TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC
Schneider Electric

Schneider Electric LC1D32V7 TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC

  • MPN: LC1D32V7
  • PPN: SCH-LC1D32V7

CAD

$337.14

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Loading dialog...

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys Deca Non-Reversing Contactor 32A 20HP 3NO 400VAC

Documentation & Downloads

Specifications

Key Specifications

Country of Origin
Brazil, France, Indonesia, Philippines
Depth92 mm

Complementary Attributes

Control Circuit Voltage Limits
0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Maximum Horse Power Rating
10 hp at 230/240 V AC 50/60 Hz for 3 phase motors2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Maximum Motor Phase Current
32 A
Minimum Switching Current
5 mA for signalling circuit
Rated Breaking Capacity
550 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
Control Circuit TypeAC 50/60 Hz standard
Maximum Operating Rate3600 cyc/h at 60 °C
Minimum Switching Voltage17 V for signalling circuit

Important Information Attributes

Persona Type Ids
EU, LC, OM, OM8, PB, SI
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability
1.65 Mcycles 32 A AC-3 <= 440 V, 1.4 Mcycles 50 A AC-1 <= 440 V, 1.65 Mcycles 32 A AC-3e <= 440 V
Insulation Resistance
> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
Motor Power Kw
15 kW at 380...400 V AC 50/60 Hz (AC-3e), 15 kW at 415...440 V AC 50/60 Hz (AC-3e), 18.5 kW at 500 V AC 50/60 Hz (AC-3e), 18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)7.5 kW at 220...230 V AC 50/60 Hz (AC-3), 15 kW at 380...400 V AC 50/60 Hz (AC-3), 15 kW at 415...440 V AC 50/60 Hz (AC-3), 18.5 kW at 500 V AC 50/60 Hz (AC-3), 18.5 kW at 660...690 V AC 50/60 Hz (AC-3), 7.5 kW at 400 V AC 50/60 Hz (AC-4), 7.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
Operating Time
4...19 ms opening, 12...22 ms closing
Range
TeSys, TeSys Deca
Tightening Torque
power circuit 2.5 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals pozidriv No 2control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
Certificate Agency
UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
[Ie] Rated Operational Current
32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control Circuit Voltage
400 V, 400 V AC 50/60 Hz
[Ui] Rated Insulation Voltage
signalling circuit 600 V CSA, signalling circuit 600 V ULpower circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, power circuit 690 V IEC 60947-4-1
Hold-in Power Consumption In Va
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Carbon Footprint Of The Distribution Phase [A4]
0.17403709638325782, 0.2 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase [A1 To A3]
2 kg CO2 eq., 2.305182478065738
Local Data Status
Publishable
Return Indicator
N
Stock Policy
2
Serviceability
No
Field Service Division
PPIBS
Weee Scope
In
Scope Perimeter
At least in Europe
End Of Life Doc Ref
ENVEOLI110229EN
Reach Full Compliance Status Id
NOT_CONTAINING_SVHC
Rohs Eur In Scope
Yes
Rohs Eur Conformity Date
0627
China Rohs In Scope
No
With Recycled Cardboard
Yes
Product Contributes To Saved And Avoided Emissions
No
Tier
1
Function Option
Standard
Average Impedance
2 mOhm - Ith 50 A 50 Hz for power circuit
Compatibility Code
LC1D
Device Short Name
LC1D
Flame Retardance
V1 conforming to UL 94
Mechanical Durability
15 Mcycles
Overvoltage Category
III
Product Availability
Non-Stock - Not normally stocked in distribution facility
Protective Treatment
THIEC 60068-2-30
Returnability
No
Software Version
v6.1
Total Lifecycle Carbon Footprint
147 kg CO2 eq.
Control Circuit Voltage
400 V
Pep Code
ENVPEP1102029EN
Pep Verification Date
2025-08-05
Psr Version
PSR-0005-ed3.1-EN-2023 12 08
Data Source
extrapolated product
Functional-unit Quantity
1
Reference Lifetime, In Y
20
Energy Model - Manufacturing [A1-a3]
France, FR
Energy Model - Use [B6]
Electricity Mix; Low voltage; 2018; Europe, EU-27
Recyclability Potential, In %
66
Width Nominal
45 mm
Nbr. Of Units In Pkg.
1
Take-back
No
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market SegmentationCommercial, Industrial
Contactor Applicationmotor control, resistive load
Inrush Power In Va70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms)
Mounting Supportplate, rail
Power Dissipation Per Pole2 W AC-3, 5 W AC-1, 2 W AC-3e
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
[Icw] Rated Short-time Withstand Current60 A 40 °C - 10 min for power circuit, 138 A 40 °C - 1 min for power circuit, 260 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Connections - Terminalscontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end, screw clamp terminals, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
Non-overlap Time1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Carbon Footprint Of The End-of-life Phase [C1 To C4]0.9107704459160854, 0.9 kg CO2 eq.
Carbon Footprint Of The Use Phase [B2, B3, B4, B6]144 kg CO2 eq., 143.61734093142167
Local Publishable Date2026-04-12
Stocking FlagY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Weee Product Category5
Eoli Availability DisplayYes
Reach Full Compliance StatusFree of Substances of Very High Concern above the threshold
Reach Compliance DirectiveFree of Substances of Very High Concern above the threshold
Rohs Eur StatusCompliant
Rohs Eur Full Compliance StatusCompliant
China Rohs Label1
Without Single Use PlasticYes
Tier Id1
Function Option IdSTANDARD
Product Kit IdentifierN
Coil Technologywithout built-in suppressor module
Contact CompatibilityM2
Fire Resistance850 °C IEC 60695-2-1
Heat Dissipation2-3 W at 50/60 Hz
Number Of Poles3P
Pole Contact Composition3 NO
Product Or Component Typecontactor
Range Of ProductTeSys Deca
Signalling Circuit Frequency25...400 Hz
Sustainable PackagingYes
Weee LabelThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inf Motor Phase Current32 A
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent external review
Functional-unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Functional-unit Unitunit
Energy Consumption On Product Lifetime, In Kwh350.4
Energy Model - Installation [A5]Electricity Mix; Low voltage; 2018; Europe, EU-27
Energy Model - End Of Life [C1-c4]Electricity Mix; Low voltage; 2018; Europe, EU-27
Height Nominal85 mm
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Package Weight(Lbs)416.000 g
Warranty (In Months)18

Environment Attributes Main

China Rohs Regulation
Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
Permissible Ambient Air Temperature Around The Device
-40-60 °C-40-60 °C, 60-70 °C with derating
Reach Free Shvc
Yes
Carbon Footprint
147.00733095178674
Environmental Disclosure
ENVPEP1102029EN
Ip Degree Of Protection
IP20 front face IEC 60529
Packaging Made With Recycled Cardboard
Yes
Reach Free Of Svhc
Yes
Pep Code
ENVPEP1102029EN
Pcr Version
PCR-4-ed4-EN-2021 09 06
Type Of Verification For The Pep
Independent external review
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Take BackNo
Recycled Metal Content At Cr Level0 %
Circularity ProfileENVEOLI110229EN
Eu Rohs DirectiveCompliant
Operating Altitude0...9842.52 ft (0...3000 m)
Packaging Without Single Use PlasticYes
Reach RegulationFree of Substances of Very High Concern above the threshold
Pep Verification Date2025-08-05
Psr VersionPSR-0005-ed3.1-EN-2023 12 08

General Attributes

Product Or Component Type
contactor
Range Of ProductTeSys Deca

ETIM

ETIM 8
EC000066
ETIM 9EC000066

Contractual Warranty Attributes

Warranty Period
18 months
Warranty18 months

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$337.14/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])