TeSys Deca Contactor, 3 Pole, 50A, 110V AC Coil, Compact Design
Schneider Electric

Schneider Electric LC1D50AF7TQ TeSys Deca Contactor, 3 Pole, 50A, 110V AC Coil, Compact Design

  • MPN: LC1D50AF7TQ
  • PPN: SCH-LC1D50AF7TQ

CAD

$413.98

/ EA

Available to Order

Lead times may vary. For an accurate estimate please contact us.

Company Stock:

0

Looking to buy a large quantity?

To view product inventory

Spec sheet

Description

TeSys D contactor, 3 poles (3NO), for motor control applications up to 50A/690V AC-3/3e (7.5kW@400V). It provides a low consumption 110V AC 50/60 Hz coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Pack of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Documentation & Downloads

Specifications

Key Specifications

[Uc] Control Circuit Voltage
120 V AC 60 Hz
Range Of Product
TeSys Deca
Product Or Component Type
contactor
Utilisation Category
AC-1 || AC-2 || AC-3e || AC-4
Poles Description
3P
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz
Contactor Applicationmotor control || resistive load
RangeTeSys || TeSys Deca
[Ie] Rated Operational Current50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Device Short NameLC1D

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Power Dissipation Per Pole
3.7 W AC-3e || 3.7 W AC-3 || 9.6 W AC-1
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit
Mounting Support
rail || plate
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity
900 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating
100 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Connections - Terminals
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: rigid || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: rigid || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid
Operating Time
4...19 ms opening || 12...26 ms closing
Maximum Operating Rate
3600 cyc/h 60 °C
Mechanical Durability
6000000 cycles
Compatibility Code
LC1D
Overvoltage Category
III
Motor Power Kw
30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 Hz (AC-3) || 11 kW at 400 V AC 50 Hz (AC-4) || 22 kW at 380...400 V AC 50 Hz (AC-3e) || 25 kW at 415 V AC 50 Hz (AC-3e) || 30 kW at 440 V AC 50 Hz (AC-3e) || 30 kW at 500 V AC 50 Hz (AC-3e) || 33 kW at 660...690 V AC 50 Hz (AC-3e) || 15 kW at 220...230 V AC 50 Hz (AC-3e) || 22 kW at 380...400 V AC 50 Hz (AC-3) || 25 kW at 415 V AC 50 Hz (AC-3)
Heat Dissipation
4-5 W at 60 Hz for control circuit
Minimum Switching Current5 mA for control circuit
Auxiliary Contact Composition1 NO + 1 NC
Control Circuit Voltage Limits0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz
Control Circuit TypeAC 60 Hz
Insulation Resistance> 10 MOhm for control circuit
Irms Rated Making Capacity900 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1
Inrush Power In Va140-140 VA cos phi 0.75 (at 20 °C) || 160-160 VA cos phi 0.75 (at 20 °C)
Pole Contact Composition3 NO
Coil Technologywithout built-in bidirectional peak limiting diode suppressor
Minimum Switching Voltage17 V for control circuit
Tightening Torquepower circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hex (Allen key) 4 mm || power circuit 8 N.m EverLink BTR screw connectors 35-35 mm² hex (Allen key) 4 mm || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2
Auxiliary Contacts Typemechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va13-13 VA 60 Hz cos phi 0.3 (at 20 °C) || 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
Motor Power Hp15 hp at 200/208 V AC 60 Hz for 3 phases motors || 15 hp at 230/240 V AC 60 Hz for 3 phases motors || 40 hp at 460/480 V AC 60 Hz for 3 phases motors || 40 hp at 575/600 V AC 60 Hz for 3 phases motors || 3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
[Ui] Rated Insulation Voltagepower circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1 || control circuit 600 V CSA || control circuit 600 V UL
Protective Coverwith

Environment

Product Certifications
GL || DNV || GOST || RINA || CSA || CCC || LROS (pending) || UKCA
Standards
IEC 60947-4-1 || EN 60947-5-1 || UL 508 || IEC 60947-5-1
Net Weight
1.4 kg
Ip Degree Of Protection
IP2X IEC 60529 || IP2X VDE 0106
Operating Altitude
0...3000 m
Fire Resistance
850 °C IEC 60695-2-1
Depth
120 mm
Height122 mm
Climatic WithstandIACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame RetardanceV1 UL 94
Mechanical Robustnessvibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Quantity Per Setset of 10
Width55 mm

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1503009EN
Pvc Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Circularity Profile
ENVEOLI1503009EN
Mercury FreeYes
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach Free Of SvhcYes
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs DirectiveCompliant

Accessories

Loading carousel layout...

Accessories

Loading carousel layout...

Similar Products

Loading carousel layout...

CAD$413.98/ EA

Loading add to cart quantity...

banner

Need assistance?

We can help! Connect with our Sales Team Today!

",{"children":null,"id":"ahrefs web analytics"}])",{"children":null,"id":"ahrefs web analytics"}])