- Engineered for demanding inductive loads, this 3-pole contactor supports up to 12 Amps (AC-3) or 25 Amps (AC-1) at voltages up to 690V AC. It comfortably manages 3-phase motors up to 5.5 kW (7.5 hp) at 380 400V, providing commercial electricians and machine builders with a robust, reliable solution for conveyor belts, fans, and packaging machinery.
- Operating on a highly standard 220V AC control voltage compatible with both 50Hz and 60Hz frequencies, the M7 coil voltage code integrates into existing motor control centers. This eliminates the need for external step-down control transformers, minimizing cabinet costs and simplifying retrofits in standard industrial panels.
- Outfitted out of the box with one normally open and one normally closed auxiliary contact, this unit simplifies control circuit engineering. It allows panel builders to immediately wire up remote status indicators, safety interlocks, or PLC feedback loops, saving valuable DIN rail space and lowering overall component expenses.
- Featuring patented EverLink creep-mitigation technology, the terminal blocks maintain consistent pressure on stranded or solid copper wires even as the metal expands and contracts under heavy load. This architecture prevents localized resistance spikes and dangerous arcing, drastically reducing routine torque maintenance schedules for industrial maintenance crews.
- Part of the highly modular TeSys Deca ecosystem, the LC1D12M7 accepts a massive array of clip-on accessories including LAD pneumatic timer blocks, mechanical latching blocks, and side-mounted auxiliary modules. Additionally, it features direct plug-in compatibility with LRD thermal overload relays, allowing technicians to build a complete, space-saving motor starter assembly in seconds.
Documentation & Downloads
Specifications
Key Specifications
| Country of Origin | Brazil, France, Indonesia, Singapore |
|---|
| Depth | 86 mm |
|---|
Complementary Attributes
| Control Circuit Voltage Limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
|---|---|
| Maximum Horse Power Rating | 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors10 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Maximum Motor Phase Current | 12 A |
| Minimum Switching Current | 5 mA for signalling circuit |
| Rated Breaking Capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| Irms Rated Making Capacity | 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
|---|---|
| Control Circuit Type | AC 50/60 Hz standard |
| Maximum Operating Rate | 3600 cyc/h at 60 °C |
| Minimum Switching Voltage | 17 V for signalling circuit |
Important Information Attributes
| Persona Type Ids | EU, LC, OM, OM8, PB, SI |
|---|---|
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Contactor Application | resistive load, motor control |
| Inrush Power In Va | 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms) |
| Mounting Support | rail, plate |
| Tightening Torque | control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2 |
| Control Circuit Voltage | 220 V |
| [Ie] Rated Operational Current | 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Ui] Rated Insulation Voltage | signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 690 V IEC 60947-4-1power circuit 600 V CSA, power circuit 600 V ULsignalling circuit 690 V IEC 60947-1 |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact |
| Carbon Footprint Of The Installation Phase [A5] | 0.1 kg CO2 eq., 0.05308452752054227 |
| Carbon Footprint Of The Use Phase [B2 B3 B4 B6] | 22 kg CO2 eq., 21.825019899655352 |
| Local Publishable Date | 2026-07-07 |
| Stocking Flag | N |
| Device Type | LV equipment - LV contactor |
| Traceability | No |
| Average Life Duration | 20 year(s) |
| Weee Scope | In |
| Scope Perimeter | At least in Europe |
| End Of Life Doc Ref | ENVEOLI1501004 |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Rohs Eur In Scope | Yes |
| Rohs Eur Conformity Date | 2538 |
| China Rohs In Scope | No |
| With Recycled Cardboard | Yes |
| Product Contributes To Saved And Avoided Emissions | No |
| Tier | 1 |
| Function Option | Standard |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit25 A gG at <= 690 V coordination type 2 for power circuit |
| Coil Technology | without built-in suppressor module |
| Contact Compatibility | M2 |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Heat Dissipation | 2-3 W at 50/60 Hz |
| Number Of Poles | 3P |
| Overvoltage Category | III |
| Product Availability | Stock - Normally stocked in distribution facility |
| Protective Treatment | THIEC 60068-2-30 |
| Returnability | Yes |
| Signalling Circuit Frequency | 25...400 Hz |
| Sustainable Packaging | Yes |
| Weee Label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Pep Code | ENVPEP1501004EN |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
| Data Source | extrapolated product |
| Functional-unit Quantity | 1 |
| Reference Lifetime In Y | 20 |
| Energy Model - Installation [A5] | No energy used |
| Energy Model - End Of Life [C1-c4] | Global, European and French datasets are used. |
| Height Nominal | 77 mm |
| [Icw] Rated Short-time Withstand Current | 105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hzpower circuit <= 300 V DC |
| Hold-in Power Consumption In Va | 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Package Weight(Lbs) | 360.000 g |
| Warranty (In Months) | 18 |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator |
|---|---|
| Market Segmentation | Commercial, Industrial |
| Electrical Durability | 2 Mcycles 12 A AC-3 <= 440 V, 0.8 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 12 A AC-3e <= 440 V |
| Insulation Resistance | > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit |
| Motor Power Kw | 5.5 kW at 380/400 V AC 50/60 Hz (AC-3e), 5.5 kW at 415/440 V AC 50/60 Hz (AC-3e), 7.5 kW at 500 V AC 50/60 Hz (AC-3e), 7.5 kW at 660/690 V AC 50/60 Hz (AC-3e), 3 kW at 220/230 V AC 50/60 Hz (AC-3)5.5 kW at 380/400 V AC 50/60 Hz (AC-3), 5.5 kW at 415/440 V AC 50/60 Hz (AC-3)7.5 kW at 500 V AC 50/60 Hz (AC-3), 7.5 kW at 660/690 V AC 50/60 Hz (AC-3), 3 kW at 220/230 V AC 50/60 Hz (AC-3e), 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
| Power Dissipation Per Pole | 0.36 W AC-31.56 W AC-1, 0.36 W AC-3e |
| Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
| Certificate Agency | UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme |
| [Uc] Control Circuit Voltage | 220 V, 220 V AC 50/60 Hz |
| Connections - Terminals | power circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endpower circuit: 2 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: 1 1-4 mm² - cable stiffness: flexible with cable endcontrol circuit: 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: 2 1-4 mm² - cable stiffness: solid without cable endscrew clamp terminalspower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end |
| Carbon Footprint Of The Distribution Phase [A4] | 0.15063591165520598, 0.2 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase [A1 To A3] | 1 kg CO2 eq., 1.3477959823131842 |
| Local Data Status | Publishable |
| Return Indicator | Y |
| Stock Policy | 2 |
| Serviceability | No |
| Field Service Division | PPIBS |
| Service Catalog Item | Finished good |
| Weee Product Category | 5 |
| Eoli Availability Display | Yes |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur Status | Compliant |
| Rohs Eur Full Compliance Status | Compliant |
| China Rohs Label | 1 |
| Without Single Use Plastic | Yes |
| Tier Id | 1 |
| Function Option Id | STANDARD |
| Product Kit Identifier | N |
| Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Compatibility Code | LC1D |
| Device Short Name | LC1D |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Durability | 15 Mcycles |
| Operating Time | 12...22 ms closing4...19 ms opening |
| Pole Contact Composition | 3 NO |
| Product Or Component Type | contactor |
| Range Of Product | TeSys Deca |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Software Version | v6.2.4 |
| Total Lifecycle Carbon Footprint | 23 kg CO2 eq. |
| Inf Motor Phase Current | 12 A |
| Database Version | 2024-01 |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Functional-unit Description | Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years |
| Functional-unit Unit | unit |
| Energy Model - Manufacturing [A1-a3] | Electricity Mix; Low voltage; 2020; France, FR |
| Energy Model - Use [B6] | Electricity Mix; Low voltage; 2020; France, FR |
| Recyclability Potential In % | 66 |
| Width Nominal | 45 mm |
| [Ith] Conventional Free Air Thermal Current | 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Nbr. Of Units In Pkg. | 1 |
| Take-back | No |
| Customs Code | 8536490065 |
Environment Attributes Main
| China Rohs Regulation | Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope) |
|---|---|
| Take Back | No |
| Recycled Metal Content At Cr Level | 0 % |
| Mercury Free | Yes |
| Circularity Profile | ENVEOLI1501004 |
| Eu Rohs Directive | Compliant |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Packaging Without Single Use Plastic | Yes |
| Reach Free Of Svhc | Yes |
| Pep Code | ENVPEP1501004EN |
| Pcr Version | PEP-PCR-ed4-2021 09 06 |
| Type Of Verification For The Pep | Independent internal review |
| Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
|---|---|
| Reach Free Shvc | Yes |
| Toxic Heavy Metal Free | Yes |
| Carbon Footprint | 23.376536321144286 |
| Environmental Disclosure | ENVPEP1501004EN |
| Ip Degree Of Protection | IP20 front face IEC 60529 |
| Packaging Made With Recycled Cardboard | Yes |
| Permissible Ambient Air Temperature Around The Device | -40-60 °C-40-60 °C60-70 °C with derating |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Pep Verification Date | 2026-03-17 |
| Psr Version | PSR-0005-ed3-2023 06 06 |
General Attributes
| Product Or Component Type | contactor |
|---|
| Range Of Product | TeSys Deca |
|---|
ETIM
| ETIM 8 | EC000066 |
|---|
| ETIM 9 | EC000066 |
|---|
Contractual Warranty Attributes
| Warranty Period | 18 months |
|---|
| Warranty | 18 months |
|---|




Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$207.97
/ EA
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Spec sheet
CAD$207.97/ EA
Loading add to cart quantity...