TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Features

  • Featuring an integrated adjustment dial, this thermal overload relay allows for precise current setting within the 4 to 6 Amp range. This allows industrial technicians to dial in the exact Full Load Amps (FLA) of their motor, providing a customized protection envelope that prevents motor burnout without causing premature tripping during standard operation.
  • Engineered for seamless integration, this relay is designed to mount directly beneath Schneider Electric TeSys D contactors (specifically models LC1D09 through LC1D38). This direct-link architecture eliminates the need for extra wiring and DIN rail space, creating a compact, vibration-resistant motor starter assembly that simplifies control panel layout and speeds up installation time.
  • Equipped with a blue "Reset" button and a red "Stop" button, this unit offers flexible control over fault recovery, allowing you to choose between manual intervention or automatic system restart. The built-in test function simulates a trip to verify the internal mechanism and auxiliary contact integrity, ensuring your safety circuits are fully operational before a real-world fault occurs.
  • Built to operate consistently across a wide temperature spectrum, the LRD106 features internal compensation that prevents "nuisance tripping" caused by high ambient heat within the electrical cabinet. This thermal stability ensures that the relay only reacts to actual motor overcurrent conditions, maintaining high levels of uptime for your conveyor systems and ventilation fans even in demanding environments.

Specifications

Rated Operational Voltage
690 V AC 0...400 Hz power circuit IEC 60947-4-1
Thermal Overload Class
Class 10A IEC 60947-4-1
Permissible Current
3 A 120 V AC-15 signalling circuit, 0.22 A 125 V DC-13 signalling circuit
Connection Pitch
14.5 mm
Height
66 mm
Net Weight
0.124 kg
Mounting Support
Plate or DIN rail with specific accessories, under contactor
Material
Not specified
Dielectric Strength
1.89 kV 50 Hz IEC 60947-1
IP Degree of Protection
IP20 IEC 60529
Ambient Air Temperature for Storage
-60 to 70 °C
Product Certification
IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, Lloyds Register, ATEX INERIS, UKCA
Thermal Protection Adjustment Range4-6 A
Tripping Current Threshold1.14 ± 0.06 x Ir IEC 60947-4-1
Phase Failure SensitivityTripping at 130% of Ir on two phases with the last one at 0
Width45 mm
Depth70 mm
Connection TypeScrew clamp terminals
Tightening TorqueControl circuit 1.7 N.m screw clamp terminals, power circuit 2.3 N.m lugs-ring terminals M4
Flame RetardanceV1 UL 94
Rated Insulation Voltage600 V CSA/UL, 690 V IEC 60947-4-1 power circuit
Ambient Air Temperature for Operation-20 to 60 °C without derating IEC 60947-4-1
StandardsIEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, CSA 22.2 No 60947-4-1
Country of OriginFrance (FR)

Downloads

Similar Products

TeSys Deca Thermal Overload Relay 690V, 30-38A, 1NO+1NC, Class 10A

Schneider Electric LRD35 TeSys Deca Thermal Overload Relay 690V, 30-38A, 1NO+1NC, Class 10A

MPN

LRD35

In Stock

Company Stock:

00

CAD$181.82/EA
TeSys Deca Thermal Overload Relay 0.1-0.16A 690VAC 1NO+1NC Class 10A

Schneider Electric LRD01 TeSys Deca Thermal Overload Relay 0.1-0.16A 690VAC 1NO+1NC Class 10A

MPN

LRD01

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay 690VAC 1.6-2.5A 1NO+1NC Class 10A

Schneider Electric LRD07 TeSys Deca Thermal Overload Relay 690VAC 1.6-2.5A 1NO+1NC Class 10A

MPN

LRD07

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay 690VAC 1-1.6A Class 10A 1NO+1NC

Schneider Electric LRD06 TeSys Deca Thermal Overload Relay 690VAC 1-1.6A Class 10A 1NO+1NC

MPN

LRD06

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay 16-24A 1NO+1NC Class 10A

Schneider Electric LRD22 TeSys Deca Thermal Overload Relay 16-24A 1NO+1NC Class 10A

MPN

LRD22

In Stock

Company Stock:

00

CAD$144.88/EA
TeSys Deca Thermal Overload Relay, 690VAC, 7-10A, 1NO+1NC, Class 10A

Schneider Electric LRD14 TeSys Deca Thermal Overload Relay, 690VAC, 7-10A, 1NO+1NC, Class 10A

MPN

LRD14

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay, 690VAC, 4-6A, 3P, Class 10A

Schneider Electric LRD10 TeSys Deca Thermal Overload Relay, 690VAC, 4-6A, 3P, Class 10A

MPN

LRD10

In Stock

Company Stock:

00

CAD$124.05/EA
Thermal Overload Relay 9-13A Class 10A 1NO+1NC, 66mm Height

Schneider Electric LRD16 Thermal Overload Relay 9-13A Class 10A 1NO+1NC, 66mm Height

MPN

LRD16

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A

Schneider Electric LRD03 TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A

MPN

LRD03

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay 690VAC 3P 2.5-4A Class 10A

Schneider Electric LRD08 TeSys Deca Thermal Overload Relay 690VAC 3P 2.5-4A Class 10A

MPN

LRD08

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay, 0.63-1A, 690VAC, Class 10A

Schneider Electric LRD05 TeSys Deca Thermal Overload Relay, 0.63-1A, 690VAC, Class 10A

MPN

LRD05

In Stock

Company Stock:

00

CAD$124.05/EA
TeSys Deca Thermal Overload Relay 0.4-0.63A 690V Class 10A

Schneider Electric LRD04 TeSys Deca Thermal Overload Relay 0.4-0.63A 690V Class 10A

MPN

LRD04

In Stock

Company Stock:

00

CAD$124.05/EA

Accessories

Loading carousel layout...

CAD$137.31/ EA

Loading add to cart quantity...

banner

Need assistance finding the right item?

We can help! Connect with our Sales Team Today!