Schneider Electric LC1D50AF7TQ TeSys Deca Contactor, 3 Pole, 50A, 110V AC Coil, Compact Design
- MPN: LC1D50AF7TQ
- PPN: SCH-LC1D50AF7TQ
CAD
$413.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
Description
Documentation & Downloads
Specifications
Key Specifications
| [Uc] Control Circuit Voltage | 120 V AC 60 Hz |
|---|---|
| Range Of Product | TeSys Deca |
| Product Or Component Type | contactor |
| Utilisation Category | AC-1 || AC-2 || AC-3e || AC-4 |
| Poles Description | 3P |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz |
|---|---|
| Contactor Application | motor control || resistive load |
| Range | TeSys || TeSys Deca |
| [Ie] Rated Operational Current | 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Device Short Name | LC1D |
Complementary
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts |
|---|---|
| Power Dissipation Per Pole | 3.7 W AC-3e || 3.7 W AC-3 || 9.6 W AC-1 |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit |
| Mounting Support | rail || plate |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Rated Breaking Capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
| Associated Fuse Rating | 100 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Connections - Terminals | control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: rigid || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: rigid || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid |
| Operating Time | 4...19 ms opening || 12...26 ms closing |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Mechanical Durability | 6000000 cycles |
| Compatibility Code | LC1D |
| Overvoltage Category | III |
| Motor Power Kw | 30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 Hz (AC-3) || 11 kW at 400 V AC 50 Hz (AC-4) || 22 kW at 380...400 V AC 50 Hz (AC-3e) || 25 kW at 415 V AC 50 Hz (AC-3e) || 30 kW at 440 V AC 50 Hz (AC-3e) || 30 kW at 500 V AC 50 Hz (AC-3e) || 33 kW at 660...690 V AC 50 Hz (AC-3e) || 15 kW at 220...230 V AC 50 Hz (AC-3e) || 22 kW at 380...400 V AC 50 Hz (AC-3) || 25 kW at 415 V AC 50 Hz (AC-3) |
| Heat Dissipation | 4-5 W at 60 Hz for control circuit |
| Minimum Switching Current | 5 mA for control circuit |
|---|---|
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Control Circuit Voltage Limits | 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz |
| Control Circuit Type | AC 60 Hz |
| Insulation Resistance | > 10 MOhm for control circuit |
| Irms Rated Making Capacity | 900 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1 |
| Inrush Power In Va | 140-140 VA cos phi 0.75 (at 20 °C) || 160-160 VA cos phi 0.75 (at 20 °C) |
| Pole Contact Composition | 3 NO |
| Coil Technology | without built-in bidirectional peak limiting diode suppressor |
| Minimum Switching Voltage | 17 V for control circuit |
| Tightening Torque | power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hex (Allen key) 4 mm || power circuit 8 N.m EverLink BTR screw connectors 35-35 mm² hex (Allen key) 4 mm || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 |
| Auxiliary Contacts Type | mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1 |
| Hold-In Power Consumption In Va | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C) || 15-15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Motor Power Hp | 15 hp at 200/208 V AC 60 Hz for 3 phases motors || 15 hp at 230/240 V AC 60 Hz for 3 phases motors || 40 hp at 460/480 V AC 60 Hz for 3 phases motors || 40 hp at 575/600 V AC 60 Hz for 3 phases motors || 3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors |
| [Ui] Rated Insulation Voltage | power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1 || control circuit 600 V CSA || control circuit 600 V UL |
| Protective Cover | with |
Environment
| Product Certifications | GL || DNV || GOST || RINA || CSA || CCC || LROS (pending) || UKCA |
|---|---|
| Standards | IEC 60947-4-1 || EN 60947-5-1 || UL 508 || IEC 60947-5-1 |
| Net Weight | 1.4 kg |
| Ip Degree Of Protection | IP2X IEC 60529 || IP2X VDE 0106 |
| Operating Altitude | 0...3000 m |
| Fire Resistance | 850 °C IEC 60695-2-1 |
| Depth | 120 mm |
| Height | 122 mm |
|---|---|
| Climatic Withstand | IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat |
| Flame Retardance | V1 UL 94 |
| Mechanical Robustness | vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) |
| Quantity Per Set | set of 10 |
| Width | 55 mm |
Contractual warranty
| Warranty | 18 months |
|---|
Offer Sustainability
| Rohs Exemption Information | Yes |
|---|---|
| Environmental Disclosure | ENVPEP1503009EN |
| Pvc Free | Yes |
| Reach Regulation | Free of Substances of Very High Concern above the threshold |
| Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Circularity Profile | ENVEOLI1503009EN |
| Mercury Free | Yes |
|---|---|
| Sustainable Offer Status | Green Premium product |
| Toxic Heavy Metal Free | Yes |
| Reach Free Of Svhc | Yes |
| China Rohs Regulation | Pro-active China RoHS declaration (out of China RoHS legal scope) |
| Eu Rohs Directive | Compliant |

Accessories
Loading carousel layout...
Loading carousel layout...
Accessories
Loading carousel layout...
Loading carousel layout...
Similar Products
Loading carousel layout...
Loading carousel layout...
CAD
$413.98
/ EA
Lead times may vary. For an accurate estimate please contact us.
Looking to buy a large quantity?
To View Branch Inventory And Your Custom Pricing
CAD$413.98/ EA
Loading add to cart quantity...