Schneider Electric LC1D25G7TQ TeSys Deca Contactor 3P 25A 120V AC 50/60Hz Coil, Bulk Pack of 5


Schneider Electric LC1D25G7TQ TeSys Deca Contactor 3P 25A 120V AC 50/60Hz Coil, Bulk Pack of 5
- MPN: LC1D25G7TQ
- PPN: SCH-LC1D25G7TQ
Spec sheet
Loading compare button...
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
CAD$259.54/ EA
Description
Specifications
Complementary
- Non-Overlap Time
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Power Dissipation Per Pole
- 3.2 W AC-1 || 1.25 W AC-3 || 1.25 W AC-3e
- Auxiliary Contact Composition
- 1 NO + 1 NC
- Control Circuit Voltage Limits
- 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
- Contact Compatibility
- M2
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Insulation Resistance
- > 10 MOhm for signalling circuit
- Irms Rated Making Capacity
- 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
- Inrush Power In Va
- 70-70 VA 60 Hz cos phi 0.75 (at 20 °C) || 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
- Pole Contact Composition
- 3 NO
- Coil Technology
- without built-in suppressor module
- Minimum Switching Voltage
- 17 V for signalling circuit
- Signalling Circuit Frequency
- 25...400 Hz
- Electrical Durability
- 1.65 Mcycles 25 A AC-3 <= 440 V || 1.4 Mcycles 40 A AC-1 <= 440 V || 1.65 Mcycles 25 A AC-3e <= 440 V
- Auxiliary Contacts Type
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Hold-In Power Consumption In Va
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C) || 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
- Motor Power Hp
- 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors || 2 hp at 115 V AC 50/60 Hz for 1 phase motors || 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors || 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- [Ui] Rated Insulation Voltage
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 600 V CSA || signalling circuit 600 V UL || signalling circuit 690 V IEC 60947-1
- Heat Dissipation
- 2-3 W at 50/60 Hz
Environment
- Product Certifications
- BV || CCC || CSA || DNV || EAC || GL || LROS (Lloyds register of shipping) || UL || RINA || UKCA
- Standards
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Net Weight
- 0.37 kg
- Ip Degree Of Protection
- IP20 front face IEC 60529
- Operating Altitude
- 0...3000 m
- Width
- 45 mm
- Permissible Ambient Air Temperature Around The Device
- -40-60 °C || 60-70 °C with derating
Offer Sustainability
- Rohs Exemption Information
- Yes
- Environmental Disclosure
- ENVPEP110229EN
- Pvc Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
- Circularity Profile
- ENVEOLI110229EN
Specifications
- [Uc] Control Circuit Voltage
- 120 V AC 50/60 Hz
- Range Of Product
- TeSys Deca
- Product Or Component Type
- contactor
- Utilisation Category
- AC-3 || AC-1 || AC-3e
- Poles Description
- 3P