TeSys D Control Relay, 3NO+2NC, 120V AC, 10A, Compact 45mm Width
Schneider Electric

Schneider Electric CAD32G7TQ TeSys D Control Relay, 3NO+2NC, 120V AC, 10A, Compact 45mm Width

  • MPN: CAD32G7TQ
  • PPN: SCH-CAD32G7TQ

CAD

$113.03

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 120V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
France
Depth86 mm

Complementary Attributes

Control Circuit Voltage Limits
drop-out: 0.3...0.6 Uc, operational: 0.8...1.1 Uc at 50 Hzoperational: 0.85...1.1 Uc at 60 Hz
Irms Rated Making Capacity
140 A <= 690 V AC IEC 60947-5-1
Minimum Switching Current
5 mA
Control Circuit TypeAC
Maximum Operating Rate3 cyc/s 20 °C
Minimum Switching Voltage17 V

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB
Insulation Resistance
> 10 MOhm, > 10 MOhm
Range
TeSys, TeSys Deca
Utilisation Category
AC-14, AC-15
[Ue] Rated Operational Voltage
<= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz<= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz, <= 690 V AC 25...400 Hz
Connections - Terminals
2 x 1-4 mm²flexible without cable end, 1 x 1-4 mm²flexible with cable end, 1 x 1-4 mm²flexible without cable end, 1 x 1-4 mm²solid without cable end, 2 x 1-2.5 mm²flexible with cable end
Carbon Footprint Of The Distribution Phase [A4]
0.2688271654154445, 0.3 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
2 kg CO2 eq., 2.4052974453589133
Local Data Status
Publishable
Return Indicator
Y
Stock Policy
1
Serviceability
No
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1501004
Reach Full Compliance Status Id
CONTAINS_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Full Compliance Status
Compliant By Exemption
China Rohs Label
3
Without Single Use Plastic
Yes
Tier Id
2
Function Option Id
STANDARD
Market Segmentation Id
INDUSTRIAL
Product Kit Identifier
N
Coil Type
standard
Contact Operation
mechanically linked IEC 60947-5-1
Device Short Name
CAD
Operating Time
12...22 ms coil energisation and NO closing4...12 ms coil de-energisation and NO opening4...19 ms coil energisation and NC opening6...17 ms coil de-energisation and NC closing
Product Availability
Stock - Normally stocked in distribution facility
Protective Treatment
TH IEC 60068
Returnability
Yes
Software Version
v6.2.4
Sustainable Packaging
Yes
Total Lifecycle Carbon Footprint
18 kg CO2 eq.
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage 4
120 V AC 50/60 Hz
Database Version
2024-01
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Functional-unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unit
unit
Energy Consumption On Product Lifetime In Kwh
170.82
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
77 mm
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Nbr. Of Units In Pkg.
1
Take-back
No
Customs Code
8536490065
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Product NameTeSys CAD, TeSys Deca
Range Of Productcontrol relay, TeSys Deca
Certificate AgencyCSA, UL, UKCA
[Ui] Rated Insulation Voltage600 VCSA, 600 VUL690 V III 3) IEC 60947-5-1
Non-overlap Time1.5 ms on de-energisation between NC and NO contacts, 1.5 ms on energisation between NC and NO contacts
Carbon Footprint Of The Installation Phase [A5]0.1 kg CO2 eq., 0.09473546449819852
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]15 kg CO2 eq., 15.364183683872902
Local Publishable Date2026-06-27
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusReference contains Substances of Very High Concern above the threshold
Reach Compliance DirectiveReference contains Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant By Exemption
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier2
Function OptionStandard
Market SegmentationIndustrial
Associated Fuse Rating10 A gG <= 690 V IEC 60947-5-1
Compatibility CodeCAD
Contactor Applicationcontrol circuit
Inrush Power In Va70-70 VA (at 20 °C)
Pole Contact Composition3 NO + 2 NC
Product Or Component Typeauxiliary contactor
Quantity Per Setset of 10
Shock Resistance10 gn control relay open15 gn control relay closed
Suppressor Technologywithout built-in
Tightening Torque1.7-1.7 N.m
Vibration Resistance2 gn 5-300 Hz control relay open4 gn 5-300 Hz control relay closed
Pole Contact Comp3 NO + 2 NC
Pep CodeENVPEP1501004EN
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %66
Width Nominal45 mm
[Uc] Control Circuit Voltage120 V AC 50/60 Hz
Hold-in Power Consumption In Va8-8 VA 50 Hz (at 20 °C)
Package Weight(Lbs)317.514 g
Warranty (In Months)18

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage
-60-80 °C, -60-80 °C
Recycled Metal Content At Cr Level
0 %
Carbon Footprint
18.13304375914546
Environmental Disclosure
ENVPEP1501004EN
Ip Degree Of Protection
IP2X conforming to VDE 0106
Packaging Made With Recycled Cardboard
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Pep Verification Date
2026-03-17
Psr Version
PSR-0005-ed3-2023 06 06
Ambient Air Temperature For Operation-40-70 °C at Uc, -40-70 °C at Uc, -5-60 °C at 0.8...1.1 Uc, -5-60 °C at 0.8...1.1 Uc-40-70 °C at Uc, -40-70 °C at Uc, -5-60 °C at 0.8...1.1 Uc, -5-60 °C at 0.8...1.1 Uc
Take BackNo
Mercury FreeYes
Circularity ProfileENVEOLI1501004
Eu Rohs DirectiveCompliant By Exemption
Operating Altitude9842.52 ft (3000 m) without derating
Packaging Without Single Use PlasticYes
Pep CodeENVPEP1501004EN
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Range Of Product
control relay, TeSys Deca
Product Or Component Typeauxiliary contactor

ETIM

ETIM 8
EC000196
ETIM 9EC000196

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$113.03/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!