TeSys Deca Contactor 3P 150A 120V AC Coil, IP20
Schneider Electric

Schneider Electric LC1D150G7 TeSys Deca Contactor 3P 150A 120V AC Coil, IP20

  • MPN: LC1D150G7
  • PPN: SCH-LC1D150G7
  • If you can't find the product or are unsure which one you need, please use the Product Selector tool below
  • CAD

    $1317.52

    / EA

    Available to Order

    Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST

    Company Stock:

    0

    Loading dialog...

    Looking to buy a large quantity?

    To view product inventory

    Spec sheet

    Description

    TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 150A/1000V AC-3 (75kW@400V). It provides a 120V 50/60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirrror contact), power connection by screw connectors 2 inputs, control connection by screw clamp terminals. For operating rates until 1200 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

    Features

    • This heavy-duty 3-pole contactor is a core component of the Schneider Electric TeSys D range, engineered for seamless mechanical and electrical synchronization with LRD overload relays and GV3 manual starters. Utilizing a standardized modular architecture allows industrial engineers to reduce panel assembly time and simplify complex wiring layouts in high-performance motor control centers.
    • Equipped with a versatile "G7" code coil, this device operates reliably on 120V AC control power, the most common standard for industrial automation in North America. The high-performance electromagnetic coil ensures rapid, consistent contact engagement, preventing chatter and reducing internal heat buildup to extend the operational lifespan of your critical power switching equipment.
    • Rated for 150 Amps in AC-3 applications, this contactor is built to manage the demanding starting and stopping cycles of 3-phase motors up to 75kW at 400/440V (or approximately 100HP at 480V). The robust silver-alloy power contacts are designed to withstand high-current inrush without welding, ensuring long-term reliability for heavy-duty pumps, fans, and compressors in manufacturing environments.
    • Standardized with one normally open (1 NO) and one normally closed (1 NC) built-in auxiliary contact, this unit provides immediate feedback to your logic controllers or status indicator lights. This eliminates the need for expensive add-on blocks for basic signaling, allowing for real-time monitoring of "run" or "fault" states and improving the overall safety and transparency of your automated processes.

    Documentation & Downloads

    Specifications

    Additional

    Rated Operational Current
    200 A AC-1, 150 A AC-3, 150 A AC-3e at <= 440 V AC (at <60 °C) power circuit
    Utilisation Category
    AC-3, AC-1, AC-4, AC-3e
    Maximum Horse Power
    40 hp at 200/208 V, 50 hp at 230/240 V, 100 hp at 460/480 V, 125 hp at 575/600 V AC 50/60 Hz, 3 phase
    Making Capacity
    1660 A at 440 V AC
    Short-Time Withstand Current
    250 A 10 min, 580 A 1 min, 1200 A 10 s, 1400 A 1 s (at 104°F/40°C) power circuit
    Average Impedance
    0.6 mOhm at 200 A 50 Hz power circuit
    Rated Insulation Voltage
    600 V CSA/UL power circuit, 1000 V IEC, 690 V signaling circuit
    Pollution Degree
    3
    Mechanical Durability
    8 million cycles
    Coil Technology
    Built-in bidirectional peak limiting diode suppressor
    Inrush Power
    280-350 VA 50/60 Hz cos phi 0.9 (at 20 °C)
    Heat Dissipation
    3-4.5 W at 50/60 Hz
    Maximum Operating Rate
    1200 cycles/hour at 140°F (60°C)
    Tightening Torque
    1.2 N·m control circuit, 12 N·m power circuit
    IP Degree of Protection
    IP20 front face IEC 60529
    Operating Altitude
    0 to 3000 m (9842 ft)
    Net Weight
    2.5 kg (5.51 lb)
    Flame Retardance
    V1 UL 94
    Compliance
    IEC 60947-4-1, IEC 60947-5-1, UL 508, CSA C22.2 No 14, CCC, EAC, Marine, GOST, RINA, DNV, GL, UKCA, CE, RoHS, REACh
    Sustainable Status
    Green Premium
    Warranty
    18 months
    Rated Breaking Capacity1400 A at 440 V AC power circuit
    Motor Power40 kW at 220-230 V, 75 kW at 380-400 V, 80 kW at 415-440 V, 90 kW at 500 V, 100 kW at 660-690 V, 75 kW at 1000 V AC-3
    Thermal Current200 A at 140°F (60°C)
    Breaking Capacity1400 A at 440 V AC
    Associated Fuse Rating315 A gG type 1, 250 A gG type 2 at <= 690 V
    Power Dissipation per Pole24 W AC-1, 13.5 W AC-3, 13.5 W AC-3e
    Overvoltage CategoryIII
    Impulse Withstand Voltage8 kV IEC 60947
    Electrical Durability0.85 million cycles AC-3 150 A 440 V, 1 million cycles AC-1 200 A 440 V, 0.85 million cycles AC-3e 150 A 440 V
    Control Circuit Voltage Limits0.3...0.5 Uc drop-out, 0.8...1.15 Uc operational, -40 to 70 °C
    Hold-in Power2-18 VA 50/60 Hz cos phi 0.9 (at 20 °C)
    Operating Time20-35 ms closing, 40-75 ms opening
    Connection TerminalsScrew clamp terminals (1-2.5 mm²) control circuit, screw connectors (10-120 mm²) power circuit
    MountingRail or plate, on 2 DIN rails or screw fixing
    Operating Temperature Range-40 to 60 °C, with derating up to 70 °C
    Dimensions6.22 in (158 mm) height, 4.72 in (120 mm) width, 5.35 in (136 mm) depth
    Fire Resistance850 °C IEC 60695-2-1
    Mechanical RobustnessVibrations: 2 Gn open, 4 Gn closed; Shocks: 6 Gn open, 15 Gn closed (11 ms)
    Country of OriginCzech Republic
    PVC FreeYes

    Accessories