    Description

    TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 150A/1000V AC-3 (75kW@400V). It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirrror contact), power connection by screw connectors 2 inputs, control connection by screw clamp terminals. For operating rates until 1200 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

    Documentation & Downloads

    Specifications

    Key Specifications

    [Uc] Control Circuit Voltage
    24 V DC
    Range Of Product
    TeSys Deca
    Product Or Component Type
    contactor
    Utilisation Category
    AC-3 || AC-4 || AC-1 || AC-3e
    Poles Description
    3P
    [Ue] Rated Operational Voltagepower circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
    Contactor Applicationresistive load || motor control
    RangeTeSys
    [Ie] Rated Operational Current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    Device Short NameLC1D

    Complementary

    Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    Power Dissipation Per Pole
    24 W AC-1 || 13.5 W AC-3 || 13.5 W AC-3e
    Auxiliary Contact Composition
    1 NO + 1 NC
    Control Circuit Voltage Limits
    0.75...1.2 Uc -40-55 °C operational DC || 0.15...0.4 Uc -40-70 °C drop-out DC || 1...1.2 Uc 55-70 °C operational DC
    Contact Compatibility
    M10
    Safety Reliability Level
    B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
    Hold-In Power Consumption In W
    2.4-5.1 W 20 °C
    Rated Breaking Capacity
    1400 A at 440 V for power circuit conforming to IEC 60947
    Associated Fuse Rating
    10 A gG for signalling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
    Pole Contact Composition
    3 NO
    Coil Technology
    with integral suppression device
    Operating Time
    20...35 ms closing || 40...75 ms opening
    Maximum Operating Rate
    1200 cyc/h 60 °C
    Tightening Torque
    control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
    Mechanical Durability
    8 Mcycles
    Auxiliary Contacts Type
    mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    Overvoltage Category
    III
    Motor Power Kw
    40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22 kW at 400 V AC 50/60 Hz (AC-4) || 40 kW at 220...230 V AC 50/60 Hz (AC-3e) || 75 kW at 380...400 V AC 50/60 Hz (AC-3e) || 80 kW at 415...440 V AC 50/60 Hz (AC-3e) || 90 kW at 500 V AC 50/60 Hz (AC-3e) || 100 kW at 660...690 V AC 50/60 Hz (AC-3e) || 75 kW at 1000 V AC 50/60 Hz (AC-3e)
    [Icw] Rated Short-Time Withstand Current
    250 A 40 °C - 10 min for power circuit || 580 A 40 °C - 1 min for power circuit || 1200 A 40 °C - 10 s for power circuit || 1400 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
    Minimum Switching Current5 mA for signalling circuit
    Average Impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
    [Ith] Conventional Free Air Thermal Current200 A (at 60 °C) for power circuit
    Mounting Supportrail || plate
    Control Circuit TypeDC standard
    Pollution Degree3
    Insulation Resistance> 10 MOhm for signalling circuit
    Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
    [Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
    Connections - Terminalscontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable end || power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end || power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end || power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end || power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end || power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end || power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end
    Time Constant25 ms
    Minimum Switching Voltage17 V for signalling circuit
    Signalling Circuit Frequency25...400 Hz
    Electrical Durability0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
    Inrush Power In W270-365 W 20 °C)
    Compatibility CodeLC1D
    Motor Power Hp40 hp at 200/208 V AC 50/60 Hz for 3 phases motors || 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors || 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors || 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
    [Ui] Rated Insulation Voltagepower circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
    Protective Coverwith

    Environment

    Product Certifications
    UL || BV || GL || GOST || CSA || CCC || LROS (Lloyds register of shipping) || RINA || DNV || UKCA || CE
    Standards
    CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
    Net Weight
    2.5 kg
    Protective Treatment
    THIEC 60068-2-30
    Mechanical Robustness
    vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
    Fire Resistance
    850 °C IEC 60695-2-1
    Depth
    136 mm
    Height158 mm
    Climatic WithstandIACS E10 exposure to damp heat
    Flame RetardanceV1 UL 94
    Ip Degree Of ProtectionIP20 front face IEC 60529
    Operating Altitude0...3000 m
    Width120 mm
    Permissible Ambient Air Temperature Around The Device-40-60 °C || 60-70 °C with derating

    Contractual warranty

    Warranty
    18 months

    Offer Sustainability

    Rohs Exemption Information
    Yes
    Environmental Disclosure
    ENVPEP060301EN
    Pvc Free
    Yes
    Weee
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Circularity Profile
    ENVEOLI100405EN
    Mercury FreeYes
    Sustainable Offer StatusGreen Premium product
    Reach RegulationReference contains Substances of Very High Concern above the threshold
    China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information
    Eu Rohs DirectiveCompliant with Exemptions

    Accessories

    Loading carousel layout...

    Accessories

    Loading carousel layout...

    Similar Products

    Loading carousel layout...

    CAD$1317.52/ EA

    Loading add to cart quantity...

    banner

    Need assistance?

    We can help! Connect with our Sales Team Today!