TeSys Deca Contactor 3P 12A 220V AC 50/60Hz Coil IP20 45mm Width
TeSys Deca Contactor 3P 12A 220V AC 50/60Hz Coil IP20 45mm Width
TeSys Deca Contactor 3P 12A 220V AC 50/60Hz Coil IP20 45mm Width
TeSys Deca Contactor 3P 12A 220V AC 50/60Hz Coil IP20 45mm Width
Schneider Electric

Schneider Electric LC1D12M7 TeSys Deca Contactor 3P 12A 220V AC 50/60Hz Coil IP20 45mm Width

  • MPN: LC1D12M7
  • PPN: SCH-LC1D12M7

CAD

$207.97

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (5.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Features

  • Engineered for demanding inductive loads, this 3-pole contactor supports up to 12 Amps (AC-3) or 25 Amps (AC-1) at voltages up to 690V AC. It comfortably manages 3-phase motors up to 5.5 kW (7.5 hp) at 380 400V, providing commercial electricians and machine builders with a robust, reliable solution for conveyor belts, fans, and packaging machinery.
  • Operating on a highly standard 220V AC control voltage compatible with both 50Hz and 60Hz frequencies, the M7 coil voltage code integrates into existing motor control centers. This eliminates the need for external step-down control transformers, minimizing cabinet costs and simplifying retrofits in standard industrial panels.
  • Outfitted out of the box with one normally open and one normally closed auxiliary contact, this unit simplifies control circuit engineering. It allows panel builders to immediately wire up remote status indicators, safety interlocks, or PLC feedback loops, saving valuable DIN rail space and lowering overall component expenses.
  • Featuring patented EverLink creep-mitigation technology, the terminal blocks maintain consistent pressure on stranded or solid copper wires even as the metal expands and contracts under heavy load. This architecture prevents localized resistance spikes and dangerous arcing, drastically reducing routine torque maintenance schedules for industrial maintenance crews.
  • Part of the highly modular TeSys Deca ecosystem, the LC1D12M7 accepts a massive array of clip-on accessories including LAD pneumatic timer blocks, mechanical latching blocks, and side-mounted auxiliary modules. Additionally, it features direct plug-in compatibility with LRD thermal overload relays, allowing technicians to build a complete, space-saving motor starter assembly in seconds.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia, Singapore
Depth86 mm

Complementary Attributes

Control Circuit Voltage Limits
0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating
3 hp at 230/240 V AC 50/60 Hz for 3 phase motors0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors10 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Maximum Motor Phase Current
12 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Control Circuit TypeAC 50/60 Hz standard
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Contactor Application
resistive load, motor control
Inrush Power In Va
70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
Mounting Support
rail, plate
Tightening Torque
control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Control Circuit Voltage
220 V
[Ie] Rated Operational Current
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ui] Rated Insulation Voltage
signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1
Non-overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The Installation Phase [A5]
0.1 kg CO2 eq., 0.05308452752054227
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
22 kg CO2 eq., 21.825019899655352
Local Publishable Date
2026-07-07
Stocking Flag
N
Device Type
LV equipment - LV contactor
Traceability
No
Average Life Duration
20 year(s)
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI1501004
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
2538
China Rohs In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit25 A gG at <= 690 V coordination type 2 for power circuit
Coil Technology
without built-in suppressor module
Contact Compatibility
M2
Fire Resistance
850 °C IEC 60695-2-1
Heat Dissipation
2-3 W at 50/60 Hz
Number Of Poles
3P
Overvoltage Category
III
Product Availability
Stock - Normally stocked in distribution facility
Protective Treatment
THIEC 60068-2-30
Returnability
Yes
Signalling Circuit Frequency
25...400 Hz
Sustainable Packaging
Yes
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep Code
ENVPEP1501004EN
Pep Verification Date
2026-03-17
Psr Version
PSR-0005-ed3-2023 06 06
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Installation [A5]
No energy used
Energy Model - End Of Life [C1-c4]
Global, European and French datasets are used.
Height Nominal
77 mm
[Icw] Rated Short-time Withstand Current
105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC
Hold-in Power Consumption In Va
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Package Weight(Lbs)
360.000 g
Warranty (In Months)
18
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Electrical Durability2 Mcycles 12 A AC-3 <= 440 V, 0.8 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 12 A AC-3e <= 440 V
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw5.5 kW at 380/400 V AC 50/60 Hz (AC-3e), 5.5 kW at 415/440 V AC 50/60 Hz (AC-3e), 7.5 kW at 500 V AC 50/60 Hz (AC-3e), 7.5 kW at 660/690 V AC 50/60 Hz (AC-3e), 3 kW at 220/230 V AC 50/60 Hz (AC-3)5.5 kW at 380/400 V AC 50/60 Hz (AC-3), 5.5 kW at 415/440 V AC 50/60 Hz (AC-3)7.5 kW at 500 V AC 50/60 Hz (AC-3), 7.5 kW at 660/690 V AC 50/60 Hz (AC-3), 3 kW at 220/230 V AC 50/60 Hz (AC-3e), 3.7 kW at 400 V AC 50/60 Hz (AC-4)
Power Dissipation Per Pole0.36 W AC-31.56 W AC-1, 0.36 W AC-3e
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
Certificate AgencyUL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
[Uc] Control Circuit Voltage220 V, 220 V AC 50/60 Hz
Connections - Terminalspower circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endscrew clamp terminalspower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
Carbon Footprint Of The Distribution Phase [A4]0.15063591165520598, 0.2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]1 kg CO2 eq., 1.3477959823131842
Local Data StatusPublishable
Return IndicatorY
Stock Policy2
ServiceabilityNo
Field Service DivisionPPIBS
Service Catalog ItemFinished good
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Compatibility CodeLC1D
Device Short NameLC1D
Flame RetardanceV1 conforming to UL 94
Mechanical Durability15 Mcycles
Operating Time12...22 ms closing4...19 ms opening
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys Deca
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Software Versionv6.2.4
Total Lifecycle Carbon Footprint23 kg CO2 eq.
Inf Motor Phase Current12 A
Database Version2024-01
Pcr VersionPEP-PCR-ed4-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Model - Manufacturing [A1-a3]Electricity Mix; Low voltage; 2020; France, FR
Energy Model - Use [B6]Electricity Mix; Low voltage; 2020; France, FR
Recyclability Potential In %66
Width Nominal45 mm
[Ith] Conventional Free Air Thermal Current25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490065

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Take Back
No
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Circularity Profile
ENVEOLI1501004
Eu Rohs Directive
Compliant
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Free Of Svhc
Yes
Pep Code
ENVPEP1501004EN
Pcr Version
PEP-PCR-ed4-2021 09 06
Type Of Verification For The Pep
Independent internal review
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint23.376536321144286
Environmental DisclosureENVPEP1501004EN
Ip Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Permissible Ambient Air Temperature Around The Device-40-60 °C-40-60 °C60-70 °C with derating
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2026-03-17
Psr VersionPSR-0005-ed3-2023 06 06

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months
Loading video…

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$207.97/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!