TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A
TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A
TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A
Schneider Electric

Schneider Electric LRD03 TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A

  • MPN: LRD03
  • PPN: SCH-LRD03

CAD

$124.05

/ EA

Available to Order

Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

LRD03 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 0.06-0.09kW@400V thanks to a thermal range 0.25-0.40A, a tripping class 10A and phase unbalance protection. LRD03 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 0.25-0.40A, a tripping class 10A and phase unbalance detection, it protects motors 0.06-0.09kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D09-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).

Features

  • Belonging to the premium TeSys Deca (formerly TeSys D) family, this module features a front-mounted adjustable dial with a precise thermal protection setting range of 0.25 to 0.4 Amps. It adheres strictly to Class 10A tripping characteristics conforming to IEC 60947-4-1, meaning it guarantees a reliable trip within 10 seconds during a locked-rotor or high-current stall condition.
  • The faceplate is equipped with a transparent, sealable protective cover shielding a manual/automatic reset selector, a test button to simulate standard tripping, an independent stop button, and a visual trip indicator flag. It also houses an integrated 1 NO (Normally Open) + 1 NC (Normally Closed) auxiliary contact set, allowing the NC contact to drop out the main contactor coil while the NO contact simultaneously passes a fault signal to a PLC or pilot light.

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, China, France, Thailand, United States
Depth70 mm

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SC
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
4 A gG for signalling circuit, 4 A BS for signalling circuit
Mounting Support
plate, with specific accessories, rail, with specific accessories, under contactor
Permissible Current
3 A 120 V AC-15 signalling circuit, 0.22 A 125 V DC-13 signalling circuit
Range
TeSys, TeSys Deca
Tightening Torque
control circuit 1.7 N.m screw clamp terminals, power circuit 1.7 N.m screw clamp terminals
[Ui] Rated Insulation Voltage
power circuit 600 V CSA, power circuit 600 V ULpower circuit 690 V IEC 60947-4-1
Carbon Footprint Of The Distribution Phase [A4]
0.024163479198025903, 0 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]
0 kg CO2 eq., 0.01635889814277638
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]
12 kg CO2 eq., 11.633004615445152
Local Publishable Date
2026-06-27
Stocking Flag
Y
Device Type
Relay, Control & Measurement - Protection relay
Traceability
No
Weee Product Category
5
Eoli Availability Display
Yes
Reach Full Compliance Status
Free of Substances of Very High Concern above the threshold
Reach Compliance Directive
Free of Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant
Rohs Eur Full Compliance Status
Compliant
China Rohs Label
1
Without Single Use Plastic
Yes
Tier Id
1
Function Option Id
STANDARD
Product Kit Identifier
N
Control Type
Red push-button stopBlue push-button reset
Dielectric Strength
1.89 kV 50 Hz IEC 60947-1
Network Frequency
0...400 Hz
Product Availability
Stock - Normally stocked in distribution facility
Relay Application
motor protection
Software Version
v6.1
Thermal Overload Class
class 10A IEC 60947-4-1
Total Lifecycle Carbon Footprint
13 kg CO2 eq.
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep Code
ENVPEP0802006EN
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed3-EN-2023 06 06
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime In Y
20
Energy Model - Manufacturing [A1-a3]
Europe, EU-27
Energy Model - Use [B6]
Electricity Mix; Low voltage; 2018; Europe, EU-27
Recyclability Potential In %
50
Width Nominal
45 mm
[Ue] Rated Operational Voltage
690 V AC 0...400 Hz power circuit IEC 60947-4-1
Nbr. Of Units In Pkg.
1
Take-back
No
Customs Code
8536490075
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
Market SegmentationCommercial, Industrial
Mechanical Robustnessvibrations6 Gn IEC 60068-2-6, shocks15 Gn for 11 ms IEC 60068-2-7
Network TypeAC, DC
Product NameTeSys LRD, TeSys Deca
Temperature Compensation-20-60 °C, -20-60 °C
Certificate AgencyIEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS (Lloyds register of shipping), ATEX INERIS, UKCA
Connections - Terminalspower circuit screw clamp terminals 1 1-4 mm² flexible with cable endpower circuit screw clamp terminals 1 1-6 mm² solid without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end, power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end
Carbon Footprint Of The End-of-life Phase [C1 To C4]0.21678519324421383, 0.2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]1 kg CO2 eq., 1.0267614686619415
Local Data StatusPublishable
Return IndicatorY
Stock Policy1
ServiceabilityNo
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI0802006
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date0627
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Compatibility CodeLRD
Device Short NameLRD
Flame RetardanceV1 conforming to UL 94
Phase Failure Sensitivitytripping current 130 % of Ir on two phase, the last one at 0
Product Or Component Typedifferential thermal overload relay
ReturnabilityYes
Sustainable PackagingNo
Thermal Protection Adjustment Range0.25-0.4 A
Tripping Threshold1.14 +/- 0.06 Ir IEC 60947-4-1
R Thermal Protection Adj Range0.25-0.4 A
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionOther switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh28.3824
Energy Model - Installation [A5]Electricity Mix; Low voltage; 2018; Europe, EU-27
Energy Model - End Of Life [C1-c4]Electricity Mix; Low voltage; 2018; Europe, EU-27
Height Nominal66 mm
[Ith] Conventional Free Air Thermal Current5 A signalling circuit
[Uimp] Rated Impulse Withstand Voltage6 kV
Package Weight(Lbs)137.000 g
Warranty (In Months)18

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Ambient Air Temperature For Storage
-60-70 °C, -60-70 °C
Take Back
No
Recycled Metal Content At Cr Level
0 %
Mercury Free
Yes
Circularity Profile
ENVEOLI0802006
Environmental Disclosure
ENVPEP0802006EN
Ip Degree Of Protection
IP20 conforming to IEC 60529
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed3-EN-2023 06 06
Ambient Air Temperature For Operation-20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1-20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1
Product CompatibilityLC1D25, LC1D18, LC1D38, LC1D12, LC1D32, LC1D09
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint12.917073654692109
Climatic WithstandIACS E10
Eu Rohs DirectiveCompliant
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP0802006EN
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Type
differential thermal overload relay

ETIM

ETIM 8
EC000106
ETIM 9EC000106

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$124.05/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!