Schneider Electric

Schneider Electric LC1D80D7 TeSys Deca Contactor 3P 80A 42V AC Coil Screw Clamp Terminals

TeSys Deca Contactor 3P 80A 42V AC Coil Screw Clamp Terminals
  • MPN: LC1D80D7
  • PPN: SCH-LC1D80D7

Spec sheet

Loading compare button...

In Stock

Company Stock:

00

Lead times may vary. For an accurate estimate please contact us.

Loading dialog...

Looking to buy a large quantity?

To view product inventory

CAD$554.40/ EA

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 80A/1000V AC-3/AC-3e (37kW@400V). It provides a 42V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach).

Specifications

Environment

Product Certifications
RINA || LROS (Lloyds register of shipping) || GL || DNV || CSA || BV || UL || GOST || CCC
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Net Weight
1.59 kg
Protective Treatment
THIEC 60068-2-30
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Fire Resistance
850 °C IEC 60695-2-1
Depth
130 mm
Height127 mm
Climatic WithstandIACS E10 exposure to damp heat
Flame RetardanceV1 UL 94
Ip Degree Of ProtectionIP20 front face IEC 60529
Operating Altitude0...3000 m
Width85 mm
Permissible Ambient Air Temperature Around The Device-40-60 °C || 60-70 °C with derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP110205EN
Pvc Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity Profile
N/A
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach Free Of SvhcYes
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs DirectiveCompliant

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Power Dissipation Per Pole
5.1 W AC-3 || 12.5 W AC-1 || 5.1 W AC-3e
Auxiliary Contact Composition
1 NO + 1 NC
Control Circuit Voltage Limits
0.85...1.1 Uc -40-55 °C operational AC 60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55 °C operational AC 50 Hz || 1...1.1 Uc 55-70 °C operational AC 50/60 Hz
Contact Compatibility
M11
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance
> 10 MOhm for signalling circuit
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
Inrush Power In Va
245-245 VA 60 Hz cos phi 0.75 (at 20 °C) || 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
Pole Contact Composition
3 NO
Coil Technology
without built-in suppressor module
Minimum Switching Voltage
17 V for signalling circuit
Signalling Circuit Frequency
25...400 Hz
Electrical Durability
0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va
26-26 VA 60 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
Motor Power Hp
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors || 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors || 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
[Ui] Rated Insulation Voltage
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
Heat Dissipation
6-10 W at 50/60 Hz
Minimum Switching Current5 mA for signalling circuit
Average Impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit || 125 A (at 60 °C) for power circuit
Mounting Supportplate || rail
Control Circuit TypeAC 50/60 Hz
Pollution Degree3
Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
Connections - Terminalscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end || power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end || power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end || power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end || power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end || power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end || power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
Operating Time20...35 ms closing || 6...20 ms opening
Maximum Operating Rate3600 cyc/h 60 °C
Tightening Torquecontrol circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Mechanical Durability4 Mcycles
Compatibility CodeLC1D
Overvoltage CategoryIII
Motor Power Kw22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 45 kW at 415...440 V AC 50/60 Hz (AC-3) || 55 kW at 500 V AC 50/60 Hz (AC-3) || 45 kW at 660...690 V AC 50/60 Hz (AC-3) || 15 kW at 400 V AC 50/60 Hz (AC-4) || 22 kW at 220...230 V AC 50/60 Hz (AC-3e) || 37 kW at 380...400 V AC 50/60 Hz (AC-3e) || 45 kW at 415...440 V AC 50/60 Hz (AC-3e) || 55 kW at 500 V AC 50/60 Hz (AC-3e) || 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
[Icw] Rated Short-Time Withstand Current640 A 40 °C - 10 s for power circuit || 990 A 40 °C - 1 s for power circuit || 135 A 40 °C - 10 min for power circuit || 320 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Protective Coverwith

Specifications

[Uc] Control Circuit Voltage
42 V AC 50/60 Hz
Range Of Product
TeSys Deca
Product Or Component Type
contactor
Utilisation Category
AC-3 || AC-3e || AC-4 || AC-1
Poles Description
3P
[Ue] Rated Operational Voltagepower circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
Contactor Applicationmotor control || resistive load
RangeTeSys
[Ie] Rated Operational Current125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Device Short NameLC1D

Downloads

Similar Products

TeSys Deca Adapter Plate for GV2ME & LC1D09-D38, 0.04 kg

Schneider Electric LAD311 TeSys Deca Adapter Plate for GV2ME & LC1D09-D38, 0.04 kg

MPN

LAD311

In Stock

Company Stock:

00

CAD$29.35/EA
TeSys Deca Contactor 3P 150A 110V DC with Screw Clamp Terminals

Schneider Electric LC1D150FD TeSys Deca Contactor 3P 150A 110V DC with Screw Clamp Terminals

MPN

LC1D150FD

In Stock

Company Stock:

00

CAD$1242.83/EA
TeSys Deca Contactor 3P 50A 48V AC with Spring Terminals

Schneider Electric LC1D50A3E7 TeSys Deca Contactor 3P 50A 48V AC with Spring Terminals

MPN

LC1D50A3E7

In Stock

Company Stock:

00

CAD$422.80/EA
TeSys Deca Contactor, 4 Pole, 20A, 230V AC Coil, Compact Design

Schneider Electric LC1DT20P7 TeSys Deca Contactor, 4 Pole, 20A, 230V AC Coil, Compact Design

MPN

LC1DT20P7

In Stock

Company Stock:

00

CAD$187.65/EA
TeSys Deca Contactor 3P 50A 42V AC 50/60Hz, Compact 55mm

Schneider Electric LC1D50AD7 TeSys Deca Contactor 3P 50A 42V AC 50/60Hz, Compact 55mm

MPN

LC1D50AD7

In Stock

Company Stock:

00

CAD$402.71/EA
TeSys Deca Contactor 3P 150A 415V AC Coil IP20

Schneider Electric LC1D150N7 TeSys Deca Contactor 3P 150A 415V AC Coil IP20

MPN

LC1D150N7

In Stock

Company Stock:

00

CAD$1242.83/EA
TeSys Deca Contactor, 3P, 150A, 220V AC Coil, High Durability

Schneider Electric LC1D1506M7 TeSys Deca Contactor, 3P, 150A, 220V AC Coil, High Durability

MPN

LC1D1506M7

In Stock

Company Stock:

00

CAD$1380.52/EA
TeSys Deca Contactor, 3P, 115A, 48V DC Coil, Compact 120mm Width

Schneider Electric LC1D115ED TeSys Deca Contactor, 3P, 115A, 48V DC Coil, Compact 120mm Width

MPN

LC1D115ED

In Stock

Company Stock:

00

CAD$994.26/EA
TeSys Deca Contactor 3P 115A 110V DC Coil, IP20

Schneider Electric LC1D115FD TeSys Deca Contactor 3P 115A 110V DC Coil, IP20

MPN

LC1D115FD

In Stock

Company Stock:

00

CAD$994.26/EA
TeSys Deca Contactor 3P 50A 12V DC Coil Compact 55mm

Schneider Electric LC1D50AJD TeSys Deca Contactor 3P 50A 12V DC Coil Compact 55mm

MPN

LC1D50AJD

In Stock

Company Stock:

00

CAD$503.23/EA
TeSys Deca Contactor 3P 50A 48V DC Coil, IP20, 55mm Width

Schneider Electric LC1D50AED TeSys Deca Contactor 3P 50A 48V DC Coil, IP20, 55mm Width

MPN

LC1D50AED

In Stock

Company Stock:

00

CAD$503.23/EA
TeSys Deca Contactor 3P 50A 110V DC Coil 55mm Width

Schneider Electric LC1D50A3FD TeSys Deca Contactor 3P 50A 110V DC Coil 55mm Width

MPN

LC1D50A3FD

In Stock

Company Stock:

00

CAD$528.20/EA

You might also be interested in

Loading carousel layout...

Others Also Viewed

Loading carousel layout...

CAD$554.40/ EA

Loading add to cart quantity...

banner

Need assistance finding the right item?

We can help! Connect with our Sales Team Today!