TeSys K Reversing Contactor 3P 9A 440V AC with 24V Coil
Schneider Electric

Schneider Electric LC2K0910B7 TeSys K Reversing Contactor 3P 9A 440V AC with 24V Coil

  • MPN: LC2K0910B7
  • PPN: SCH-LC2K0910B7

CAD

$186.52

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides 24V 50/60Hz AC coils, 2NO built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Documentation & Downloads

Specifications

Key Specifications

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
[Uc] Control Circuit Voltage
24 V AC 50/60 Hz
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current
20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Mounting Support
rail || plate
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Irms Rated Making Capacity
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Associated Fuse Rating
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Pole Contact Composition
3 NO
Utilisation Category
AC-3 || AC-3e || AC-4 || AC-1
Maximum Operating Rate
3600 cyc/h
Mechanical Durability
5 Mcycles
Operating Time
10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
Overvoltage Category
III
[Ui] Rated Insulation Voltage
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
Device Short Name
LC2K
Interlocking Typemechanical
[Ue] Rated Operational Voltagepower circuit 690 V AC 50/60 Hz || signalling circuit <= 690 V AC 50/60 Hz
Auxiliary Contact Composition1 NO
StandardsEN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Control Circuit TypeAC 50/60 Hz
Contactor Applicationmotor control || resistive load
Product Or Component Typereversing contactor
Product NameTeSys K
[Uimp] Rated Impulse Withstand Voltage8 kV
RangeTeSys
Device Presentationpreassembled with reversing power busbar
[Ie] Rated Operational Current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Electrical Durability1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Poles Description3P
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Motor Power Kw2.2 kW 220...230 V AC 50/60 Hz || 4 kW 380...415 V AC 50/60 Hz || 4 kW 440/690 V AC 50/60 Hz
Device Applicationcontrol
[Icw] Rated Short-Time Withstand Current90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit

Complementary

Minimum Switching Current
5 mA for signalling circuit
Non Overlap Distance
0.5 mm
Inrush Power In Va
30-30 VA (at 20 °C)
Signalling Circuit Frequency
<= 400 Hz
Hold-In Power Consumption In Va
4.5-4.5 VA (at 20 °C)
Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at <50 °C) || drop-out: 0.2...0.75 Uc (at <50 °C)
Insulation Resistance> 10 MOhm for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Auxiliary Contacts Typeinstantaneous 1 NO
Heat Dissipation1.3-1.3 W

Environment

Mechanical Robustness
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height
58 mm
Flame Retardance
V1 UL 94 || requirement 2 NF F 16-101 || requirement 2 NF F 16-102
Protective Treatment
TC IEC 60068 || TC DIN 50016
Operating Altitude
2000 m without derating
Depth
57 mm
Ambient Air Temperature For Operation-25-50 °C
Net Weight0.39 kg
Ambient Air Temperature For Storage-50-80 °C
Ip Degree Of ProtectionIP20 VDE 0106
Width90 mm

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1503003EN
Toxic Heavy Metal Free
Yes
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive
Compliant
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Reach RegulationFree of Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity ProfileENVEOLI1503003EN

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$186.52/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!