Description
Specifications
Environment
- Mechanical Robustness
- vibrations class 2) IEC 60255-21-1 || shocks class 2) IEC 60255-21-2 || earthquakes class 2) IEC 60255-21-3 || vibrations GOST 17516.1
- Environmental Characteristic
- exposure to cold IEC 60068-2-1 || exposure to dry heat IEC 60068-2-2 || exposure to damp heat in service IEC 60068-2-78 || exposure to damp heat in service IEC 60068-2-30 || temperature variation IEC 60068-2-14 || salt mist IEC 60068-2-52 || influence of corrosion/gas test 2 IEC 60068-2-60 || influence of corrosion/gas test 4 IEC 60068-2-60 || stationary use at weatherprotected locations IEC 60721-3-3
- Relative Humidity
- 0-93 % at 40-40 °C, without condensation, 56 days || 93-95 % at 25-55 °C, 6 cycles, 12 + 12 hours
- Operating Altitude
- 2000 m
Contractual warranty
- Warranty
- up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions))
Offer Sustainability
- Environmental Disclosure
- ENVPEP1901010
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
- Circularity Profile
- ENVEOLI1901010
Complementary
- Number Of Key
- 7 customizable
- Depth
- 219 mm
- Height
- 176 mm
- Net Weight
- 3.5 kg
Specifications
- Analogue Output Number
- 0
- Range Of Product
- PowerLogic P5
- Network And Machine Diagnosis Type
- event recording || disturbance recording || trip context information || relay maintenance
- Number Of Outputs
- 15 digital || 1 watchdog
- Protection Type
- phase overcurrent 50/51 || directional phase overcurrent 67 || earth fault overcurrent 50N/51N || directional earth fault 67N || transient earth fault 67NI || neutral admittance 21YN || earth fault wattmetric 32N || restricted earth fault 64REF || capacitor bank unbalance 51C || current unbalance 46 I2/I1 || broken conductor || cold load pick-up || switch ON to fault (SOTF) || H2 detection || H5 detection || breaker failure 50BF || directional active underpower 37P || fault locator 21FL || recloser 79 || negative sequence overcurrent 46 || overvoltage 59 || undervoltage 27 || earth fault overvoltage 59N || underfrequency 81/81N || rate of change of frequency 81R || synchro-check 25 || lockout relay 86 || CT supervision 60 || VT supervision 60 || programmable stages 99 || programmable logic || programmable curve
- Communication Port Protocol
- without
- Single Line Diagram
- 6 controlled + 2 monitored objects
- Monitoring Function
- trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring
- Control Type
- switchgear control and monitoring || programmable switchgear interlocking || local/remote control || advanced logic engine
- Integrated Connection Type
- front USB 2.0 type A 2 || rear extension port 1 with backup memory
- Arc Flash Protection
- no
- Device Short Name
- P5F30-EECE-GAAAH-AADK