Schneider Electric

Schneider Electric LC1D32V7 TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC

TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
  • MPN: LC1D32V7
  • PPN: SCH-LC1D32V7
  • UNSPSC: 39121529

Spec sheet

In Stock

Company Stock:

00

Lead times may vary. For an accurate estimate please contact us.

Loading dialog...

Looking to buy a large quantity?

To view product inventory

CAD$318.02/ EA

Specifications

Conformance Attributes

Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, CSA C22.2 No 60947-4-1

Complementary Attributes

Control Circuit Voltage Limits
0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating
2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
IE Rated Operational Current
32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
UI Rated Insulation Voltage
power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 690 V IEC 60947-4-1
Maximum Motor Phase Current
32 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
550 A at 440 V for power circuit conforming to IEC 60947
UIMP Rated Impulse Withstand Voltage
6 kV IEC 60947
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
ICW Rated Short Time Withstand Current60 A 40 °C - 10 min for power circuit, 138 A 40 °C - 1 min for power circuit, 260 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
UE Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Control Circuit TypeAC 50/60 Hz standard
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit
UC Control Circuit Voltage400 V AC 50/60 Hz

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
1.65 Mcycles 32 A AC-3 <= 440 V, 1.4 Mcycles 50 A AC-1 <= 440 V, 1.65 Mcycles 32 A AC-3e <= 440 V
Inrush Power In VA
70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms)
Non Overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Power Dissipation Per Pole
2 W AC-3, 5 W AC-1, 2 W AC-3e
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
ICW Rated Short Time Withstand Current
60 A 40 °C - 10 min for power circuit, 138 A 40 °C - 1 min for power circuit, 260 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
ITH Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
Carbon Footprint Of The End Of Life Phase C1 To C4
0.9107704459160854, 0.9 kg CO2 eq.
Carbon Footprint Of The Use Phase B2 B3 B4 B6
144 kg CO2 eq., 143.61734093142167
Auxiliaries
LADN22, LADN11, LADN20, LAD8N11, LADT2, LADN40, LADN31
Local Publishable Date
2025-05-31
Serviceability
No
Field Service Division
PPIBS
Legacy WEEE Scope
In
EOLI Availability Display
Yes
Reach Full Compliance Status
Free of Substances of Very High Concern above the threshold
Reach Compliance Directive
Free of Substances of Very High Concern above the threshold
ROHS EUR Status
Compliant
ROHS EUR Full Compliance Status Id
COMPLIANT
Green Premium Status For Reporting
Green Premium product
Without Single Use Plastic
Yes
Return Indicator
N
Function Option Id
STANDARD
Average Impedance
2 mOhm - Ith 50 A 50 Hz for power circuit
Compatibility Code
LC1D
Device Short Name
LC1D
Flame Retardance
V1 conforming to UL 94
Package Weight Lbs
416.000 g
Product Or Component Type
contactor
Range Of Product
TeSys Deca
Signalling Circuit Frequency
25...400 Hz
Total Lifecycle Carbon Footprint
147 kg CO2 eq.
Relationship Type
Compatible relationship
Pep Verification Date
2025-08-05
PSR Version
PSR-0005-ed3.1-EN-2023 12 08
Functional Unit Description
Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Product Kit Identifier
N
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Hold In Power Consumption In VA7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Insulation Resistance> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power KW7.5 kW at 220...230 V AC 50/60 Hz (AC-3), 15 kW at 380...400 V AC 50/60 Hz (AC-3), 15 kW at 415...440 V AC 50/60 Hz (AC-3), 18.5 kW at 500 V AC 50/60 Hz (AC-3), 18.5 kW at 660...690 V AC 50/60 Hz (AC-3), 7.5 kW at 400 V AC 50/60 Hz (AC-4), 7.5 kW at 220...230 V AC 50/60 Hz (AC-3e), 15 kW at 380...400 V AC 50/60 Hz (AC-3e), 15 kW at 415...440 V AC 50/60 Hz (AC-3e), 18.5 kW at 500 V AC 50/60 Hz (AC-3e), 18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Operating Time4...19 ms opening, 12...22 ms closing
RangeTeSys, TeSys Deca
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm, power circuit 2.5 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2
IE Rated Operational Current32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Carbon Footprint Of The Distribution Phase A40.17403709638325782, 0.2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A32 kg CO2 eq., 2.305182478065738
Connections Terminalscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end
Local Data StatusPublishable
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI110229EN
Reach Full Compliance Status IdNOT_CONTAINING_SVHC
ROHS EUR In ScopeYes
ROHS EUR Full Compliance StatusCompliant
China ROHS In ScopeNo
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
WD Status1 - GSC certified
Function OptionStandard
Coil Technologywithout built-in suppressor module
Contact CompatibilityM2
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation2-3 W at 50/60 Hz
Product AvailabilityNon-Stock - Not normally stocked in distribution facility
Protective TreatmentTHIEC 60068-2-30
ReturnabilityNo
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep CodeENVPEP1102029EN
PCR VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review
Functional Unit Unitunit
Product ManagerNANNAN YAN

Environment Attributes Main

Climatic Withstand
IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device
-40-60 °C, 60-70 °C with derating
Take Back
No
Recycled Metal Content At Cr Level
0 %
Carbon Footprint
147.00733095178674
Environmental Disclosure
ENVPEP1102029EN
Operating Altitude
0...9842.52 ft (0...3000 m)
Packaging Without Single Use Plastic
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Pep Verification Date
2025-08-05
PSR Version
PSR-0005-ed3.1-EN-2023 12 08
EU ROHS DirectiveCompliant?, Compliant
ROHS Exemption InformationYes
Reach Free SHVCYes
China ROHS RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Circularity ProfileENVEOLI110229EN
IP Degree Of ProtectionIP20 front face IEC 60529
Packaging Made With Recycled CardboardYes
Reach Free Of SVHCYes
Pep CodeENVPEP1102029EN
PCR VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Downloads

Similar Products

TeSys Deca Contactor 3P 32A 120V AC Coil Compact Design

Schneider Electric LC1D32G7 TeSys Deca Contactor 3P 32A 120V AC Coil Compact Design

MPN

LC1D32G7

In Stock

Company Stock:

00

CAD$318.02/EA
TeSys Deca Contactor 3P 32A 110V AC Coil, Screw Clamp Terminals

Schneider Electric LC1D32F7 TeSys Deca Contactor 3P 32A 110V AC Coil, Screw Clamp Terminals

MPN

LC1D32F7

In Stock

Company Stock:

00

CAD$318.02/EA
TeSys Deca Reversing Contactor, 3P, 9A, 24V AC, 90mm Width

Schneider Electric LC2D09B7 TeSys Deca Reversing Contactor, 3P, 9A, 24V AC, 90mm Width

MPN

LC2D09B7

In Stock

Company Stock:

00

CAD$455.09/EA
TeSys Deca Contactor 3P 32A 24V DC with Screw Clamp Terminals

Schneider Electric LC1D32BD TeSys Deca Contactor 3P 32A 24V DC with Screw Clamp Terminals

MPN

LC1D32BD

In Stock

Company Stock:

00

CAD$363.11/EA
TeSys Deca Contactor Coil 240V AC 50/60Hz for 80A & 95A Contactors

Schneider Electric LX1D6U7 TeSys Deca Contactor Coil 240V AC 50/60Hz for 80A & 95A Contactors

MPN

LX1D6U7

In Stock

Company Stock:

00

CAD$179.72/EA
TeSys Deca Contactor 4P 32A 120V AC Coil, Screw Clamp Terminal

Schneider Electric LC1D188G7 TeSys Deca Contactor 4P 32A 120V AC Coil, Screw Clamp Terminal

MPN

LC1D188G7

In Stock

Company Stock:

00

CAD$303.40/EA
TeSys Deca Contactor 4P 32A 440V AC 120V Coil

Schneider Electric LC1DT32G7 TeSys Deca Contactor 4P 32A 440V AC 120V Coil

MPN

LC1DT32G7

In Stock

Company Stock:

00

CAD$280.86/EA
TeSys Deca Contactor, 4P (2NO+2NC), 40A, 120V AC Coil, IP20

Schneider Electric LC1D258G7 TeSys Deca Contactor, 4P (2NO+2NC), 40A, 120V AC Coil, IP20

MPN

LC1D258G7

In Stock

Company Stock:

00

CAD$461.18/EA
TeSys Deca Contactor 3-Pole 9A 24V DC Coil, IP20 45mm Width

Schneider Electric LC1D09BD TeSys Deca Contactor 3-Pole 9A 24V DC Coil, IP20 45mm Width

MPN

LC1D09BD

In Stock

Company Stock:

00

CAD$196.17/EA
TeSys Deca Contactor 3-Pole 65A 120V AC with Screw Clamp Terminals

Schneider Electric LC1D65G7 TeSys Deca Contactor 3-Pole 65A 120V AC with Screw Clamp Terminals

MPN

LC1D65G7

In Stock

Company Stock:

00

CAD$478.25/EA
TeSys Deca 3P Contactors, 80A, 440V, 120V AC Coil, Compact 85mm

Schneider Electric LC1D80G7 TeSys Deca 3P Contactors, 80A, 440V, 120V AC Coil, Compact 85mm

MPN

LC1D80G7

In Stock

Company Stock:

00

CAD$554.40/EA
TeSys Deca Contactor, 3 Pole, 12A, 24V AC Coil, Compact Design

Schneider Electric LC1D12B7 TeSys Deca Contactor, 3 Pole, 12A, 24V AC Coil, Compact Design

MPN

LC1D12B7

In Stock

Company Stock:

00

CAD$196.17/EA

You might also be interested in

Loading carousel layout...

Others Also Viewed

Loading carousel layout...

CAD$318.02/ EA

Loading add to cart quantity...

banner

Need assistance finding the right item?

We can help! Connect with our Sales Team Today!