Schneider Electric

Schneider Electric LRD03 TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A

  • MPN: LRD03
  • PPN: SCH-LRD03

CAD

$124.05

/ EA

Available to Order

Available to Ship Same/Next Business Day if In Stock and Ordered before 12:00 PM EST

Available To Ship Immediately:0

Loading dialog...

Looking to buy a large quantity?

To View Branch Inventory And Your Custom Pricing

Spec sheet

Description

LRD03 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 0.06-0.09kW@400V thanks to a thermal range 0.25-0.40A, a tripping class 10A and phase unbalance protection. LRD03 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 0.25-0.40A, a tripping class 10A and phase unbalance detection, it protects motors 0.06-0.09kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D09-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).

Features

  • Belonging to the premium TeSys Deca (formerly TeSys D) family, this module features a front-mounted adjustable dial with a precise thermal protection setting range of 0.25 to 0.4 Amps. It adheres strictly to Class 10A tripping characteristics conforming to IEC 60947-4-1, meaning it guarantees a reliable trip within 10 seconds during a locked-rotor or high-current stall condition.
  • The faceplate is equipped with a transparent, sealable protective cover shielding a manual/automatic reset selector, a test button to simulate standard tripping, an independent stop button, and a visual trip indicator flag. It also houses an integrated 1 NO (Normally Open) + 1 NC (Normally Closed) auxiliary contact set, allowing the NC contact to drop out the main contactor coil while the NO contact simultaneously passes a fault signal to a PLC or pilot light.

Documentation & Downloads

Specifications

Key Specifications

Country of OriginBrazil, China, France, Thailand, United States
Depth70 mm

Important Information Attributes

Persona Type IdsEU, LC, OM, OM8, PB, SC
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Associated Fuse Rating4 A gG for signalling circuit, 4 A BS for signalling circuit
Mounting Supportplate, with specific accessories, rail, with specific accessories, under contactor
Permissible Current3 A 120 V AC-15 signalling circuit, 0.22 A 125 V DC-13 signalling circuit
RangeTeSys, TeSys Deca
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals, power circuit 1.7 N.m screw clamp terminals
[Ui] Rated Insulation Voltagepower circuit 600 V CSA, power circuit 600 V ULpower circuit 690 V IEC 60947-4-1
Carbon Footprint Of The Distribution Phase [A4]0.024163479198025903, 0 kg CO2 eq.
Carbon Footprint Of The Installation Phase [A5]0 kg CO2 eq., 0.01635889814277638
Carbon Footprint Of The Use Phase [B2 B3 B4 B6]12 kg CO2 eq., 11.633004615445152
Local Publishable Date2026-06-27
Stocking FlagY
Device TypeRelay, Control & Measurement - Protection relay
TraceabilityNo
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Control TypeRed push-button stopBlue push-button reset
Dielectric Strength1.89 kV 50 Hz IEC 60947-1
Network Frequency0...400 Hz
Product AvailabilityStock - Normally stocked in distribution facility
Relay Applicationmotor protection
Software Versionv6.1
Thermal Overload Classclass 10A IEC 60947-4-1
Total Lifecycle Carbon Footprint13 kg CO2 eq.
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep CodeENVPEP0802006EN
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed3-EN-2023 06 06
Data Sourceextrapolated product
Functional-unit Quantity1
Reference Lifetime In Y20
Energy Model - Manufacturing [A1-a3]Europe, EU-27
Energy Model - Use [B6]Electricity Mix; Low voltage; 2018; Europe, EU-27
Recyclability Potential In %50
Width Nominal45 mm
[Ue] Rated Operational Voltage690 V AC 0...400 Hz power circuit IEC 60947-4-1
Nbr. Of Units In Pkg.1
Take-backNo
Customs Code8536490075
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
Market SegmentationCommercial, Industrial
Mechanical Robustnessvibrations6 Gn IEC 60068-2-6, shocks15 Gn for 11 ms IEC 60068-2-7
Network TypeAC, DC
Product NameTeSys LRD, TeSys Deca
Temperature Compensation-20-60 °C, -20-60 °C
Certificate AgencyIEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS (Lloyds register of shipping), ATEX INERIS, UKCA
Connections - Terminalspower circuit screw clamp terminals 1 1-4 mm² flexible with cable endpower circuit screw clamp terminals 1 1-6 mm² solid without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end, power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end
Carbon Footprint Of The End-of-life Phase [C1 To C4]0.21678519324421383, 0.2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]1 kg CO2 eq., 1.0267614686619415
Local Data StatusPublishable
Return IndicatorY
Stock Policy1
ServiceabilityNo
Weee ScopeIn
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI0802006
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
Rohs Eur In ScopeYes
Rohs Eur Conformity Date0627
China Rohs In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Tier1
Function OptionStandard
Compatibility CodeLRD
Device Short NameLRD
Flame RetardanceV1 conforming to UL 94
Phase Failure Sensitivitytripping current 130 % of Ir on two phase, the last one at 0
Product Or Component Typedifferential thermal overload relay
ReturnabilityYes
Sustainable PackagingNo
Thermal Protection Adjustment Range0.25-0.4 A
Tripping Threshold1.14 +/- 0.06 Ir IEC 60947-4-1
R Thermal Protection Adj Range0.25-0.4 A
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional-unit DescriptionOther switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
Functional-unit Unitunit
Energy Consumption On Product Lifetime In Kwh28.3824
Energy Model - Installation [A5]Electricity Mix; Low voltage; 2018; Europe, EU-27
Energy Model - End Of Life [C1-c4]Electricity Mix; Low voltage; 2018; Europe, EU-27
Height Nominal66 mm
[Ith] Conventional Free Air Thermal Current5 A signalling circuit
[Uimp] Rated Impulse Withstand Voltage6 kV
Package Weight(Lbs)137.000 g
Warranty (In Months)18

Environment Attributes Main

China Rohs RegulationProduct out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Ambient Air Temperature For Storage-60-70 °C, -60-70 °C
Take BackNo
Recycled Metal Content At Cr Level0 %
Mercury FreeYes
Circularity ProfileENVEOLI0802006
Environmental DisclosureENVPEP0802006EN
Ip Degree Of ProtectionIP20 conforming to IEC 60529
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed3-EN-2023 06 06
Ambient Air Temperature For Operation-20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1-20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1, -20-60 °C without derating IEC 60947-4-1
Product CompatibilityLC1D25, LC1D18, LC1D38, LC1D12, LC1D32, LC1D09
Reach Free ShvcYes
Toxic Heavy Metal FreeYes
Carbon Footprint12.917073654692109
Climatic WithstandIACS E10
Eu Rohs DirectiveCompliant
Packaging Made With Recycled CardboardYes
Reach Free Of SvhcYes
Pep CodeENVPEP0802006EN
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review

General Attributes

Product Or Component Typedifferential thermal overload relay

ETIM

ETIM 8EC000106
ETIM 9EC000106

Contractual Warranty Attributes

Warranty Period18 months
Warranty18 months
TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A
TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A
TeSys Deca Thermal Overload Relay 690VAC 0.25-0.4A Class 10A

Similar Products

Loading carousel layout...

CAD$124.05/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!