables product
Mercury Free
Yes
Circularity Profile
ENVEOLI1609001EN
Eu Rohs Directive
Compliant By Exemption
Ip Degree Of Protection
IP20 front face IEC 60529
Packaging Made With Recycled Cardboard
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Take BackNo
Recycled Metal Content At Cr Level0 %
Carbon Footprint22.414457015748653
Environmental DisclosureENVPEP1609001EN
Halogen Content PerformanceHalogen free plastic parts & cables product
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Pep CodeENVPEP1609001EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca Advanced

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$454.68/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])