TeSys Deca Contactor 3P 65A 100-250V AC/DC Coil
TeSys Deca Contactor 3P 65A 100-250V AC/DC Coil
Schneider Electric

Schneider Electric LC1D65AKUE TeSys Deca Contactor 3P 65A 100-250V AC/DC Coil

  • MPN: LC1D65AKUE
  • PPN: SCH-LC1D65AKUE
  • If you can't find the product or are unsure which one you need, please use the Product Selector tool below
  • CAD

    $614.20

    / EA

    Available to Order

    Lead times may vary. For an accurate estimate please contact us.

    Available To Ship Immediately:0

    Loading dialog...

    Looking to buy a large quantity?

    To View Branch Inventory And Your Custom Pricing

    Spec sheet

    Description

    TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3/3e (30kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 100-250V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.21 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

    Documentation & Downloads

    Specifications

    Key Specifications

    Country of Origin
    France, United States
    Depth120 mm

    Complementary Attributes

    Control Circuit Type
    AC/DC 50/60 Hz AC/DC electronic, AC/DC 50/60 Hz AC/DC electronic
    Maximum Horse Power Rating
    20 hp at 230/240 V AC 60 Hz for 3 phase motors5 hp at 115 V AC 60 Hz for 1 phase motors10 hp at 230/240 V AC 60 Hz for 1 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors40 hp at 460/480 V AC 60 Hz for 3 phase motors50 hp at 575/600 V AC 60 Hz for 3 phase motors
    Maximum Motor Phase Current
    65 A
    Minimum Switching Current
    5 mA for signalling circuit
    Rated Breaking Capacity
    1000 A at 440 V for power circuit conforming to IEC 60947
    Control Circuit Voltage Limits<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC<= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC0.85...1.1 Uc (-40-60 °C):operational AC/DC1...1.1 Uc (60-70 °C):operational AC/DC
    Irms Rated Making Capacity1000 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
    Maximum Operating Rate3600 cyc/h at 60 °C
    Minimum Switching Voltage17 V for signalling circuit

    Important Information Attributes

    Persona Type Ids
    EU, LC, OM, OM8, PB, SI
    Market Segmentation Id
    COMMERCIAL, INDUSTRIAL
    Associated Fuse Rating
    125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1
    Electrical Durability
    1.8 Mcycles 57 A AC-3 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 1.8 Mcycles 57 A AC-3e <= 440 V
    Mechanical Robustness
    vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    Mounting Support
    rail, plate
    Tightening Torque
    control circuit 1.7 N.m pozidriv No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mmpower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm, power circuit 5 N.m pozidriv No 2
    Control Circuit Voltage
    100...250 V
    [Ie] Rated Operational Current
    80 A (at <60 °C) at <= 440 V AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit
    Connections - Terminals
    control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solidpower circuit: 1 1-35 mm² - cable stiffness: flexible with cable end, power circuit: 1 1-35 mm² - cable stiffness: solidpower circuit: 2 1-25 mm² - cable stiffness: flexible without cable endpower circuit: 2 1-25 mm² - cable stiffness: flexible with cable end, power circuit: 2 1-25 mm² - cable stiffness: solidEverLink BTR screw connectorscontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solidpower circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible without cable end
    Carbon Footprint Of The Distribution Phase [A4]
    0.109522667437387, 0.1 kg CO2 eq.
    Carbon Footprint Of The Installation Phase [A5]
    0.1 kg CO2 eq., 0.0710443950672445
    Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
    47 kg CO2 eq., 47.47138804888935
    Local Publishable Date
    2026-06-27
    Stocking Flag
    N
    Device Type
    LV equipment - LV contactor
    Traceability
    No
    Average Life Duration
    20 year(s)
    Weee Product Category
    5
    Eoli Availability Display
    Yes
    Reach Full Compliance Status
    Reference contains Substances of Very High Concern above the threshold
    Reach Compliance Directive
    Reference contains Substances of Very High Concern above the threshold
    Rohs Eur Status
    Compliant By Exemption
    Rohs Eur Full Compliance Status
    Compliant By Exemption
    With Recycled Cardboard
    Yes
    Product Contributes To Saved And Avoided Emissions
    No
    Tier
    1
    Function Option
    Standard
    Average Impedance
    1.5 mOhm - Ith 80 A 50 Hz for power circuit
    Compatibility Code
    LC1D
    Fire Resistance
    850 °C IEC 60695-2-1
    Inrush Power In Va
    22-22 VA 50/60 Hz (at 20 °C)
    Mechanical Durability
    10 Mcycles
    Operating Time
    55...65 ms closing20...80 ms opening
    Pole Contact Composition
    3 NO
    Product Or Component Type
    contactor
    Returnability
    Yes
    Signalling Circuit Frequency
    25...400 Hz
    Sustainable Packaging
    Yes
    Weee Label
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Inf Motor Phase Current
    65 A
    Database Version
    2024-01
    Pcr Version
    PEP-PCR-ed4-2021 09 06
    Type Of Verification For The Pep
    Independent internal review
    Functional-unit Description
    Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    Functional-unit Unit
    unit
    Energy Model - Manufacturing [A1-a3]
    Electricity Mix; Low voltage; 2020; France, FR
    Energy Model - Use [B6]
    Electricity Mix; Low voltage; 2020; France, FR
    Recyclability Potential In %
    64
    Width Nominal
    55 mm
    [Ith] Conventional Free Air Thermal Current
    80 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
    [Ui] Rated Insulation Voltage
    power circuit 690 V IEC 60947-4-1signalling circuit 690 V IEC 60947-1
    Hold-in Power Consumption In Va
    2.1-2.1 VA 50/60 Hz (at 20 °C)
    Halogen-free Status
    Halogen free plastic parts and cables product
    Package Weight(Lbs)
    1.070 kg
    Warranty (In Months)
    18
    Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    Market SegmentationCommercial, Industrial
    Contactor Applicationmotor control, resistive load
    Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    Motor Power Kw30 kW at 380/400 V AC 50/60 Hz (AC-3e), 37 kW at 415 V AC 50/60 Hz (AC-3e), 37 kW at 440 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660/690 V AC 50/60 Hz (AC-3e), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3)30 kW at 380/400 V AC 50/60 Hz (AC-3)37 kW at 415 V AC 50/60 Hz (AC-3), 37 kW at 440 V AC 50/60 Hz (AC-3), 37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660/690 V AC 50/60 Hz (AC-3), 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 400 V AC 50/60 Hz (AC-4)
    Power Dissipation Per Pole9.6 W AC-16.3 W AC-3, 6.3 W AC-3e
    Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
    Certificate AgencyCCC, CSA, EAC, UL, KC, DNV-GL, LROS (Lloyds register of shipping), UKCA
    [Uc] Control Circuit Voltage100...250 V, 100...250 V AC 50/60 Hz, 100...250 V DC
    Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    Carbon Footprint Of The End-of-life Phase [C1 To C4]1.584597895220895, 2 kg CO2 eq.
    Carbon Footprint Of The Manufacturing Phase [A1 To A3]7 kg CO2 eq., 7.257806015568352
    Local Data StatusPublishable
    Return IndicatorY
    Stock Policy2
    ServiceabilityNo
    Field Service DivisionPPIBS
    Weee ScopeIn
    Scope PerimeterAt least in Europe
    End Of Life Doc RefENVEOLI1607010
    Reach Full Compliance Status IdCONTAINS_SVHC
    Rohs Eur In ScopeYes
    Rohs Eur Conformity Date1929
    China Rohs In ScopeNo
    Without Single Use PlasticYes
    Tier Id1
    Function Option IdSTANDARD
    Product Kit IdentifierN
    Coil Technologybuilt-in bidirectional peak limiting
    Device Short NameLC1D
    Heat Dissipation1.2-1.2 W at 50/60 Hz
    Inrush Power In W20-20 W 20 °C)
    Number Of Poles3P
    Overvoltage CategoryIII
    Product AvailabilityStock - Normally stocked in distribution facility
    Range Of ProductTeSys Deca Advanced
    Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    Software Versionv6.2.4
    Total Lifecycle Carbon Footprint56 kg CO2 eq.
    Connections TerminalsEverLink BTR screw connectors
    Pep CodeENVPEP1607010EN
    Pep Verification Date2025-11-20
    Psr VersionPSR-0005-ed3-2023 06 06
    Data Sourcereferent product
    Functional-unit Quantity1
    Reference Lifetime In Y20
    Energy Model - Installation [A5]No energy used
    Energy Model - End Of Life [C1-c4]Global, European and French datasets are used.
    Height Nominal122 mm
    [Icw] Rated Short-time Withstand Current110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit640 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
    [Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz
    [Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
    Hold-in Power Consumption In W1.2-1.2 W 20 °C
    Nbr. Of Units In Pkg.1
    Take-backNo
    Customs Code8536490065

    Environment Attributes Main

    China Rohs Regulation
    Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    Take Back
    No
    Recycled Metal Content At Cr Level
    0 %
    Carbon Footprint
    56.49435902218323
    Environmental Disclosure
    ENVPEP1607010EN
    Halogen Content Performance
    Halogen free plastic parts & cables product
    Operating Altitude
    0...9842.52 ft (0...3000 m)
    Packaging Without Single Use Plastic
    Yes
    Reach Regulation
    Reference contains Substances of Very High Concern above the threshold
    Pep Verification Date
    2025-11-20
    Psr Version
    PSR-0005-ed3-2023 06 06
    Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    Halogene PerformanceHalogen free plastic parts & cables product
    Mercury FreeYes
    Circularity ProfileENVEOLI1607010
    Eu Rohs DirectiveCompliant By Exemption
    Ip Degree Of ProtectionIP20 front face IEC 60529
    Packaging Made With Recycled CardboardYes
    Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
    Pep CodeENVPEP1607010EN
    Pcr VersionPEP-PCR-ed4-2021 09 06
    Type Of Verification For The PepIndependent internal review

    General Attributes

    Product Or Component Type
    contactor
    Range Of ProductTeSys Deca Advanced

    ETIM

    ETIM 8
    EC000066
    ETIM 9EC000066

    Contractual Warranty Attributes

    Warranty Period
    18 months
    Warranty18 months

    Accessories

    Loading carousel layout...

    Accessories

    Loading carousel layout...

    Similar Products

    Loading carousel layout...

    CAD$614.20/ EA

    Loading add to cart quantity...

    banner

    Need assistance?

    We can help! Connect with our Sales Team Today!