TeSys Deca 3-Phase Contactor 80A AC-3 24V 50Hz with 1NO+1NC Contacts
TeSys Deca 3-Phase Contactor 80A AC-3 24V 50Hz with 1NO+1NC Contacts
Schneider Electric

Schneider Electric LC1D80B5 TeSys Deca 3-Phase Contactor 80A AC-3 24V 50Hz with 1NO+1NC Contacts

  • MPN: LC1D80B5
  • PPN: SCH-LC1D80B5

CAD

$587.72

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys Deca 3-Phase Contactor 80A AC-3 24V 50Hz with 1NO+1NC Contacts

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Czechia
Depth130 mm

Complementary Attributes

Control Circuit Type
AC 50 Hz, AC 50 Hz
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1100 A at 440 V for power circuit conforming to IEC 60947
Maximum Motor Phase Current
80 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50 Hz, 0.85...1.1 Uc (-40-55 °C):operational AC 50 Hz, 1...1.1 Uc (55-70 °C):operational AC 50 Hz
Maximum Horse Power Rating30 hp at 230/240 V AC 50/60 Hz for 3 phase motors7.5 hp at 120 V AC 50/60 Hz for 1 phase motors, 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 60 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
1.5 Mcycles 80 A AC-3 <= 440 V, 0.8 Mcycles 125 A AC-1 <= 440 V, 1.5 Mcycles 80 A AC-3e <= 440 V
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz), shocks contactor open 8 Gn for 11 ms), vibrations contactor closed 3 Gn, 5...300 Hz), shocks contactor closed 10 Gn for 11 ms)
Mounting Support
rail, plate
Power Dissipation Per Pole
5.1 W AC-3, 12.5 W AC-1, 5.1 W AC-3e
Tightening Torque
power circuit 12 N.m connector flat Ø 6 to Ø 8 mm, power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.2 N.m screw clamp terminals Philips No 2, control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Certificate Agency
CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
[Ie] Rated Operational Current
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control Circuit Voltage
24 V, 24 V AC 50 Hz
[Ui] Rated Insulation Voltage
signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 1000 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1
Non-overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]
4.088997647987764, 4 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
11 kg CO2 eq., 10.960713361237987
Local Data Status
Publishable
Return Indicator
N
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
Reach Full Compliance Status
Free of Substances of Very High Concern above the threshold
Reach Compliance Directive
Free of Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant
Rohs Eur Full Compliance Status
Compliant
China Rohs Label
1
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Coil Technology
without built-in suppressor module
Contact Compatibility
M12
Fire Resistance
850 °C IEC 60695-2-1
Heat Dissipation
6-10 W at 50 Hz
Mechanical Durability
10 Mcycles
Overvoltage Category
III
Product Availability
Non-Stock - Not normally stocked in distribution facility
Protective Treatment
THIEC 60068-2-30
Range Of Product
TeSys Deca
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage
24 V
Pep Code
ENVPEP1102005EN
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime, In Y
20
Energy Model - Manufacturing [A1-a3]
Electricity Mix; Production mix; Low voltage; CZ
Energy Model - Use [B6]
Electricity Mix; Production mix; Low voltage; FR
Recyclability Potential, In %
76
Width Nominal
85 mm
Hold-in Power Consumption In Va
20-20 VA 50 Hz cos phi 0.3 (at 20 °C)
Package Weight(Lbs)
1.56 kg
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw37 kW at 380...400 V AC 50 Hz (AC-3e), 45 kW at 415...440 V AC 50 Hz (AC-3e), 55 kW at 500 V AC 50 Hz (AC-3e), 45 kW at 660...690 V AC 50 Hz (AC-3e)22 kW at 220...230 V AC 50 Hz (AC-3), 37 kW at 380...400 V AC 50 Hz (AC-3), 45 kW at 415...440 V AC 50 Hz (AC-3), 55 kW at 500 V AC 50 Hz (AC-3), 45 kW at 660...690 V AC 50 Hz (AC-3), 15 kW at 400 V AC 50 Hz (AC-4), 22 kW at 220...230 V AC 50 Hz (AC-3e)
Operating Time20...35 ms closing, 6...20 ms opening
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
[Icw] Rated Short-time Withstand Current135 A 40 °C - 10 min for power circuit, 320 A 40 °C - 1 min for power circuit, 640 A 40 °C - 10 s for power circuit, 990 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Connections - Terminalscontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end, screw clamp terminals, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.21622581342878092, 0.2 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0.3 kg CO2 eq., 0.31002666931072853
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]81 kg CO2 eq., 81.20896739130431
Local Publishable Date2025-02-26
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayNo need of specific recycling operations
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date1924
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Average Impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Flame RetardanceV1 conforming to UL 94
Inrush Power In Va200-200 VA 50 Hz cos phi 0.75 (at 20 °C)
Number Of Poles3P
Pole Contact Composition3 NO
Product Or Component Typecontactor
RangeTeSys
ReturnabilityNo
Software Versionv5.9.4
Total Lifecycle Carbon Footprint97 kg CO2 eq.
Connections Terminalsscrew clamp terminals
Inf Motor Phase Current80 A
Database Version2022-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionSwitch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
Functional-unit Unitunit
Energy Consumption On Product Lifetime, In Kwh1215.45
Energy Model - Installation [A5]Electricity Mix; Production mix; Low voltage; FR
Energy Model - End Of Life [C1-c4]Electricity Mix; Production mix; Low voltage; FR
Height Nominal127 mm
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
Nbr. Of Units In Pkg.1
Take-backNo

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take Back
No
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Climatic Withstand
IACS E10 exposure to damp heat
Eu Rohs Directive
Compliant
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed2-2016 03 29
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C, 60-70 °C with derating
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint96.78493088326958
Environmental DisclosureENVPEP1102005EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP1102005EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$587.72/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])